Board Connector, 14 Contact(s), 1 Row(s), Male, Right Angle, Press Fit Terminal,
CategoryThe connector    The connector   
File Size92KB,2 Pages
ManufacturerLumberg
Websitehttp://www.lumberg.com/zh/
Download Datasheet Parametric View All

367214 Overview

Board Connector, 14 Contact(s), 1 Row(s), Male, Right Angle, Press Fit Terminal,

367214 Parametric

Parameter NameAttribute value
MakerLumberg
Reach Compliance Codecompliant
Connector typeBOARD CONNECTOR
Contact to complete cooperationTIN OVER NICKEL
Contact completed and terminatedTIN OVER NICKEL
Contact point genderMALE
DIN complianceNO
Filter functionNO
IEC complianceNO
JESD-609 codee3
MIL complianceNO
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation methodRIGHT ANGLE
Installation typeBOARD
Number of rows loaded1
OptionsGENERAL PURPOSE
Terminal pitch5 mm
Termination typePRESS FIT
Total number of contacts14
UL Flammability Code94V-0
Base Number Matches1
RAST-5-Steckverbinder, Raster 5,0 mm
RAST 5 connectors, pitch 5.0 mm
Connecteurs RAST 5, pas 5,0 mm
3672
RAST-5-Messerleiste, abgewinkelt, mit Zwischenwänden und
obenliegender Verriegelung
1. Temperaturbereich
2. Werkstoffe
Kontaktträger
1
Kontaktmesser
3. Mechanische Daten
Kontaktmesser
Kontaktierung mit
6,3 x 0,8 mm nach DIN 46244
Steckverbindern 3611, 3615, 3623,
3626,
Steckverbindern nach RAST-5-
Standard
PA GF, V0 nach UL 94
CuZn, unternickelt und verzinnt
-40 °C/+120 °C
4. Elektrische Daten
Bemessungsstrom
10 A bei T
U
70 °C
250 V AC
Bemessungsspannung
2
IIIa (IEC)/2 (UL) CTI
250
Isolierstoffgruppe
2
Kriechstrecke
4,2 mm
Luftstrecke
4,2 mm
Isolationswiderstand
> 10
10
Ω
Bauteil glühdrahtbeständig (GWT 750 °C), Prüfung nach IEC 60695-2-11,
Beurteilung nach IEC 60335-1 (Flamme < 2 s)
nach DIN EN 60664/IEC 60664, CTI UL-Klassifizierung nach ANSI/UL 746A
1
2
Reg.-Nr. 135721
*a K = Kodierung
K = keying
K = codage
P = Positionierung
P = positioning
P = positionnement
V = Raum für Verriegelung
V = space for lock
V = emplacement pour verrouillage
*b Zwischenwand
partitioning
séparation
*c Maß für Presssitz auf der Leiterplatte
measure for press-fit on printed circuit board
mesure pour autofixation sur carte imprimée par pression
*d Lochbild in der Leiterplatte, von der Bauteilseite gesehen
printed circuit board layout, components side view
modèle de la carte imprimée, vue du côté à équiper
*e A = (P - 1) x 5 + (Z x 2,5)
P = Polzahl
P = poles
P = pôles
Z = Anzahl Zwischenwände (je 12 Kontakte mindestens 1 Zwischenwand)
Z = number of partitionings (at least 1 partitioning every 12 contacts)
Z = nombre de séparations (au moins 1 séparation tous les 12 contacts)
www.lumberg.com
05/2011
LCD display help (T6963C), please give me some advice!
Still a problem with the LCD display, still not solvedDetails are as follows:In the program, I set the shape and position of the attribute, and found that T6963C can correctly receive and process data...
yinxun DSP and ARM Processors
Discussion on reverse connection of MOS tube in protection circuit
The first discussion post is shown in Figure 1. A PMOS tube-involved overvoltage protection circuit uses a voltage regulator tube VT1 to stabilize the voltage at 5.1V. This way, the overvoltage protec...
shaorc Analog electronics
Video Topic 3——Proteus simulation ADC0809 digital voltmeter
A digital voltmeter software made with ADC0809+ microcontroller is PROTEUS...
lilong8470 MCU
Bor application of bluenrg-1
Slow power-on can easily cause a freeze, so consider using bor undervoltage protection. There is a line in the manual that says bor can be configured by software, but it does not specify the specifica...
南城北巷 ST - Low Power RF
A project to be established, please give your opinions
I am planning to develop a bridge anti-collision system, powered by solar energy. I am planning to use infrared sensors to cut off the warning that the ship is too high and issue a voice alarm. The pr...
hanxm Microcontroller MCU
4.2 kernel, serial port lost data, need help from experts
The application ClearCommError function prompts a CE_OVERRUN error. If (IntSubPndVal & (pHWHead->bErrINT)) in the driver's SL_GetInterruptType function is true, indicating that an error has occurred. ...
FionaLiu Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2762  1692  2301  884  1833  56  35  47  18  37 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号