EEWORLDEEWORLDEEWORLD

Part Number

Search

805-002-16NF23-12HB

Description
Circular Connector
CategoryThe connector    The connector   
File Size2MB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

805-002-16NF23-12HB Overview

Circular Connector

805-002-16NF23-12HB Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
Objectid7093092231
Reach Compliance Codenot_compliant
ECCN codeEAR99
YTEOL8.6
Other featuresSTANDARD: MIL-DTL-38999, POLARIZED
Back shell typeSOLID
Body/casing typePLUG
Connector typeMIL SERIES CONNECTOR
Contact point genderFEMALE
Number of contacts12
Contact size12
Coupling typeTHREADED
rotation75
empty shellNO
Environmental characteristicsENVIRONMENT/FLUID RESISTANT
Filter functionNO
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE
Maximum operating temperature175 °C
Minimum operating temperature-65 °C
OptionsGENERAL PURPOSE
polarizationB
Shell materialALUMINUM ALLOY
Housing size23
Termination typeCRIMP
Total number of contacts12
Unique insertion number23-12
Series 805 Mighty Mouse
Triple-Start ACME Thread Plug
805-001 and 805-002 Ordering Information
Two Shell Styles:
Integral platform for
direct shield attachment using Band-
Master™ ATS termination system, or
accessory thread for attaching a strain
relief.
EMI Ground Spring
Achieves low shell-
to-shell resistance. This nickel-plated
beryllium copper spring enables the
Series 805 to meet greater than 60 dB
shielding effectiveness from 100 MHz
to 15 GHz.
How To Order
Sample Part Number
Series (See Table I)
Shell Style
H
805-001
Plug with Banding Platform
805-002
Plug with Accessory Thread
Series 805
Shell Material and Finish
Shell Size - Insert
Arrangement
Contact Type
With contacts
P
= Pin
S
= Socket
Shell Key Positions
(See Table II)
A
= Normal
Ratchet Design for Secure Coupling
Series 805 connectors feature a spring
mechanism in the coupling nut that
locks into radial teeth on the plug
barrel. This feature allows the Series 805
to stay mated even when under high
vibration, without the need for safety
wire or torque tools.
805-001
805-001
= Plug with Banding Platform
805-002
= Plug with Accessory Thread
-16
= Plug Connector with Ratcheting Anti-Decoupling Mechanism
C
= Aluminum / Black Anodize (Non-Conductive); RoHS Compliant
M
= Aluminum / Electroless Nickel; RoHS Compliant
MT
= Aluminum / Nickel-PTFE RoHS Compliant
NF
= Aluminum / Cadmium with Olive Drab Chromate
ZN
= Aluminum / Zinc-Nickel with Olive Drab Chromate
ZNU
= Aluminum / Zinc-Nickel with Black Chromate
Z1
= Stainless Steel / Passivated; RoHS Compliant
See Contact Arrangements Page H-2
Without contacts
A
= Pin Connector, less contacts
B
= Socket Connector, less contacts
-16
M
8-4
P
A
With 30 AWG Crimp Barrel
G
= #23 Pin
H
= #23 Socket
Connector with contacts are supplied with signal and/or power crimp contacts.
These contacts are not installed.
Coaxial contacts and non-standard signal contacts are ordered separately.
B
= Pos. B
C
= Pos. C
D
= Pos. D
E
= Pos. E
F
= Pos. F
Table I: Series
Key Position
Normal (A)
B
C
D
E
F
A
Table II: Key Positions
Key Rotation
B
210°
210°
230°
275°
275°
210°
B° A°
150°
75°
95°
140°
75°
95°
Dimensions in Inches (millimeters) are subject to change without notice.
© 2014 Glenair, Inc.
Series 80 Mighty Mouse
U.S. CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC.
1211 AIR WAY
GLENDALE, CA 91201-2497
818-247-6000
FAX 818-500-9912
www.glenair.com
H-8
E-Mail: sales@glenair.com
Please tell me how to connect MMA7455 and 51 microcontroller
I need to use MMA7455 to measure angles. The microcontroller needs 51. 51 is 5V. 7455 is 3.3V. How to connect it without damage?...
w260743374 MCU
Home IoT access control part
The entire access control part is like using a 430 chip as a companion chip. The program flow on the 430 is as shown aboveSome program codes are in the attachmentFinally, let me share an example of TI...
zca123 DIY/Open Source Hardware
Questions about the ADC12 module
#include#include "BoardConfig.h" #define uint unsigned int #define uchar unsigned char uchar static adc_flag=0; uchar static count=0; void int_clk() { uchar i; BCSCTL1=~XT2OFF; BCSCTL2|SELM1+SELS; do ...
chen502 Microcontroller MCU
Share a GCC programming problem with everyone##
Question 1: What is the range of the double type?double +/- 1.79769e+308What does the e in here mean?Is it 10 to the power of 308 or 2.818 to the power of 308?Problem 2: Super Least Common Multiple[co...
37°男人 Programming Basics
Need help, CCS3.3 programming F2812
Hello everyone, I just started to learn DSP and completed the hardware simulation of F2812. Now I want to try to use CCS3.3 to burn the firmware program to F2812. I encountered the following problems:...
jiangkeqin_sy DSP and ARM Processors
CPU\memory\task\abnormal monitoring in vxworks environment
Task running status monitoring The status information of a task during running mainly includes task name, task status, current CPU usage ratio, task priority, etc. The Spy tool of VxWorks uses the int...
h_g_y Real-time operating system RTOS

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1241  1011  568  491  2109  25  21  12  10  43 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号