The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
3.96 mm Pitch Miniature Connectors for Internal Power Supplies (UL,C-UL and TÜV Listed)
DF7 Series
Complete
Locking
Function
Completely
enclosed
locking system
Full barrier
between adjacent
contacts.
Prevention of
Incorrect Connections
s
Features
1. Complete Locking Function
Reliable interior lock protects mated connectors from
accidental disconnection.
2. Increased Contact Retention of Crimped
Contacts and Prevention of Incomplete
Insertion
Separate contact retainer increases the contact
retention, assures and visually confirms the complete
contact insertion.
3. Molded-in Contact Retention Tabs
Handling of terminated contacts during the assembly and
termination is easier and avoids entangling of wires,
since there are no protruding metal tabs.
4. Incorrect Insertion Prevention
Connectors are polarized to assure correct mating with
corresponding parts.
Guide post
5.Solder Crack Prevention
Glass reinforced resin is used in the pin header bodies to
prevent solder cracks caused by the heat shrinkage.
Board Eyelet mounting
6. Prevention of Incorrect Board Placement
Built-in locating posts assure correct connector
placement and orientation on the board.(2-12 pos.)
7. Supports Sealing after Installation.
Sealing compound can be applied to the board installed
connector for distance of 6 mm max. from the mounting
surface (9 mm max. for single position).
8.Cost Effective Tooling
The same crimping tools are used to terminate socket
and pin contacts.
9. Prevention of Short Circuits between
Adjacent Contacts
Each contact is completely surrounded by the insulator
housing, electrically isolating it from adjacent contacts.
One pos. type can also be mounted
to boards that have eyelets.
Continued.
B95
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
10. 10 A maximum Current
Connector can carry current of 10 A per contact with
#16 AWG conductor.Refer to page 3 for current
ratings for multi-position connectors using other
conductor sizes.
12. Supports Eyelets
1 pos. can be mounted to boards which have eyelets
attached.
11. Color Variations
1 pos. is available in a standard 3 colors: natural,
blue, and red.
s
Applications
Office equipment, power supplies for industrial, medical
and instrumentation applications, variety of consumer
electronic and electrical applications.
Crimp Sockets
qSingle
row
qDouble
rows
Retainer
(optional, order separately)
Shown with terminated
and installed contacts.
Refer to page 8 for details.
Shown with terminated
and installed contacts.
Refer to page 11 for details.
Header
qSingle
row, straight type
qDouble
rows, straight type
In-line plug
qPanel
lock type
Refer to page 10 for details.
Refer to page 4 for details. Refer to page 10 for details.
qSingle
row, right angle type
qDouble
row, right angle type
Shown with
terminated and installed contacts.
Refer to page 6 for details.
Refer to page 5 for details. Refer to page 10 for details.
Shown with
terminated and installed contacts.
Refer to page 7 for details.
sOrdering
information
qSocket,
Header
DF7 -
*
S - 3.96 C
1
2
3
4
5
1
Series name: DF7, DF7A
2
Number of contacts: 1 to 12
3
Connector type
S: Socket
DS: Double-row socket
P: Header
DP: Double-row Header
EP: In-line plug
RS/P: Retainer
6
Applicable Conductor
1618: AWG 16 to AWG 18
2022: AWG 20 to AWG 22
2426: AWG 24 to AWG 26
7
Packaging
SCF: Socket contacts / Reel
SC: Socket contacts / Bag
PCF: Plug contacts / Reel
PC: Plug contacts / Bag
qContacts
DF7 -
**
SCF
1
6
7
4
Contact pitch: 3.96mm(7.92 mm)
5
Type of housing: header
C: Crimp housing
DSA: Straight header
DS: Right-angle header
Blank: Retainer
B96
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
sProduct
Specifications
Row
1
Current
rating
2
Ratings
No. of contacts
1~10
4
6
8
10
12
AWG16
10A
10A
9A
9A
8A
8A
AWG18
7A
9A
8A
8A
7A
7A
AWG20
5A
7A
6A
6A
5A
5A
AWG22
4A
6A
5A
5A
4A
4A
Operating temperature range -35ç to 85ç (Note 1)
Operating humidity range
20% to 80%
Storage temperature range
Storage humidity range
UL/C-UL/TÜV
UL
C-UL
TÜV
-10çto 60ç (Note 2)
40% to 70% (Note 2)
Specificatoin
Voltage
rating
AC 630V
AC 600V
AC 600V(7.92mm pitch)
AC 300V (3.96mm pitch)
File No.and Recognition No
:E52653
:E52653
:R9750437
UL/C-UL
TÜV
Item
11.
