Municipal, Industrial and Environmental Applications
LT 5 & 7 Pressure Transducers are non-submersible hydrostatic pressure
transducers specifically designed for demanding industrial applications
where the primary criteria are reliability and economy.
Applications
Non-Submersible Tank Level
Liquid Line Pressure
Pump Control
Construction Bypass Pumping
Dewatering
Features
Standard
0.25% FSO Accuracy
316 Stainless Steel Body
One Year Warranty
Pre-calibrated Pressure Ranges
Optional
0.10% FSO Accuracy
Titanium Body
Two Year Warranty
Custom Pressure Ranges
Intrinsically Safe
Lightning Protection
TE CONNECTIVITY SENSORS
/// MEAS PRESSURE SERIES TRANSDUCERS LT5 & LT7
10/2017
Page 1
MEAS PRESSURE SERIES TRANSDUCERS LT5 & LT7
Specifications
STATIC PERFORMANCE
Static Accuracy
(combined effects of non-linearity,
hysteresis and repeatability, best fit
straight line method)
Standard - 0.25% FSO
Optional - 0.10% FSO
+0.0001% FS
316 SS or Titanium; FKM;
Polyurethane or ETFE
0 to 50ºC
±0.1% FSO/ºC
-20 to 60 ºC
IP 68, NEMA 6P
BFSL method
For absolute/sealed reference min. range 0-15 PSI
Resolution
ENVIRONMENTAL
Wetted Materials
Compensated Temp Range
Thermal Error
(maximum allowable deviation from the
Best Fit Straight Line due to a change in
temperature)
Operating Temp Range
Protection Rating
When attached to polyurethane cable
Only for Electrical Connection options “A” & “D”
with Cable Type option “A”; or Electrical
Connection options “B” & “F” with Cable Type option “B”
0-5V, 0-2.5V, 0-4V
4-20
0-10V
1.5-7.5V
For mA output, for VDC output
For ranges < 5 ft. (1.5m) H
2
O,
only 4-20mA output is available
ELECTRICAL
Excitation
9-28V
–
VDC output
9-28V
–
mA output
15-28V
–
VDC output
10-28V
–
VDC output
20 mA max, 3.5 mA max
Standard - 4-20mA
Optional - 0-4 VDC, 0-5 VDC,
0-2.5 VDC, 0-10 VDC, 1.5-7.5 VDC
±0.25 mA for mA output
< 0.25 VDC for VDC output
See loop diagram for mA output
20 ohm for VDC output
100 mega ohm at 50 VDC
Polarity, surge/shorted output
Standard
–
WEEE/RoHS, CE
compliant
Optional
–
UL, CUL, and FM
PHYSICAL
Approximate Weight
Cable Jacket Material
Cable Pull Strength
Cable Number of Conductors
Cable Conductor Size
Cable Seal
0.44 lbs. (198 g) transducer
0.05 lbs./ft. (79 g/m) cable
PVC Jacket, Standard - Polyurethane
Optional - ETFE
200 lbs. (90 kg)
4
22 AWG
Molded Polyurethane
FKM Gland
For polyurethane cable
For ETFE cable
EN 61326-1:2013 and 61326-2-3:2013
Waste from Electrical and Electronic Equipment
(WEEE) and Restrictions on the use of Hazardous
Substances (RoHS)
Class I, II, III, Div. 1, Groups A,B,C,D,E,F,&G
Input Current
Output
Zero Offset
Output Impedance
Insulation Resistance
Circuit Protection
CERTIFICATIONS
LIGHTNING PROTECTION
(power supply needs to be limited to 150mA to avoid lock up of the gas tube after a suppression event)
>1,000 Operations
Life Expectancy
Peak Clamping Voltage
Response Time
Shunts
36 Volts
<10 nsecs
20,000 Amperes
TE CONNECTIVITY SENSORS
/// MEAS PRESSURE SERIES TRANSDUCERS LT5 & LT7
10/2017
Page 2
MEAS PRESSURE SERIES TRANSDUCERS LT5 & LT7
Dimensions
Electrical Termination / Loop Resistance
ELECTRICAL TERMINATION
22AWG CONDUCTORS IN A SHIELDED CABLE WITH VENT TUBE
4-20 mA
0-5 VDC
ALL
RED
BLACK
RED
BLACK
WHITE
DRAIN WIRE
+ EXCITATION
- EXCITATION
+ EXCITATION
- EXCITATION
+ SIGNAL
SHIELD
Standard Pressure Ranges for 0.25% Accuracy
Pressure Range
3
5
5
3
5
3
5
7
9
LT 5, 7 Vented
X
X
X
X
X
X
X
X
N/A
N/A
N/A
axi u
of 3
LT 5, 7 Sealed
N/A
N/A
X
X
X
X
X
X
X
X
X
PSI. Mi i u
LT 5,7 Absolute
N/A
N/A
N/A
X
X
X
X
X
X
X
X
NOTE: O er old optio is li ited to a
sealed/a solute refere e is - 5 PSI
ra ge for +/- .
