C1560XABBR-B

Description
switch rocker dpdt 16a 250v
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size72KB,4 Pages
ManufacturerARCOL
Environmental Compliance  
Download Datasheet View All

C1560XABBR-B Online Shopping

Suppliers Part Number Price MOQ In stock  
C1560XABBR-B - - View Buy Now

C1560XABBR-B Overview

switch rocker dpdt 16a 250v

Technical Information - Switches and Fuseholders
Most major technical information is shown on each specific product page, other details are grouped here
for easy reference. Details shown here apply to most switches and fuseholders. Safety switches (page 56),
indicators (pages 66-80) and connectors (pages 81-83) have product specific information within the
section.
technical
data
MATERIALS
MOST PRODUCTS
EXCEPTIONS
Body and actuator (opaque) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Nylon 6.6 . . . . . . . . . . . . . . . .8300V, 1900V, 0916V & 0911V bezels & actuators
are stainless steel
0600 and 3900 actuators are plated brass
Actuator (transparent) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Polycarbonate
Current carrying parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Copper Alloy
Contact points . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Silver Alloy . . . . . . . . . . . . . . .N/A for 0055/56, 0600/2, 0916-0920, 0017,
2000 & 3005/3006. Gold plated for 1100.
PROPERTIES
Electrical
Class II compliant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Confirmed . . . . . . . . . . . . . . . .IEC Sockets
Electrical life (Operations) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .>10k, many >50k . . . . . . . . .See relevant page for details
Mechanical life (Operation) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .See relevant page for details
Contact resistance (switches) new condition . . . . . . . . . . . . . . . . . . . . . .<100mΩ (at 12Vdc,1A) . . . . .For 1100 & 2000 call sales
Contact resistance (fuseholders) new condition . . . . . . . . . . . . . . . . . . .5mΩ (average)
Insulation resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .>20MΩ
Dielectric strength:
across open contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .>1.5kV
between poles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .>1.5kV
between live parts and accessible metal . . . . . . . . . . . . . . . . . . . . .>3kV
Comparative Tracking Index (CTI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .>250
Temperature rise (terminals) at end of rated life . . . . . . . . . . . . . . . . . . .max 30˚K (UL 1054), max 55˚K (EN 61058-1)
PROPERTIES
Physical
Humidity resistance at 91-95% relative humidity
(to subsequently comply with requirements of the
Dielectric strength test) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48hrs
Impact resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .>0.5Nm
Storage temp. (1 year period) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .<125˚C . . . . . . . . . . . . . . . . .Some discoloration of terminals may occur
Flame retardancy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .UL94V2
Solderability to BS 2011 pt.2.1T - (with an iron) . . . . . . . . . . . . . . . . . . .6 secs at 350°C
Angular movement ±4° overall (where applicable) . . . . . . . . . . . . . . . . .38° . . . . . . . . . . . . . . . . . . . .1250, 6000, 8500, 8550, 8600, 8650, 8800 - 26°
Force to operate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.0N - 20.0N . . . . . . . . . . . . .Call sales for specific values
INGRESS PROTECTION
IP40 unless otherwise stated.
Higher ratings where available will be shown on the relevant catalogue page.
4
Phone: 760-343-3650 •
Arcolectric
• Email: americas@elektron-technology.com
How to power the device when the USB of LM3S9B96 is used as a non-OTG host?
When used as a non-OTG host, is the slave device powered by USB0VBUS? I read in the data sheet that when used as a non-OTG host device, USB0VBUS and USB0ID can be released for use as GPIO. Isn't VBUS ...
ultrabenz Microcontroller MCU
Urgent: About f2812 clock problem
I just built a board and found that the 2812 output clock is 2.5MHz after powering on. The crystal is 20MHz (20pF). I don't know why?...
zhazhyrjkf3 Microcontroller MCU
To all moderators
Good morning, all moderators! After several weeks of joint efforts, the forum has improved significantly. On behalf of the Electronic Engineering World Network, I would like to thank you all! I hope t...
sw Suggestions & Announcements
LED Reliability Test Standards- Comprehensive Information
LED reliability test standards - comprehensive information The attachment is the LED reliability test standards, including the test standards for direct-plug LEDs, surface-mount LEDs and high-power LE...
探路者 Power technology
LED dot matrix screen program
Can anyone help me change the program to 32X80? Now it displays 16x16 flowing from left to right. I want to change it to 32x32. Thank you....
duwanli MCU
EEWORLD University ---- Machine Learning Techniques
Machine Learning Techniques : https://training.eeworld.com.cn/course/4458...
老白菜 DIY/Open Source Hardware

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 775  707  285  1362  1694  16  15  6  28  35 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号