EEWORLDEEWORLDEEWORLD

Part Number

Search

ECEC2FP151BB

Description
CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 315V, 150uF, THROUGH HOLE MOUNT, RADIAL LEADED
File Size177KB,14 Pages
ManufacturerPanasonic
Websitehttp://www.panasonic.co.jp/semicon/e-index.html
Environmental Compliance  
Download Datasheet Parametric View All

ECEC2FP151BB Overview

CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 315V, 150uF, THROUGH HOLE MOUNT, RADIAL LEADED

ECEC2FP151BB Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Objectid2014537952
package instruction,
Reach Compliance Codeunknown
ECCN codeEAR99
capacitance150 µF
Capacitor typeALUMINUM ELECTROLYTIC CAPACITOR
dielectric materialsALUMINUM (WET)
JESD-609 codee3
leakage current0.652112 mA
Manufacturer's serial numberUP
Installation featuresTHROUGH HOLE MOUNT
negative tolerance20%
Number of terminals2
Maximum operating temperature85 °C
Minimum operating temperature-25 °C
Package shapeCYLINDRICAL PACKAGE
polarityPOLARIZED
positive tolerance20%
Rated (DC) voltage (URdc)315 V
ripple current1110 mA
surface mountNO
Delta tangent0.15
Terminal surfaceTin (Sn)
Terminal shapeSNAP-IN
Aluminum Electrolytic Capacitors/UP
Snap-in Type
Series:
UP
n
Features
Type :
TS
Endurance: 85°C 2000 h
Dia.
φ20
mm
Length 20 mm
Smoothing circuits, AC adaptor,
Country of Origin
Japan
Malaysia
U.S.A (ii)
(ii) Regarding USA product,
,
Please check ACOM s
Catalog.
-25 to + 85°C
315 to 450 V .DC
33 to 820 µ F
±20 % (120Hz/+20°C)
n
Recommended Applications
n
Specifications
Category temp. range
Rated W.V. Range
Nominal Cap. Range
Capacitance Tolerance
DC Leakage Current
-40 to + 85°C
16 to 250 V .DC
120 to 68000 µ F
3√CV (µA) max. after 5 minutes application of rated working voltage at +20°C.
C:Capacitance(µF) V: W.V. (V.DC)
Please see the attached standard products list
tan
δ
Frequency (Hz)
50
60
100
120
500
1k
10k to
Frequency Correction
0.95
0.99
1.00
1.05
1.08
1.15
Factor for Ripple Current
Correction Factor
16 to 100V 0.93
0.80
0.95
1.00
1.20
1.25
1.40
160 to 450V 0.75
After 2000 hours application of DC voltage with specified ripple current (< rated DC working
voltage) at +85°C, the capacitor shall meet the following limits.
Capacitance change ±20 % of initial measured value
Endurance
tan
δ
<
200 % of initial specified value
DC leakage current
<
initial specified value
Shelf Life
After storage for 1000 hours at +85±2
°C
with no voltage applied and then being stabilized
at +20
°C,
capacitors shall meet the limits specified in Endurance.(With voltage treatment)
n
Dimensions in mm (not to scale)
(10.0) 2-φ2.0±0.1
10.0±0.1
Polarity bar
φD+1.0
max
Sleeve
Vent
L+2.0 max
Recommended PWB piercing plan
i
0.8
-
0.1
+0.2
Terminal
i
4.0±0.5
2.0 max
(t= 0.8)
(3.5)
Bottom of can
1.5 ± 0.2
Standard terminal type does not require
terminal trimming process.
i6.3
mm is available upon request.
Design, and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase
and / or use. Should a safety concern arise regarding this product,please be sure to contact us immediately.
Mar. 2005
EE128
To develop more efficient grid power, you must know these
[color=#000][color=rgb(62, 62, 62)][align=left]智能电网旨在通过电源实现通信,以提高电网效率。实现这一目标的方法是确保连接至电网的设备不仅可为目标功能实现高电源效率,而且还能以最高效的方式使用电能,从而最大限度减少峰值功耗,降低整体平均用电。 [/align] [align=left]为了达到该效率标准,需要使用低功耗 M2M 通信系统。该系统的核心是...
okhxyyo Analogue and Mixed Signal
The mobile version of the forum looks good
The mobile version of the forum looks good...
Sur Talking
Have you ever used a card machine to print?
Have you ever used a card printer to print? Or can you tell me how to use a card printer to print? Is it the same as normal printing? Is there a unified SDK for card printers?...
jianuo Embedded System
PLC wireless control relay design scheme
[i=s]This post was last edited by dontium on 2015-1-23 13:08[/i] ——Keywords: relay signal wireless transmission passive signal wireless control module ⒈Project Background A power plant in North China ...
bwm12315 Analogue and Mixed Signal
[Repost] Digital multimeter self-test battery voltage method
Popular digital multimeters are generally powered by 9V laminated batteries. When it is necessary to measure the voltage of the power supply itself, it is generally done with other instruments or afte...
zdr MCU
Problems that should be paid attention to in PLC application
PLC is a control device specially designed for industrial production. Usually, no measures need to be taken to use it directly in an industrial environment. However, when the production environment is...
totopper Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 149  2445  20  2238  306  3  50  1  46  7 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号