Contact resistance
12.
Insulator resistance
13.
Withstanding voltage
14.
Insertion-Extraction force
(per contact)
15.
Durability
(mating/unmating)
16.
Vibration
17.
Shock
18.
Humidity
Specification
Contact resistance(Initial value)
1000 M ohms min.
No flashover or Insulator breakdown
0.3N min., 4.5N max.
30 cycles
No momentary disconnections of 1 µs min.
No electrical discontinuity of 1 µs. min.
Contact resistance 20 m ohms max.
Condition
10 m ohms max. 20mV max., 1mA
500 V DC
1500 V AC for 1 minute
Measured with a steel pin of 0.64 x 1.2 ± 0.002 mm
Contact resistance of 20 m ohms max.
Frequency 10 to 55 Hz, single amplitude of 0.75 mm, 3 axis, 2
hours
Acceleration of 490 m/s
2
, 11 ms duration, sine half-wave
waveform, 3 cycles in each of the 3 axis.
Temperature 40ç ± 2ç, 90% to 95% RH, 96 hours
(-55ç: 30 minutes
¡
5 to 35ç: 5 minutes
¡
85ç: 30 minutes
¡
5
to 35ç: 5 minutes) for 5 cycles
Flow solder temperature 250ç, 10 seconds
Manual soldering: Soldering iron temperature 300ç, 3 seconds
19.
Temperature cycle Contact resistance of 20 m ohms max.
10. Resistance to
soldering heat
No deformation of the insulator parts affecting
performance
Note 1: Includes temperature rise caused by the current flow.
Note 2: The term “storage” refers to products stored for long period of time prior to mounting and use. Operating Temperature Range
and Humidity range covers non- conducting condition of installed connectors in storage, shipment or during transportation.
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
s
Straight header
Part Number
DF7- 1P-3.96DSA
DF7- 2P-3.96DSA
DF7- 3P-3.96DSA
DF7- 4P-3.96DSA
DF7- 5P-3.96DSA
DF7- 6P-3.96DSA
DF7- 7P-3.96DSA
DF7- 8P-3.96DSA
1 Pos.
DF7- 9P-3.96DSA
DF7-10P-3.96DSA
DF7- 2P-7.92DSA
DF7- 3P-7.92DSA
DF7- 4P-7.92DSA
DF7- 5P-7.92DSA
CL No.
CL680-0133-1
CL680-0036-5
CL680-0037-8
CL680-0038-0
CL680-0039-3
CL680-0040-2
CL680-0041-5
CL680-0042-8
CL680-0043-0
CL680-0044-3
CL680-0108-4
CL680-0109-7
CL680-0110-6
CL680-0111-9
Number of contacts
1
2
3
4
5
6
7
8
9
10
2
3
4
5
A
-------------
10.40
14.36
18.32
22.28
26.24
30.20
34.16
38.12
42.08
14.36
22.28
30.20
38.12
B
-------------
3.96
7.92
11.88
15.84
19.80
23.76
27.72
31.68
35.64
7.92
15.84
23.76
31.68
2 to 10 Pos.
Note 1) Bag packaging (100 pieces/bag). Order by number of bags.
Note 2) The 2 pos. type does not have walls on both sides.
Note 3) DF7-2P-7.92DSA plug has #2 contact positions of DF7-3P-3.96DSA without contacts inserted and the number of pos. indication is 2.
