BK/ABC-6-R

Description
fuse cerm 6A 250vac 125vdc 3ab
CategoryCircuit protection    Circuit protection   
File Size205KB,2 Pages
ManufacturerEaton
Environmental Compliance
Download Datasheet Parametric View All

BK/ABC-6-R Overview

fuse cerm 6A 250vac 125vdc 3ab

BK/ABC-6-R Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerEaton
package instructionROHS COMPLIANT
Reach Compliance Codeunknown
Other featuresRATED BREAKING CAPACITY AT 125 VDC: 10000 A
Fusing characteristicsFAST
body height31.75 mm
Body length or diameter6.35 mm
Circuit protection typeELECTRIC FUSE
Joule integral nominal31 J
Manufacturer's serial numberABC
Installation featuresINLINE/HOLDER
method of packingBOX
physical size6.35mm x 31.75mm
Rated breaking capacity200 A
Rated current6 A
Rated voltage (AC)250 V
Rated voltage (DC)125 V
GuidelineCSA; UL
surface mountNO
Terminal shapeEND CAP
1
4
” x 1
1
4
” Glass Tube Fuses
ABC Series, Fast-Acting, Ceramic Tube
Description
• Fast-acting, ceramic tube
• Optional axial leads available
1
4
” x 1
1
4
” (6.4 x 31.7mm) physical size
• Ceramic tube, nickel-plated brass endcap construction
• UL Listed product meets standard 248-14
ELECTRICAL CHARACTERISTICS
% of Amp Rating
Opening Time
100%
4 Hours Minimum
135%
60 Minutes maximum
200%
120 Seconds Maximum
Dimensions - mm
Drawing Not to Scale
Agency Information
• UL Listed Guide JDYX & File E19180
• UL Recognition Guide JDYX2 & File E19180
• CSA Certification: Class No: 1422-01 & 1422-30,
File 53787
Environmental Data
• Shock:
1
4
A - 30A – MIL-STD-202, Method 213,
Test Condition J
• Vibration:
1
4
A - 30A – MIL-STD-202, Method 204,
Test Condition C (Except 5g, 500Hz)
Ordering
• Specify packaging, product and option code
Voltage
Ratings
Vac
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
Vdc
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
Vac Interrupting
Ratings* (amps)
250
125
35
10,000
35
10,000
35
10,000
35
10,000
100
10,000
100
10,000
100
10,000
100
10,000
200
10,000
200
10,000
200
10,000
200
10,000
200
10,000
200
10,000
750
10,000
750
10,000
400
1000
400
1000
200
1000
200
1000
* Interrupting ratings measured at 70% - 80% power factor on AC. The interrupting ratings for 18A and 20A were measured at 85% - 95% power factor on AC. The
interrupting ratings for 25A and 30A were measured at 89% power factor on AC.
** Typical DC cold resistance measured at <10% of rated current.
† Typical melting I2t measured at listed interrupting rating and rated voltage.
‡ Typical voltage drop measured at 25°C±3°C ambient temperature at rated current.
‡‡ CSA approvals for 25A and 30A are at 125Vac - IR 1000A and 125Vdc - IR 400A (IR 1000A at 75Vdc)
Part
Number
ABC-
1
4
-R
ABC-
1
2
-R
ABC-
3
4
-R
ABC-1-R
ABC-1-
1
2
-R
ABC-2-R
ABC-2-
1
2
-R
ABC-3-R
ABC-4-R
ABC-5-R
ABC-6-R
ABC-7-R
ABC-8-R
ABC-10-R
ABC-12-R
ABC-15-R
ABC-18-R
ABC-20-R
ABC-25-R
ABC-30-R
Vdc Interrupting
Ratings (amps)
125
75
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
10,000
400
1000
400
1000
Specifications
Typical
DC Cold
Resistance (Ω)**
2.950
0.587
0.300
0.1950
0.131
0.0890
0.061
0.047
0.031
0.026
0.021
0.016
0.014
0.011
0.0068
0.00553
0.00465
0.00366
0.0028
0.002225
Typical
Pre-Arc
I
2
t AC
0.0020
0.0390
0.1450
0.4310
1.1630
2.1670
4.4670
6.55
22.28
32.83
58
109.33
116.5
208.8
133.3
200.2
400
550.8
839.3
1429
Typical
Voltage
Drop (V)
0.35
0.41
0.32
0.3
0.28
0.31
0.23
0.14
0.17
0.22
0.19
0.17
0.19
0.15
0.1
0.1
0.1
0.1
0.09
0.09
Agency Approvals
UL UR CSA
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
‡‡
X X
‡‡
0613
BU-SB13635
Page 1 of 2
Data Sheet 2000
Find UHF high frequency chip manufacturers
Does anyone know which UHF high-frequency chip manufacturers there are? Desheng has a WPM-100 model with good sound quality. Does anyone know which chip solution it uses?...
智能物联 Download Centre
I want to use the receive button to control whether to receive data. How can I adjust the relationship between it and ReadPortThread? ?
void CMySerialFourDlg::OnReceive() { // TODO: Add your control notification handler code here ::MessageBox(NULL,_T("Datas will be received!"),_T("Notice!"),MB_ICONEXCLAMATION); } DWORD WINAPI ReadPort...
axiaoyeah Embedded System
About Multisim13.0 simulation issues.
I want to build this circuit into the software to get the output waveform. As the input involves the rotation of the motor, I want to use the existing [/color][color=rgb(45, 100, 179)][url=http://jump...
西里古1992 Embedded System
Classic pure data GSM/GPRS transmission module-M590
M590 Size: 28mm*24mm*11mm The world's first single-chip GPRS module Low power consumption: standby power consumption 2.5MA Wide temperature range: -40—80 Supports CMUX function of the serial port Open...
dingxy Embedded System
The serial port tool shows nothing! ! ! !
My serial port tool cannot display the U-BOOT option menu that I modified. There is nothing. When I do the i2c and LCD experiments, there is nothing on the serial port tool! But the uart experiment is...
longdandan Embedded System
Always be grateful
【Source】IT Department: Wang KunTime always slips away without people noticing. More than 20 years are like a movie, seemingly long, but passing by in the blink of an eye. Although it is not exciting, ...
chiplights Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1733  276  1203  1975  2204  35  6  25  40  45 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号