EEWORLDEEWORLDEEWORLD

Part Number

Search

BU-63925F2-421W

Description
Mil-Std-1553 Controller, CMOS
CategoryThe embedded processor and controller    Microcontrollers and processors   
File Size983KB,48 Pages
ManufacturerData Device Corporation
Download Datasheet Parametric View All

BU-63925F2-421W Overview

Mil-Std-1553 Controller, CMOS

BU-63925F2-421W Parametric

Parameter NameAttribute value
Objectid1334450677
Reach Compliance Codecompliant
technologyCMOS
uPs/uCs/peripheral integrated circuit typeSERIAL IO/COMMUNICATION CONTROLLER, MIL-STD-1553
BU-63825
SPACE LEVEL MIL-STD-1553
BC/RT/MT
ADVANCED COMMUNICATION ENGINE
(SP’ACE II) TERMINAL
FEATURES
Make sure the next
Card you purchase
has...
®
®
Direct Replacement for BU-61582
and BU-61583
Radiation Tolerant & Radiation
Hardened Versions
Fully Integrated 1553 Terminal
Flexible Processor Interface
16K x 16 Internal RAM
Automatic BC Retries
Programmable BC Gap Times
BC Frame Auto-Repeat
Intelligent RT Data Buffering
Ceramic Package
DESCRIPTION
The BU-63825(925) is a fully hardware & software compatible, direct
drop-in replacement for the BU-61582(83).
DDC’s BU-63825(925) Space Advanced Communication Engine
(Sp’ACE II) is a radiation hardened version of the BU-61580(81) ACE
terminal. DDC supplies the BU-63825 with enhanced screening for
space and other high reliability applications.
The BU-63825 provides a complete integrated BC/RT/MT interface
between a host processor and a MIL-STD-1553 bus. The
BU-63825(925) provides functional and software compatibility with
the standard BU-61580(81) product and is packaged in the same 1.9
square-inch package footprint.
As an option, DDC can supply the BU-63825 with space level screen-
ing. This entails enhancements in the areas of element evaluation
and screening procedures for active and passive elements, as well as
the manufacturing and screening processes used in producing the
terminals.
The BU-63825 integrates dual transceiver, protocol, memory man-
agement and processor interface logic, and 16K words of RAM in the
choice of 70-pin DIP or flat pack packages. Transceiverless versions
may be used with an external electrical or fiber optic transceiver.
To minimize board space and ‘glue’ logic, the Sp’ACE II terminals
provide flexibility in interfacing to a host processor and internal/exter-
nal RAM.
Multiple Ordering Options;
+5V (Only)
+5V/-15V
+5V/-12V
+5V/Transceiverless
+5V (Only, with Transmit Inhibits)
WARNING: EXPORT CONTROLLED PRODUCT
This data sheet or product brief consists of Data De-
vice Corporation general product information that does
not contain controlled technical data as defined in the
International in Arms Regulations (ITAR) Part 120.10 or
Export Administration Regulations (EAR) Part 734.7-11.
The technology described herein is controlled under the
EAR and may not be exported without proper authoriza-
tion by the U.S. Department of Commerce as determined
on a case by case basis.
FOR MORE INFORMATION CONTACT:
Data Device Corporation
105 Wilbur Place
Bohemia, New York 11716
631-567-5600 Fax: 631-567-7358
www.ddc-web.com
Technical Support:
1-800-DDC-5757 ext. 7677 or 7381
7771
All trademarks are the property of their respective owners.
© 2005 Data Device Corporation
f28035 HRCAP I configured as follows, why can't I enter the interrupt?
I have read the datasheet of HRCAP of f28035 and the routine hrcap_capture_hrpwm of TI, and initialized my program according to the configuration in the routine. However, when I add the falling edge, ...
506977544 Microcontroller MCU
Painful wince memory problem, who can help me think of a solution
When I was developing with net cf, I found that after Show or ShowDialog a form, if I close or Dispose to close the window, if I open and close it again, the memory will keep decreasing and will not b...
aihys Embedded System
Master's thesis - Stewart using fuzzy neural network compensator
Stewart using fuzzy neural network compensator...
lorant RF/Wirelessly
How to connect ESP8266 to OneNet cloud platform as a safety black box for engineers
[i=s]This post was last edited by sipower on 2020-5-28 23:05[/i]The previous posts shared my preparations and system block diagrams. This time I will share something that has little to do with sensors...
sipower ST MEMS Sensor Creative Design Competition
Application of Modbus TCP to Profinet Gateway in Water Treatment System
1. There are two Siemens S7-1200PLCs and a DCS system on site. The DCS system acts as a Modbus TCP master station and provides Modbus TCP protocol type data, while the two S7-300 PLCs on site use the ...
bjnytx Integrated technical exchanges
Questions about 51 chips
Why can the MCS-51 external program memory and data memory have the same address without data conflict?...
hailong201 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 596  2682  1206  2484  1274  12  54  25  51  26 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号