(Mating receptacle: DF7#-3S-3-96C)
DF7-3P-7.92DSA plug has #2 and #4 contact positions of DF7-5P-3.96DSA without contacts inserted and the number of pos. indication is 3.
(Mating receptacle: DF7#-5S-3-96C)
DF7-4P-7.92DSA plug has #2, #4 and #6 contact of DF7-7P-3.96DSA without contacts inserted and the number of pos. indication is 4.
(Mating receptacle: DF7#-7S-3-96C)
DF7-5P-7.92DSA plug has #2, #4, #6 and #8 contact positions of DF7-9P-3.96DSA without contacts inserted and the number of pos. indication is 5.
(Mating receptacle: DF7#-9S-3-96C)
1 Pos.
7.8
6.44
4.55
1
2 to 10 Pos.
No. of contacts
indicator (Note3)
P=3.96
4.55
A
B
7.1
9.9
2.8
(Note2)
(Note1)
12.2
12.9
9E26
3.5
3.2
Production Lot No.
0.64
0.84
3.5
7
M0.64
Cavity No.
A
Cavity No.
DF7
2.49
Ø1.4
6
Production Lot No.
B
PCB mounting pattern (Board thickness: 1.6
±
0.1)
1 Pos.
Ø3.9
MAX
Eyelet
Board
2 to 10 Pos.
Ø5
MAX
Soldering side
Ø1
.
6
+0
0 .1
1.7
3.45
5.5
Note 5: One pos. type can also be mounted to boards
that have installed eyelets.
8±0.1
0.8±0.1
3.6±0.1
5.4
_0.3
+0.1
Ø
1.1
.1
+0
0
P=3.96±0.05(7.92±0.05)
Ø1.6
_0.25
for eyelet
1.4
+0.1
mm Without eyelet
_0
+0.15
B±0.1
2.49±0.05
B98
3.45±0.05
6L09
10
B
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
s
Right angle header
P=3.96
7.7
A
2.8
(Note1)
7
18
6L09
M0.64
3.5
1.1
1.4
C
7.8
10
Production Lot No.
A
1.1
Cavity No.
No. of contacts indicator (Note2)
B
9.5
2.2
10
A
Ø1.4
Part Number
DF7- 2P-3.96DS(24)
DF7- 3P-3.96DS(24)
DF7- 4P-3.96DS(24)
DF7- 5P-3.96DS(24)
DF7- 6P-3.96DS(24)
DF7- 7P-3.96DS(24)
DF7- 8P-3.96DS(24)
DF7- 9P-3.96DS(24)
DF7-10P-3.96DS(24)
DF7- 2P-7.92DS(24)
DF7- 3P-7.92DS(24)
DF7- 4P-7.92DS(24)
DF7- 5P-7.92DS(24)
CL No.
CL680-0081-0-24
CL680-0082-2-24
CL680-0083-5-24
CL680-0084-8-24
CL680-0085-0-24
CL680-0086-3-24
CL680-0087-6-24
CL680-0088-9-24
CL680-0089-1-24
CL680-0124-0-24
CL680-0125-3-24
CL680-0126-6-24
CL680-0127-9-24
Number of contacts
2
3
4
5
6
7
8
9
10
2
3
4
5
A
3.96
7.92
11.88
15.84
19.80
23.76
27.72
31.68
35.64
7.92
15.84
23.76
31.68
B
10.40
14.36
18.32
22.28
26.24
30.20
34.16
38.12
42.08
14.36
22.28
30.20
38.12
C
8.40
12.36
16.32
20.28
24.24
28.20
32.16
36.12
40.08
12.36
20.28
28.20
36.12
Quantity per tray
114
84
66
60
48
42
36
36
30
84
60
42
36
Note 1) Tray packaging. Order by number of quantity in the tray.
Note 2) DF7-2P-7.92DS plug has #2 contact positions of DF7-3P-3.96DS without contacts inserted and the number of pos. indication is 2.
