EEWORLDEEWORLDEEWORLD

Part Number

Search

LK2320-7PD2TB2

Description
AC-DC Regulated Power Supply Module, 2 Output, 150W, Hybrid, METAL, CASE K02, MODULE
CategoryPower/power management    The power supply circuit   
File Size1MB,26 Pages
ManufacturerBel Power Solutions
Download Datasheet Parametric View All

LK2320-7PD2TB2 Overview

AC-DC Regulated Power Supply Module, 2 Output, 150W, Hybrid, METAL, CASE K02, MODULE

LK2320-7PD2TB2 Parametric

Parameter NameAttribute value
Brand NamePower-One
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
Objectid1511184200
Parts packaging codeMODULE
package instruction,
Manufacturer packaging codeCASE K02
Reach Compliance Codecompliant
ECCN codeEAR99
YTEOL0
Other features12V ADDITIONAL OUTPUT AVAILABLE
Analog Integrated Circuits - Other TypesAC-DC REGULATED POWER SUPPLY MODULE
Maximum input voltage264 V
Minimum input voltage85 V
Nominal input voltage310 V
JESD-30 codeR-MXMA-X
JESD-609 codee0
Number of functions1
Output times2
Maximum operating temperature71 °C
Minimum operating temperature-25 °C
Maximum output voltage12.07 V
Minimum output voltage11.93 V
Nominal output voltage12 V
Package body materialMETAL
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Certification statusNot Qualified
surface mountNO
technologyHYBRID
Temperature levelCOMMERCIAL EXTENDED
Terminal surfaceTIN LEAD
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Maximum total power output150 W
Fine-tuning/adjustable outputYES
Cassette Style
AC-DC Converters
K Series
150 Watt AC-DC (DC-DC) Converters
for 400 Hz Mains
Input voltage range from 85...255 V AC
1 or 2 isolated outputs up to 48 V DC
4 kV AC I/O electric strength test voltage
• Input frequency range 47...440 Hz
• No PFC
Extremely wide input voltage range
Input over- and undervoltage lock-out
Efficient input filter and built-in surge and transient
suppression circuitry
Fully isolated outputs
Outputs overload, open- and short-circuit proof
No derating over entire operating temperature range
Safety according to IEC/EN 60950
LGA
K Series
111
4.4"
3U
80
3.2"
16 TE
168
6.6"
Summary
The K series of AC-DC (DC-DC) converters represents a
flexible range of power supplies for use in advanced elec-
tronic systems. Features include wide input frequency
range (no PFC), high efficiency, high reliability, low output
voltage noise and excellent dynamic response to load/line
changes.
The converter inputs are protected against surges and tran-
sients occuring at the source lines. An input over- and
undervoltage lock-out circuitry disables the outputs if the
input voltage is outside the specified range. Certain types
include an inrush current limitation preventing circuit break-
ers and fuses from being damaged at switch-on.
All outputs are open- and short-circuit proof and are pro-
tected against overvoltages by means of a built-in suppres-
sor diode. The outputs can be inhibited by a logic signal ap-
plied to the connector pin 18 (i). If the inhibit function is not
used pin 18 must be connected to pin 14 to enable the out-
puts.
LED indicators display the status of the converter and allow
visual monitoring of the system at any time.
Full input to output, input to case, output to case and output
to output isolation is provided. The modules are designed
and built according to the international safety standards
IEC/EN 60950 and have been approved by the safety
agencies LGA (Germany) und UL (USA). The UL Mark for
Canada has been officially recognized by regulatory au-
thorities in provinces across Canada.
The case design allows operation at nominal load up to
71°C in a free air ambient temperature. If forced cooling is
provided, the ambient temperature may exceed 71°C but
the case temperature must remain below 95°C under all
conditions.
A temperature sensor generates an inhibit signal which
disables the outputs if the case temperature
T
C
exceeds the
limit. The outputs are automatically re-enabled when the
temperature drops below the limit.
Various options are available to adapt the converters to in-
dividual applications.
The modules may either be plugged into 19" rack systems
according to DIN 41494, or be chassis mounted.
Important:
For applications with requirements for com-
pliance with IEC/EN 61000-3-2 (harmonic distortion)
please use our LK 4000 and LK 5000 series.
Table of Contents
Page
Page
Electromagnetic Compatibility (EMC) ............................ 13
Immunity to Environmental Conditions ........................... 15
Mechanical Data ............................................................ 16
Safety and Installation Instructions ................................ 17
Description of Options .................................................... 20
Accessories .................................................................... 26
Summary .......................................................................... 1
Type Survey and Key Data .............................................. 2
Type Key .......................................................................... 2
Functional Description ...................................................... 3
Electrical Input Data ......................................................... 4
Electrical Output Data ...................................................... 5
Auxiliary Functions ......................................................... 10
Edition 5/5.2000
1/26
[RVB2601 Creative Application Development] Environmental Monitoring Terminal 04- Sound Collection and Dynamic Light Bar Display
This article introduces how to use the microphone on the RVB2601 development board to collect surrounding sounds and record the maximum value per unit time to indicate the ambient noise level. For a m...
sipower XuanTie RISC-V Activity Zone
Please tell me, how many output channels does the transformer in the linear adjustable power supply have and how many V does each have?
For example, how should a linear adjustable power transformer with a maximum output voltage of 30V distribute the output voltage, such as 6V, 8V, 12V, 24V, 36V or more outputs? What should be based on...
littleshrimp Power technology
Time Delay Problem of Programmable Gain Amplifier
I would like to ask you to help me with two questions: 1. Does the programmable gain amplifier have time delay? 2. Does the time delay change linearly under different gains? I have searched a lot of i...
wrx_vigos Analog electronics
ARM/Linux/WinCE Lecture
On July 21, the event was held at Shanghai Urban Management Institute, with 200 participants. Three topics: The latest ARM technology and embedded technology development trends (lectured by ARM China ...
szxgl Linux and Android
The confusion of new scholars
I have some idea about embedded systems. I don't know what is the effective learning order. There are so many books and it's hard to choose. Thank you...
gjfzb Embedded System
TI C2000 32-bit Piccolo F2805x MCU simplifies motor control design
[p=21, null, left][color=rgb(102, 102, 102)][font=宋体][size=14px]The new Piccolo F2805x microcontrollers pack many analog components compactly on-chip to improve system efficiency and reduce the number...
fish001 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2844  705  1857  845  1464  58  15  38  18  30 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号