EEWORLDEEWORLDEEWORLD

Part Number

Search

CPK600PS30

Description
AC-DC chassis mount
File Size826KB,4 Pages
ManufacturerXP Power
Websitehttps://www.xppower.com/
Download Datasheet Compare View All

CPK600PS30 Overview

AC-DC chassis mount

AC-DC Chassis Mount
600-1000 Watts
CPK Series
T
HE
XP
ERTS
I
N
P
OWER
Up to 2 kW Peak Rating
Wide Output Voltage Adjustment
Up to 500 W Convection Cooled
Optional Conformal Coating
Optional Remote ON/OFF
Optional AC, DC & Fan Fail Signals
Specification
Input
Input Voltage
Input Frequency
Inrush Current
Power Factor
Earth Leakage Current •
85-264 VAC (120-350 VDC)
47-63 Hz
20/40 A typical at 115/230 VAC
0.98 typical at 230 VAC at 100% load
0.75 mA max at 230 VAC 60Hz
for 0.50 mA add suffix ‘-E’,
for 0.15 mA add suffix ‘-G’
Switching
Frequency
Vertical
Terminal block
Din Rail Mounting
Fan Fitted
N+1 Operation
Alarms (Optional)
Conformal Coating
85 kHz ±15% active PFC
130 kHz ±15% forward converter
Add suffix ‘-T’ to model numbers
Add suffix ‘-NI’ to model numbers
Add suffix ‘-F’ to model number
(only available on 24 V units)
Option ‘-W’ & external oring diodes
For AC fail, DC fail and fan fail add
suffix ‘-W’ to model number
Add suffix ‘-L’ to model numbers
Output
Output Voltage
Output Voltage
Adjustment
Minimum Load
Start Up time
Hold Up time
Initial Set Accuracy
Drift
Line Regulation
Load Regulation
Ripple & Noise
Overvoltage
Protection
Overcurrent
Protection
Remote ON/OFF
(Optional)
See Table
See Table
No minimum load required
500 ms max at 100 VAC 100% load
20 ms typical at 100 VAC 100% load
±1% max
±0.4%
±0.4% from low line to high line
±0.7% max from 0-100% load
±0.8% max pk-pk 20 MHz bandwidth
115-140% of Vnom, recycle input to
restart
101% of peak current auto recovery
Add suffix ‘-R’ to model number
ON 4.5-12.5 V (open circuit)
between RC+ and RC-
OFF 0 to 0.5 V (short circuit)
between RC+ and RC-
Environmental
Operating
Temperature
-10 °C to +70 °C (fan cooled)
Derate linearly above +50 °C to 60%
load at +70 °C.
For convection cooled rating - See
Derating Curves
-20 °C to +75 °C
20-90% RH non-condensing
20 G, 11 ms once each, X, Y & Z axis
2 G, 3 min period, 60 min each along
X, Y & Z axis
Storage Temperature
Relative Humidity
Shock
Vibration
EMC & Safety
Emissions
EN55022 level B conducted
(level A with option E not available with
option G) EN55022 level B radiated
EN61000-4-2 Level 2 contact Level 3 air
EN61000-4-3 Level 3
EN61000-4-4 Level 4
EN61000-4-5 Level 3 line to line
Level 4 line to ground
UL60950, C-UL (CSA60950),
EN60950, EN50178
General
Efficiency
Isolation
86-89% dependent on model
3000 VAC Input to Output
2000 VAC Input to Ground
ESD Susceptibility
Radiated
Susceptibility
EFT/Burst
Surge
Safety Approvals
www.xpplc.com
sales@xpplc.com

CPK600PS30 Related Products

CPK600PS30 CPK600PS24 CPK600PS36 CPK600PS48
Description AC-DC chassis mount AC-DC chassis mount AC-DC chassis mount AC-DC chassis mount

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2333  2161  1853  1983  2093  47  44  38  40  43 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号