Description
Three Phase EMI Filter,
CategoryAnalog mixed-signal IC    filter   
File Size611KB,5 Pages
ManufacturerSchaffner
Environmental Compliance
Download Datasheet Parametric View All

FN3472-315-99-E2XXXRX Overview

Three Phase EMI Filter,

FN3472-315-99-E2XXXRX Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid145230730950
Reach Compliance Codeunknown
DATASHEET
Ecosine max (5% THDi) FN 3472
Ecosine max, 400 VAC 60 Hz Full Performance Passive Harmonic Filters
Demonstrate best cost-performance ratio
Achieve 5% THDi for diode rectifier without
DC-link choke and thyristor rectifier
Best-in-class partial load performance
Most compact open panel design for cabinet
integration
Reliable and robust
Plug and play, ready to use
Approvals & Compliances
Features and benefits
Schaffner ecosine harmonic filters represent an
economical solution to the challenge of load-applied
harmonics mitigation in three-phase power systems.
With a plug-and-play approach and more compact
dimensions than comparable products, they can be
quickly installed and easily commissioned. They
increase the reliability and service life of electric
installations, help utilize electric sytem capacity
better, and are the key to meet Power Quality
standards such as IEEE 519. Ecosine filters reshape
your distorted current back to the desired sinusoidal
waveform. Schaffner ecosine filters can be applied to
virtually any kind of power electronics with front-end
six-pulse rectifiers, 3-phase diode or thyristor bridges,
where harmonic current distortion needs to be
reduced to defined limits.
Technical specifications
Nominal operating voltage
Operating frequency
Nominal motor drive input power rating
Total harmonic current distortion THDi*
Efficiency
Overload capability
SCCR**
High potential test voltage
Overvoltage category
Earthing System
Protection category
Cooling
Ambient temperature range
3 x 380 VAC to 415 VAC ±10%
60 Hz ±1 Hz
280 to 480HP
<5% @ rated power for drives without Ldc
~3.5% @ rated power for drives equipped with 4% Ldc
>99% for rated voltage and power
1.6x rated current for 1 minute, once per hour
100 kA (UL approved)
P -> E 2520 VAC (1s)
OV III (IEC 60664-1)
TN, TT, IT
IP 00
External cooling***
–25°C to +40°C fully operational
+40°C to +70°C derated operation****
–25°C to +85°C transport and storage
Filter: UL 61800-5-1, EN 61800-5-1
Chokes: EN 60076-6
UL 94 V-2
>200,000 hours
Typical applications
Equipment with front-end six-pulse rectifier
Motor drives
Factory automation equipment
Water/wastewater treatment facilities
Fan and pump applications
HVAC installations
Mission-critical processes
DC fast chargers
Design corresponding to
Flammability corresponding to
MTBF @ 40°C/400 V (Mil-HB-217F)
Typical electrical schematic
*****System requirements: THDv <2%, line voltage unbalance <1%
*****Note:
performance specifications in this brochure refer to six-pulse diode rectifiers.
*****SCR
rectifier front-ends will produce different results, dependent upon the firing angle of the thyristors.
*****External UL-rated fuses required. Please consult the user manual.
*****Please check the inlet air flow required for cooling table further in this document and the user manual.
*****I
derated
= I
nominal
*√((T
max-
T
amb
)/(T
max-
T
nominal
)) = I
nom
*√((70°C-T
amb
)/30°C)
Is this the transportation of the future?
[i=s]This post was last edited by qwqwqw2088 on 2016-5-14 22:11[/i] [align=left]Toyota has developed an intelligent three-wheeled electric vehicle, the i-Road. From the outside, the i-Road is small an...
qwqwqw2088 Talking
Summary of commonly used shortcut keys in Protel99
Summary of commonly used shortcut keys in Protel99...
不是归人是过客 Analog electronics
What is the difference between RTL Viewer and Technology Map Viewer?
Could you please tell me the difference between RTL Viewer and Technology Map Viewer?...
eeleader FPGA/CPLD
Special Topic of 2005 China International Communication Equipment and Technology Exhibition
[i=s]This post was last edited by jameswangsynnex on 2015-3-3 20:00[/i] The largest information and communication exhibition in Asia,sponsored by the Ministry of Information Industry of the People's R...
newlooking Mobile and portable
The problem of Linux system controlling two GPRS modems for TCP/IP communication
I have two GPRS modems. I can send AT commands to dial into GPRS through the serial port, which is equivalent to establishing two connections. When I connect to the server as a client, how can I contr...
wende Linux and Android
Apply for a free trial! Fluke Norma6000 Power Analyzer, born for convenience!
How to ensure safety during on-site power electronic power supply testing?How to accurately test complex electrical signals, harmonics and efficiency?What to do if the desktop instrument is inconvenie...
EEWORLD社区 Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2749  2801  347  343  1064  56  57  7  22  58 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号