SPECIFICATIONS
DISPLAY
Digits:
Type:
Polarity:
Decimal Points:
Overrange:
Hold:
Ranges:
Configuration:
Protection:
Impedance:
Accuracy:
Conversion Rate:
Normal Mode Rejection:
Common Mode Range:
Common Mode Rej.:
Zero Adjustment:
Warmup:
Temperature Coeff.:
3 ½ digits (±1999 counts)
0.8” (20.3 mm) LED
automatic, “-” displayed.
3 position, user selectable
three lower order digits blank for
inputs >1999 & < -1999
display hold function is standard
ORDERING INFO
PART NUMBER
METER COLOR
METER INPUT
DK851A ...................................... RED ............................................200mV
DK852A ...................................... RED .................................................. 2V
DK853A ...................................... RED ................................................ 20V
DK951A ..................................... GREEN ..........................................200mV
DK952A .................................... GREEN ................................................ 2V
DK953A .................................... GREEN .............................................. 20V
INPUTS
±200.0 mV, +/-2.000 V, +/-20.00 VDC
bipolar, differential
±350 VDC, (±100 VDC on 200 mV range)
>1 MΩ, (>10 MΩ on 200 mV range)
±(0.05% FS +1 counts)
3 per second
>30 dB @ 60 Hz
±1V DC
>86 dB
automatic
10 minutes typical
±100 ppm per °C typical
-10 to 50 °C
-40 to 75 °C
+5V DC (± 5%) 180 mA @ 5 V
snap-in panel mount or clamp and gasket
13 pin male connection
ACCESSORIES
J4C13 ..................................................... 13 Pin Connector / Wire Assembly
.
PW2-5 ....................................... Regulated 120V AC to 5V DC Power Supply
CVC ..............................................................................................Calibrator
PERFORMANCE
ENVIRONMENT
Operating Range:
Storage Range:
POWER SUPPLY
MOUNTING
(included)
CONNECTION
C-TON I
NdusTrIes
• PO Box 11746 • Memphis, TN 38111 • USA (603) 471-0158 •
emaIl
:
INfO
@
CTONINdusTrIes
.
COm
LED Digital Panel Meters
Specifications Installation and Operating Instructions
Large 3½ Digit LED Digital Panel Meter
DK800/900
DIMENSIONS
WIRING
PIN #
1
2
3
4
5
6
7
8
9
10
11
12
13
DESCRIPTION
+5V POWER SUPPLY
NEGATIVE SUPPLY
INHI
INLO
DECIMAL COMMON
DECIMAL 000.0 WHEN CONNECTED TO DECIMAL COMMON
DECIMAL 00.00 WHEN CONNECTED TO DECIMAL COMMON
DECIMAL 0.000 WHEN CONNECTED TO DECIMAL COMMON
NO CONNECTION REQUIRED
NO CONNECTION REQUIRED
DISPLAY HOLD WHEN CONNECTED TO +5V
NO CONNECTION
NO CONNECTION
* Note: Pins 2 &4 should be tied together for proper operation