85/86 - 5/8 ” Square Single-Turn Panel Control with Rotary Switch
Potentiometer Specifications
Initial Electrical Characteristics
1
Conductive Plastic Element
Cermet Element
Standard Resistance Range
Linear Tapers (A, B, E, & H) ..................................................................(B & E) 1 K ohms to 1 megohm ............. (A & H) 100 ohms to 1 megohm
Audio Tapers (C, D, F, G, S, & T) .........................................................(D, G, S, & T) 1 K ohms to 1 megohm ... (C & F) 1 K ohms to 1 megohm
Total Resistance Tolerance .........................................................................±20 % or 10 % ...................................... ±10 % or 5 %
Absolute Minimum Resistance ...................................................................2 ohms maximum .................................. 2 ohms maximum
Operating Temperature Range ...................................................................-40 °C to +125 °C.................................. -40 °C to +125 °C
Storage Temperature Range ......................................................................-55 °C to +125 °C.................................. -55 °C to +125 °C
Temperature Coefficient Over Storage Temperature Range ......................±1,000 ppm/°C ...................................... ±150 ppm/°C
Vibration (Single Section) ...........................................................................15 G ....................................................... 15 G
Total Resistance Shift ...........................................................................±2 % maximum ..................................... ±2 % maximum
Voltage Ratio Shift ................................................................................±5 % maximum ..................................... ±5 % maximum
Shock (Single Section) ...............................................................................30 G ....................................................... 30 G
Total Resistance Shift ...........................................................................±2 % maximum ..................................... ±2 % maximum
Voltage Ratio Shift ................................................................................±5 % maximum ..................................... ±5 % maximum
Total Resistance Shift ...........................................................................±10 % maximum ................................... ±5 % maximum
Rotational Life (No Load) ............................................................................100,000 cycles ...................................... 100,000 cycles
Total Resistance Shift ...........................................................................(Linear taper) 10 ohms or ..................... (All tapers) ±5 % TRS maximum
Moisture Resistance (MIL-STD-202, Method 103, Condition B)
Total Resistance Shift ...........................................................................(B & E tapers) ±10 % maximum ........... ±5 % maximum (all tapers)
IP Rating .....................................................................................................IP 40 ...................................................... IP 40
Starting and Running Torque (Non-Locking Bushings)
Single Section ................................................................................................................................................................. 0.14 to 1.06 N-cm (0.2 to 1.5 oz.-in.)
Dual Section .................................................................................................................................................................... 0.14 to 1.06 N-cm (0.2 to 1.5 oz.-in.)
Triple Section ................................................................................................................................................................... 0.35 to 1.41 N-cm (0.5 to 2.0 oz.-in.)
Quadruple Section .......................................................................................................................................................... 0.35 to 1.41 N-cm (0.5 to 2.0 oz.-in.)
Starting and Running Torque (Locking Bushings) ..................................................................................................... 0.14 to 2.82 N-cm (0.2 to 4.0 oz.-in.)
Shaft Locking Torque with Locknut @ 10 in-lb. (B & E Bushings) ........................................................................................................ 14 N-cm (20 oz-in.)
Mounting ...................................................................................................................................................................1.7-2.0 N-m (15-18 lb.-in.) maximum
Weight (Single Section).............................................................................................................................................................................. 21 grams maximum
(Each Additional Section) ...................................................................................................................................................................... 6 grams maximum
Terminals .......................................................................................................................................................................... Printed circuit terminals or J-Hooks
Soldering Condition .................................................................. Recommended hand soldering using Sn95/Ag5 no clean solder, 0.025 ” wire diameter.
Maximum temperature 399 °C (750 °F) for 3 seconds. No wash process to be used with no clean flux.
Marking.......................................................................... Manufacturer’s trademark, wiring diagram, date code and resistance, manufacturer’s part number
Ganging (multiple section potentiometers) ..................................................................................................................................................... 4 cup maximum
Hardware ...........................................One lockwasher and one mounting nut is shipped with each potentiometer, except where noted in the part number.
For dimensional drawings see pages 3 & 4.
For ordering information see page 5.
NOTE: Model 81/82 performance specifications do not apply to units subjected to printed circuit board cleaning procedures.
1At room ambient: +25 °C nominal and 50 % relative humidity nominal, except as noted.
*RoHS Directive 2002/95/EC Jan 27, 2003 including Annex.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications
81/82 - 5/8 ” Square Single-Turn Panel Control
85/86 - 5/8 ” Square Single-Turn Panel Control with Rotary Switch
Rotary Switch Specifications
Initial Electrical Characteristics
1
Contacts:
DPST ...............................................................................................................................................................................N.O/N.O.,N.C./N.C. or N.O./N.C.
DPDT ................................................................................................................................................................................2 N.O./N.C. (break before make)
Power Rating (Resistive Load):
DPST ............................................................................................................ 2 A @ 125 volts RMS-60 Hz or 2 A @ 28 VDC, 1 A @ 250 volts RMS-60 Hz
DPDT ........................................................................................................................................................... 1 A @ 125 volts RMS-60 Hz or 1 A @ 28 VDC
Operating Temperature Range ...........................................................................................................................................................................0 °C to +70 °C
Storage Temperature Range ........................................................................................................................................................................ -65 °C to +125 °C
Vibration (Dual Section) ....................................................................................................................................................................................................... 8 G
(Triple Section) .................................................................................................................................................................................................... 5 G
(Quadruple Section) ........................................................................................................................................................................................... 3 G
Contact Resistance ........................................................................................................................................................................ 10 milliohms maximum
Contact Bounce ......................................................................................................................................................................... 0.1 millisecond maximum
Shock (Dual Section) ......................................................................................................................................................................................................... 20 G
(Triple Section) ...................................................................................................................................................................................................... 15 G
(Quadruple Section) ............................................................................................................................................................................................. 10 G
Contact Resistance ........................................................................................................................................................................ 10 milliohms maximum
Contact Bounce ......................................................................................................................................................................... 0.1 millisecond maximum
Rotational Life ..................................................................................................................................................................................................... 25,000 cycles
Switch Actuating Torque (50% Duty cycle @ Rated Power Load) .................................................................................. 1.41 to 4.94 N-cm (2 to 7 oz.-in.)