% ith
TE CONNECTIVITY SENSORS
/// MEAS PRESSURE SERIES TRANSDUCERS LT5 & LT7
10/2017
Page 3
MEAS PRESSURE SERIES TRANSDUCERS LT5 & LT7
Ordering Information
TRANSDUCER
L
T Submersible Level Transducer
↓
↓
PRESSURE PORT
5
¼” –
18 Male NPT Fitting
7
½” –
14 Male NPT Fitting
↓
OUTPUT
8
4
–
20 mA
1
0
–
2.5 VDC
2
0
–
4 VDC
3
0
–
5 VDC
4
0
–
10 VDC
5
1.5
–
7.5 VDC
G
4-20 mA w/Lightning
A
0-2.5 VDC w/Lightning
B
0-4 VDC w/Lightning
C
0-5 VDC w/Lightning
D
0-10 VDC w/Lightning
E
1.5-7.5 VDC w/Lightning
↓
CABLE TYPE
A
Polyurethane
B
ETFE
C
PVC jacket
↓
ACCURACY
B
±0.25% FSO
R
±0.25% FSO with Cal Report
A
±0.10% FSO
S
±0.10% FSO with Cal Report
↓
INTRINSIC SAFETY APPROVALS
B
UL, FM & CUL (Cable Type A, B, or C Only)
D
None
↓
WARRANTY
1
A
Standard one year Warranty
B
Custom label one year Warranty
J
Extended two year Warranty
K
Custom Label extended two year Warranty
↓
MATERIAL
S
Stainless Steel
T
Titanium
↓
ELECTRICAL CONNECTION
A
Overmold (Cable Type A Only)
B
Gland Seal
(Cable Type “A” or “B” Only)
D
Overmold w/ ½” –
14 NPT Conduit (Cable Type A Only)
F
Gland Seal w/ ½” –
14 NPT Conduit
(Cable Type “A” or “B” Only)
1
Strain-relieved cable with flying leads - standard (Cable Type C Only)
2
PVC conduit strain relief
(Cable Type C Only)
↓
PRESSURE RANGE
x
x
x
Refer to chart page 4
↓
↓
↓
LABEL UNITS
P
PSI M mH2O F Ft. H2O
↓
PRESSURE REFERENCE
A
Absolute
G
Vented Gage
S
Sealed Gage
↓
CABLE LENGTH (FT)
x
x
x
Cable length in feet
↓
↓
↓
L
T
1
Contact Measurement Specialties if private labeling is required.
