EEWORLDEEWORLDEEWORLD

Part Number

Search

ZZL-HC-1510-05P06E-H52

Description
MIL Series Connector, 5 Contact(s), Steel, Tin Plated, Male, Solder Terminal, Receptacle
File Size69KB,1 Pages
ManufacturerAmphenol
Websitehttp://www.amphenol.com/
Download Datasheet Parametric View All

ZZL-HC-1510-05P06E-H52 Overview

MIL Series Connector, 5 Contact(s), Steel, Tin Plated, Male, Solder Terminal, Receptacle

ZZL-HC-1510-05P06E-H52 Parametric

Parameter NameAttribute value
Objectid1539295944
Reach Compliance Codeunknown
Other featuresSTANDARD:MIL-C-26500, CONTACT MATERIAL:NICKEL IRON, TIN PLATED
Body/casing typeRECEPTACLE
Connector typeMIL SERIES CONNECTOR
Contact completed and terminatedTIN
Contact point genderMALE
Coupling typeTHREADED
DIN complianceNO
IEC complianceNO
JESD-609 codee3
MIL complianceYES
Installation typeCABLE
OptionsHERMETIC
Shell surfaceTIN
Shell materialSTEEL
Termination typeSOLDER
Total number of contacts5
Hermetic MIL-C-26500 Connectors
hermetically sealed
Amphenol
®
/Pyle
®
is an experienced supplier of highly reliable her-
metic connectors for the aircraft industry. Amphenol’s ZZL and ZZB
series of hermetic receptacles are designed to the requirements of
MIL-C-26500, and are available in tin-plated cold-rolled steel shells
and gold-plated nickel-iron alloy contacts. Other material variations,
including stainless steel, are available.
Hermetic receptacles are available in shell sizes 8, 10, 12, 14, 16, 18,
22, 24 and 28. The hermetic series is offered in a variety of receptacle
shell styles, which include solder mount, square flange and “D” hole
mount. These connectors can be ordered with either eyelet, solder-
well or printed circuit tail pin contacts.
Consult Amphenol, Sidney, NY for more information on hermetic con-
nectors, and for optional connector designs.
Amphenol
®
/Pyle
®
How to Order Designation for Hermetic Connectors
Sample ordering number:
ZZL – HC – 14
12 – 03
P
06
W – H45
Special Modifications
H45 – 304L stainless steel shell
H52 – Tinned termination tails
H56 – Same as standard;
gold contacts
H77 – 304L stainless steel shell,
Inconel contacts
H127 – Same as H125 except 304L
stainless steel shell
H146 – 303 stainless steel shell, 100
microinch gold
H152 – 304L stainless steel shell with
individual beads, loose seals
H177 – 303 stainless steel shell, loose
seals
H181 – Tin plated contacts
Contact Style
E – designates eyelet
W – designates solderwell
Consult Amphenol, Sidney, NY for
ordering information of printed circuit
tail contacts.
Series Designation
ZZL – Threaded Coupling
ZZB – Bayonet Coupling
Class
HC – Denotes Hermetic Class
Shell Style
14 – Solder Mount Receptacle
15 – Single Hole Mounting Receptacle
17 – Square Flange Receptacle
Shell Size
8, 10, 12, 14, 16, 18, 22, 24, 28
Insert Arrangement
See inserts labeled with an “H” on page 4.
Contact Type
P denotes male pin contacts with standard gold plate
Alternate Key Position
06, 07, 08, 09, 10 (omit for normal)
(See page 4)
26
What speed can the FSMC of STM32 reach? Who has tested it and how was it tested?
I use B modeSystem 72Mdata retention is set to 1.The low level pulse width of HTCK writing data is about 50nS when observed with an oscilloscopeIs it because my method is not appropriate, or is it jus...
linxiuhua stm32/stm8
How should I proceed?
In a small company, I have a ready-made gprs module and a rabbit series microcontroller. The embedded program is modified on the source code and some functions are added, such as AT command sending. T...
hxuan Embedded System
[Xianji HPM6750 Review] Testing the Ethernet Controller ENET
HPM6750 has 2 Gigabit Ethernet controllers. The MINI board leads to a RMII interface Ethernet controller HPM_ENET1 PIN. There is a lwip tcpecho routine in the SDK. The default PHY used is DP83848. I r...
xiashuang Domestic Chip Exchange
Help: The no-load current of LM5122 is very large and it is always running at full duty cycle. What could be the reason?
Help: The no-load current of LM5122 is very large and it is always running at full duty cycle. What could be the reason?...
blink Analogue and Mixed Signal
Waveform Amplitude Step
What methods can be used to achieve a 0.1V step for the wave amplitude (between 0 and 5V)?...
吖辉 Analog electronics
Designing a compact, efficient and high-performance multi-parameter patient monitor
Continuously measuring patient vital signs such as heart rate, respiratory rate and blood oxygen saturation (SpO2) is critical to providing effective care, and the ability to measure these signs simul...
alan000345 TI Technology Forum

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 303  2183  786  1055  2393  7  44  16  22  49 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号