Contact Resistance ...................................................................................................................................................................... 100 milliohms maximum
Moisture Resistance (MIL-STD-202, Method 106, Condition B)
Contact Resistance (0.1 VDC-10 mA) ............................................................................................................................................ 10 milliohms maximum
Switch Housing Material ................................................................................................................. High temperature, flame retardant, thermosetting plastic
Mechanical Characteristics
1
Actuating Torque (Each Section, Switch Module Only) ....................................................................................................... 3.53 to 10.6 N-cm (5 to 15 oz.-in.)
Running Torque (Out of Detent, 2-4 Module Assembly)..................................................................................................... 0.21 to 1.41 N-cm (0.3 to 2 oz.-in.)
Detent ..................................................................................................................................................................................................... CW or CCW standard
Contact Materials ..........................................................................................................................................................................Fine silver with gold overlay
Terminal Styles .................................................................................................................................................................................................. Solder lug only
Standard Orientation ..............................................................................................................................................................In-line with control terminals
Optional .......................................................................................................................................................................... Rotated 90 ° CCW from standard
Terminal Strength (Before and After Soldering Heat Exposure) .......................................................................................................... 0.9 Kg (2 lbs.) minimum
NOTE: Model 81/82 performance specifications do not apply to units subjected to printed circuit board cleaning procedures.
1At room ambient: +25 °C nominal and 50 % relative humidity nominal, except as noted.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications
Today, when debugging STM32F103RCT6, I found a problem. The previous library program did not run at all. When using the latest 3.10, I found that the program always stopped at while((RCC->CR & RCC_CR_...
The definition of strtoul is: unsigned long strtoul(const char *str, char **endptr, int requestedbase, int *ret) It can be seen that ADS1.2 will point the NULL pointer to address 0, but address 0 is w...
I have used OPEN AT to complete the GPRS activation part, but why can't I receive anything in the data stream? I can receive PPP packets by using ATD*99***1# in the hyperterminal. How can I use OPEN A...
In the MCS-51 microcontroller, a 12Mhz clock is used, and timer T0 uses mode 1 (16-bit counter). In the following program, what is the output frequency of p1.0? MOV TMOD,#01H SETB TR0 LOOP:MOV TH0,#0B...
[i=s]This post was last edited by dontium on 2015-1-23 12:46[/i]A relay is an electrical control device. It has an interactive relationship between the control system (also known as the input circuit)...
With the booming electronics industry, vision systems have become a leader in the electronics automation sector. However, the delicate nature of electronic products often affects product yields due...[Details]
Most of the houses we live in now are elevator buildings, mainly because it is more convenient to go up and down the stairs! It can also make life more comfortable. It even helps to increase the ad...[Details]
On August 24th, media outlets reported, citing sources, that NavInfo, a listed company on the A-share market, is nearing completion in its acquisition of the intelligent driving c...[Details]
Long ago, the lifespan of cars in my country was 15 years. Once a car reached 15 years old, it was forced to be scrapped. However, the policy was later changed. As long as the car does not exceed 6...[Details]
Zos Automotive Research Institute released the "2025
Smart Cockpit
Tier 1 Research Report (Domestic Edition)."
This report analyzes the operating conditions of more than a dozen ...[Details]
On August 22, according to the Ministry of Industry and Information Technology's official website, my country's first mandatory national standard for the control of hazardous substances in electric...[Details]
Electric vehicles are now widespread, but they've brought with them a host of problems, the most prominent of which is charging. Small electric vehicles (EVs) are a new form of transportation in a ...[Details]
Tires are a very important component for cars. They are related to the driving experience of the vehicle. We are almost inseparable from cars in our daily lives. For tires, according to the role of...[Details]
My career has been closely tied to the semiconductor industry. From product management to content marketing, I've provided countless forecasts and predictions across a variety of roles. Whethe...[Details]
In the field of intelligent driving, regulations are becoming increasingly stringent, and the technical threshold continues to rise. Especially after the traffic accident in March 2025, the Ministr...[Details]
With the increasing popularity of automated equipment, linear modules, a common auxiliary device for automated equipment, have also seen a bright future. In particular, in recent years, many small ...[Details]
In daily life, when we purchase a transformer, we are faced with the installation and wiring procedures. Generally speaking, large transformers such as power transformers are equipped with speciali...[Details]
There are many motors that can use thyristor speed control, and they can be used in almost all industries. Various types of motors, such as fans, pumps, AC motors, DC motors, torque motors, single-...[Details]
Civilian internal combustion engines operate in the range of approximately 1000-4000 rpm. This results in the engine's kinetic energy being ineffective at low or high rpm, making starting difficult...[Details]
From time to time, I see some audiophiles spending a lot of money or a lot of time to DIY speakers, but the results are not what they want. Below I list some of the small experiences I summarized b...[Details]