EEWORLDEEWORLDEEWORLD

Part Number

Search

312300102

Description
Thumb/Pushwheel Switch, 1 Switches, BCD Complement, 10 Positions, 0.1A, 28VDC, Solder Terminal, Panel Mount, ROHS COMPLIANT
CategoryMechanical and electronic products    switch   
File Size668KB,8 Pages
ManufacturerITT
Websitehttp://www.ittcannon.com/
Environmental Compliance
Download Datasheet Parametric View All

312300102 Overview

Thumb/Pushwheel Switch, 1 Switches, BCD Complement, 10 Positions, 0.1A, 28VDC, Solder Terminal, Panel Mount, ROHS COMPLIANT

312300102 Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
body width18.52 mm
body height33.02 mm
Body length or diameter28.96 mm
Contact (AC) maximum rated R load.1A@120VAC
Maximum contact current (AC)0.1 A
Maximum contact current (DC)0.1 A
Contact (DC) maximum rated R load.1A@28VDC
Maximum contact voltage (AC)120 V
Maximum contact voltage (DC)28 V
Electrical life100000 Cycle(s)
Installation featuresPANEL MOUNT
Number of positions10
Number of switching segments1
Maximum operating temperature65 °C
Minimum operating temperature-10 °C
sealDUST PROOF
surface mountNO
switch functionBCD COMPLEMENT
Switch typeTHUMB/PUSHWHEEL SWITCH
Termination typeSOLDER
Base Number Matches1
C&K 3 Series
Thumbwheel Switches
Features/Benefits
Most complete product offering in the industry
Spacers available to fit most panel cutouts
Front or rear mounting options
Typical Applications
Test & measurement equipment
Industrial equipment
Computer devices
Specifications
CONTACT RATING:
CARRY: 1 AMP continuous.
SWITCH: 100 mA max.
OPERATING VOLTAGE: 50 mV to 28 V DC or 120 V AC.
ELECTRICAL LIFE: 100,000 actuations.
CONTACT RESISTANCE: Below 100 m
typ. initial @
2-4 V DC, 100 mA.
INSULATION RESISTANCE: 109
min.
DIELECTRIC STRENGTH: 500 Vrms min. @ sea level
between common terminal and any output.
OPERATING TEMPERATURE: -10ºC to 65ºC.
Materials
HOUSING: ABS plastic.
THUMBWHEEL: ABS plastic.
ROTOR CONTACTS: Precious metal on copper alloy.
STATOR CONTACTS: Hard gold over nickel over copper
on epoxy fiberglass.
NOTE:
Specifications and materials listed above are for switches with standard options
For information on specific and custom switches, consult Customer Service Center.
* Note: All models listed are RoHS compliant. See Technical Data section of this catalog for
RoHS compliant and compatible definitions and specifications.
Build-A-Switch
To order, simply select desired option from each category and place in the appropriate box. Available options are shown and
described on pages N–9 thru N–12. For additional options not shown in catalog, consult Customer Service Center.
Consult factory for illumination availability.
Thumbwheel & Pushwheel
Series
3
Thumbwheel switch
Number of Sections
0
Switch section
1
1 Switch section
2
2 Switch sections
3
3 Switch sections
4
4 Switch sections
5
5 Switch sections
6
6 Switch sections
7
7 Switch sections
8
8 Switch sections
9
More than 8
switch sections
Function Code
11
Decimal, SP, 10 position
14
Resistor decade
21
BCD, 10 position
23
Complement of BCD, 10 position
27
BCD, 10 position
31
BCD, 10 position
71
BCH, 16 position
Mounting Style
00
Snap-in, front mount
09
Snap-in, front mount*
10
Rear mount
Terminations
19
Rear mount*
0
Type 0
20
Rear mount
1
Type 1, extended type 0
29
Rear mount*
N
Solder pins with .100” spacing**
P
Solder pins with .156” spacing**
9
Any combination
Color/Marking/Stops
0
Matte black body, gloss
black wheel,
white marking
N
*X9 mounting styles must be ordered with ‘0’ number of sections.
** Note: Termination option N (RoHS compliant) replaced termination option 3 (Non-RoHS compliant).
Termination option P (RoHS compliant) replaced termination option B (Non-RoHS compliant).
Seal
0
No seal
1
Sealed contacts
2
Dust lens
3
Sealed contacts & dust lens
Dimensions are shown: Inch (mm)
Specifications and dimensions subject to change
N–8
www.ittcannon.com
How to divide the clock and use it as the input clock for another module?
I want to use the divided clock as the input clock of the UARTAutomatic module. How can I connect the following two modules together? [/font][/backcolor][/color] [color=#222222][backcolor=rgb(238, 238...
xiazq FPGA/CPLD
How to improve the frequency accuracy of the resonant circuit?
Hello everyone, we want to develop an accessory, which uses the same circuit as the washing machine water level sensor. When the core insertion position changes, the coil inductance changes, the reson...
konfig Analog electronics
Analysis of WDM Kernel Driver Model
Analysis of WDM kernel driver model WDM driver is an important part of Windows 2000 operating system. Its normal operation requires the support of other kernel components of Windows 2000. At the same ...
fengchui Embedded System
I recently made an alarm clock using MSP430FR2633, so here comes the question!
I recently made an alarm clock using MSP430FR2633, so here comes the problem! CapTIvate touch, modify ui8TouchThreshold by yourself. I didn’t use any GUI tool to modify the touch threshold, but I chan...
蓝雨夜 Microcontroller MCU
【Book Collection】100 Latest Examples of Multimeter Uses
This book is the sequel to the book "Wonderful Use of Multimeters", which specifically introduces the latest application technology of multimeters. The book is divided into three parts. Chapter 1 summ...
wzt Test/Measurement
Amplifier Module
[i=s] This post was last edited by paulhyde on 2014-9-15 09:17 [/i] :) I am preparing the amplifier now, but I don’t know how to start with the filter. Should I also make some modules in advance? ? ? ...
木瓜 Electronics Design Contest

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2312  2025  2303  473  1808  47  41  10  37  2 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号