(Mating receptacle: DF7#-3S-3-96C)
DF7-3P-7.92DS plug has #2 and #4 contact positions of DF7-5P-3.96DS without contacts inserted and the number of pos. indication is 3.
(Mating receptacle: DF7#-5S-3-96C)
DF7-4P-7.92DS plug has #2, #4 and #6 contact of DF7-7P-3.96DS without contacts inserted and the number of pos. indication is 4.
(Mating receptacle: DF7#-7S-3-96C)
DF7-5P-7.92DS plug has #2, #4, #6 and #8 contact positions of DF7-9P-3.96DS without contacts inserted and the number of pos. indication is 5.
I recently used 28335 to communicate with the host computer. The host computer inquired about the working status of 28335. 28335 needs to reply 20 bytes of data each time. 288335 only sends 16 bytes i...
I am using a z8 cpu with 1k ram and 8k rom. In the boot program, I have used code to copy the data in rom to ram, as shown below: IF COPYPRAM LD R0,#high(_low_pramseg) LD R1,#low(_low_pramseg) LD R2,#...
First: Information display electronic instruments, equipment, household appliances, information display, digital display and various displays, as well as LED display screens (information display, adve...
[color=red][font=宋体][size=10.5pt][color=#000000][align=left]Moderator's note: The original content of this post was written based on the old version of djyos. The process of setting up the environment...
Why can't the external interrupt be enabled in low power mode 0 of msp430g2553? I need some help. It doesn't work in low power mode 1 or 2, but only in mode 3 or 4. The code is as follows: #includevoi...
PV DC fuses are safety devices used to protect PV panels, inverters, and DC loads. To ensure their safety and reliability, they must be UL248 certified.
Before applying for UL248 certifi...[Details]
Electric vehicles are currently gaining momentum, but this is just a facade. Fuel-powered vehicles remain unchallenged. While electric vehicles boast unique advantages in environmental emissions an...[Details]
As the number of cars increases, environmental pressures are also increasing. At this time, some people are saying that new energy vehicles are energy-efficient and environmentally friendly, and ar...[Details]
With the rapid advancement of automation technology, collaboration between robots is no longer just science fiction. Imagine dozens of machines moving goods in a warehouse without interfering with ...[Details]
Keysight Technologies is combining its electromagnetic simulator with Synopsys' AI-driven RF design migration flow to create an integrated design flow for migrating from TSMC's N6RF+ process techno...[Details]
Coal mines typically contain gas and coal dust. When gas and coal dust reach a certain concentration, they can cause explosions. Electrical equipment generates arcs during normal operation or durin...[Details]
Plessey Semiconductors has been acquired by Haylo Labs, which was established in March last year with a $100 million, five-year loan from Chinese technology company Goertek.
Haylo Labs w...[Details]
In daily life, power transformers have different functions and uses due to different usage scenarios. The most common ones can be divided into: control transformers, isolation transformers, rectifi...[Details]
A patent disclosed by Ford proposes replacing traditional segmented side curtain airbags with integrated full-width side curtain airbags that span the side of the vehicle and can be deployed simult...[Details]
Bosch has released a new SoC series to support L2+ advanced driver assistance functions. The chip integrates high resolution and long-range detection capabilities, and has built-in support for neur...[Details]
Introduction: In digital circuit calculations, there is no concept of decimal points. You know where the decimal is, but the circuit does not know where the decimal point is. Therefore, you need to...[Details]
In this final installment of a five-part blog series, I will discuss noise in op amps driving headphone loads and some techniques for reducing it. Previous posts have discussed headphone load power...[Details]
The intelligent
dust monitoring system intelligently monitors dust concentrations at and around construction sites. All concentration values are transmitted to a cloud server for
cloud co...[Details]
The primary control objective in this case is the display and alarming of data parameters on the Xinheng control scale instrument. The system's main PLC uses a Siemens CPU, and data is collected vi...[Details]
In recent years, with the development of MOSFETs, they have gradually replaced transistors in the low-power, fast-switching industry. Major manufacturers in this field have also been reducing their...[Details]