NORTH AMERICA
Measurement Specialties, Inc.
a TE Connectivity Company
Tel 800-522-6752
customercare.hmpt@te.com
EUROPE
Measurement Specialties (Europe), Ltd.,
A TE Connectivity Company
Tel 800-440-5100
customercare.dtmd@te.com
ASIA
Measurement Specialties (China), Ltd.,
a TE Connectivity Company
Tel 0400-820-6049
customercare.shzn@te.com
TE.com/sensorsolutions
Measurement Specialties, Inc., a TE Connectivity company.
Measurement Specialties (MEAS), American Sensor Technologies (AST), TE Connectivity, TE Connectivity (logo) and EVERY CONNECTION COUNTS are trademarks. All other logos, products
and/or company names referred to herein might be trademarks of their respective owners.
The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes no
warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity‘s obligations shall only be as set forth in TE Connectivity‘s Standard Terms and
Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product.
Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application.
[size=4] Today, I started the [b][color=#ff0000]Learn MicroPython on ESP32 with me[/color][/b] activity, which will lead everyone to learn the usage of MicroPython on ESP32 from scratch. ESP32 is curr...
[i=s]This post was last edited by ljj3166 on 2015-9-15 00:06[/i] It is planned to save the power data when the power is turned off. I have looked through all the C809 devices and found that there is n...
[color=black]Measuring power supply ripple itself is a skill. Figure 1 shows an example of improper use of an oscilloscope to measure power supply ripple. Several mistakes were made in this example. T...
1394 is being squeezed hard by USB in the PC and peripheral markets, but there are signs of new life in the consumer electronics (CE) market, according to In-Stat. The high-tech market research compan...
Abstract: In order to generate a stable excitation signal, the design of a digital frequency synthesizer is implemented on FPGA using Verilog hardware language. The design includes accumulator, wav...[Details]
This controller uses PIC16C54 single-chip microcomputer as the controller, and it is very easy to use: just connect a telephone line to the loudspeaker through the controller, and you can rem...[Details]
Investment in
the
medical device
industry has been on the rise in recent years. In the past two years, venture capital for medical devices has almost doubled, reaching $4 billion in 2007. Fr...[Details]
Problems such as the depletion of natural resources, air pollution, traffic congestion, and rising fossil fuel prices have forced societies and individuals to seek alternative means of transportati...[Details]
Motors, especially those with brushes, generate a lot of noise. This noise must be dealt with if the appliance is to meet the requirements of EMC standards. The means to solve EMC are nothing more ...[Details]
Recently, news came from the certification department that the photovoltaic grid-connected inverter of Samil New Energy Co., Ltd. (hereinafter referred to as "Samil New Energy") has once again obta...[Details]
Introduction
Nowadays, people pay more and more attention to the security alarm system, and people have higher and higher requirements for the functions and performance of the alarm. This paper prop...[Details]
Analysis of the three core aspects of digital TV transmission standards
According to the differences in regionality, transmission method and modulation method, the transmission method needs to...[Details]
LED is the abbreviation of the English word. Its main meanings are: LED = Light Emitting Diode, a solid-state semiconductor device that can convert electrical energy into visible light. It can dire...[Details]
Every time I go home and walk up the stairs, I am always scared. The corridor lights are often broken, and no one changes the bulbs, or they are not smart enough and need to be operated manually. E...[Details]
The capacity of a battery depends on the amount of charge and discharge, in addition to some factors of the battery itself. Obviously, if the charge and discharge of the battery can be recorded all...[Details]
Power supply is often the most easily overlooked link in the circuit design process. In fact, as an excellent design, power supply design should be very important, which greatly affects the perfor...[Details]
DigRF
is
poised to replace the two main forms of data communication paths between RF and baseband semiconductor devices:
analog
signaling, and proprietary digital signaling (paralle...[Details]
1. Introduction
Modern modular machine tools are equipped with a large number of electronic devices to meet the requirements of processing accuracy, processing speed, etc. If the conventional ...[Details]
As a new type of centralized and decentralized elevator control system, serial communication has been widely used in China. Compared with the previous centralized and unified control system, each s...[Details]