EEWORLDEEWORLDEEWORLD

Part Number

Search

2127-S3-13-30

Description
Card Edge Connector, 54 Contact(s), 2 Row(s), Female, Straight, Solder Terminal
CategoryThe connector    The connector   
File Size151KB,2 Pages
ManufacturerECS
Websitehttp://www.ecsxtal.com/
Download Datasheet Parametric View All

2127-S3-13-30 Overview

Card Edge Connector, 54 Contact(s), 2 Row(s), Female, Straight, Solder Terminal

2127-S3-13-30 Parametric

Parameter NameAttribute value
Objectid1970370885
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresPOLARIZED
Connector typeCARD EDGE CONNECTOR
Contact point genderFEMALE
DIN complianceNO
Filter functionNO
IEC complianceNO
MIL complianceNO
Mixed contactsNO
Installation methodSTRAIGHT
Installation typeBOARD
Number of rows loaded2
OptionsGENERAL PURPOSE
Terminal pitch3.18 mm
Termination typeSOLDER
Total number of contacts54
UL Flammability Code94V-0
CC
S
2100 Series Card Edge Connector
.125” X .250” Contact Spacing
Features
Extra large chamfered entry
Conforms to Bell-core spec TR-TSY-00078
Extended card scoops available
Replaceable contacts
Molded in polarization available between
contact, or on contact position.
• De-population of contacts per
customer specification.
• Available in selective gold plate at contact point
• Many other custom options available, including,
but not limited to:
• Single or Both Ends Open
• Shorting Contacts
Specifications
Insulator Material: Glass filled polyester, type PBT,
94 V-O, UL Rated.
Contact Material: Phosphor Bronze Alloy
Contact Plating: Gold and/or Tin over .000050” Nickel,
(See Contact Plating Options).
Current Rating:
3 amp at 30°C
Contact Resistance:
Contact to Daughter Card:
10 m
W
max.
Insulation Resistance:
5000 M
W
min.
Dielectric Withstand Voltage:
1500 V AC
Daughter Board Insertion Force:
16 oz max. per contact pair
when tested with a .071” thick
gage.
Daughter Board Withdrawal Force:
1 oz min. per contact pair
when tested with a .054” thick
gage.
Operating Temperature:
-54
B
C to +125
B
C
R
C
NO. OF CONTACTS
R
A
Recognized under the recognized component
Program of Underwriters Laboratories, Inc.
File Numbers: E146967 and E176234
POS. / CONTACTS
06/12
10/20
12/24
16/32
18/36
20/40
22/44
25/50
28/56
30/60
36/72
38/76
40/80
43/86
50/100
51/102
56/112
60/120
A
1.011 [25.68]
1.511 [38.38]
1.761 [44.73]
2.261 [57.43]
2.511 [63.78]
2.761 [70.13]
3.011 [76.48]
3.386 [86.00]
3.761 [95.53]
4.011 [101.88]
4.761 [120.93]
5.011 [127.28]
5.261 [133.63]
5.626 [143.15]
6.511 [165.38]
6.636 [168.55]
7.261 [184.43]
7.761 [197.13]
B
0.875 [22.23]
1.375 [34.93]
1.625 [41.28]
2.125 [53.98]
2.375 [60.33]
2.625 [66.68]
2.875 [73.03]
3.250 [82.55]
3.625 [92.08]
3.875 [98.43]
4.625 [117.48]
4.875 [123.83]
5.125 [130.18]
5.500 [139.70]
6.375 [161.93]
6.500 [165.10]
7.125 [180.98]
7.625 [193.68]
C
0.625 [15.88]
1.125 [28.58]
1.375 [34.93]
1.875 [47.63]
2.125 [53.98]
2.375 [60.33]
2.625 [66.68]
3.000 [76.20]
3.375 [85.73]
3.625 [92.08]
4.375 [111.13]
4.625 [117.48]
4.875 [123.83]
5.250 [133.35]
6.125 [155.58]
6.250 [158.75]
6.875 [174.63]
7.375 [187.33]
Dimensions are in inch [mm]
For reference only, can go 1 through 60 positions.
MOUNTING STYLE
.250
[6.35]
.180
[4.57]
.610
[15.49]
.250
[6.35]
1
= Clearance Hole
2
= #4-40 Threaded Insert
3
= Flush Mount
4
= #4-40 Threaded Insert
5
= No Mounting Ear
6
= Side Mounting
WWW.ECSCONN.COM
Please advise on the loading problem of SDIO WIFI!
Hello everyone, we are now using the driver of the MARVELL8686 WIFI chip, but it always fails to load successfully. The printed information is as follows: Can experts help me analyze it? 1 SDBusDriver...
atom1212 Embedded System
11 examples to teach you how to deal with servo motor jitter problems
1. What is the reason why the servo motor cannot start and makes loud noise and vibration? Answer: 1. Disconnect the load. 2. Turn it by hand to confirm that it is flexible and has no abnormalities. 3...
华科星电气 Integrated technical exchanges
TS25L16BP-SCF
-JLS1300-0101 Detailed description: JLSsmall series Lever Push Switches (small type) Features1. One unit of this switch is sufficient for both function selection and entry of the selected function.2. ...
xinyisz PCB Design
vxWorks6.6
Who has the learning materials about vxWorks6.6? I am still learning about vxWorks. I hope my friends can help me. If you have the materials, please send me some. I need them from the most basic opera...
Qiye_87 Real-time operating system RTOS
How does the c2000 Digital Power Library switch current and voltage loops?
How does the c2000 Digital Power Library switch current and voltage loops?...
wsxiaoping3 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1097  2561  71  473  2521  23  52  2  10  51 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号