EEWORLDEEWORLDEEWORLD

Part Number

Search

1.0MHZCFPT-9060CY4C

Description
TCVCXO, CLOCK, 1 MHz, ACMOS OUTPUT, ROHS COMPLIANT, SMD, 6 PIN
CategoryPassive components    oscillator   
File Size473KB,3 Pages
ManufacturerIQD Frequency Products
Environmental Compliance
Download Datasheet Parametric View All

1.0MHZCFPT-9060CY4C Overview

TCVCXO, CLOCK, 1 MHz, ACMOS OUTPUT, ROHS COMPLIANT, SMD, 6 PIN

1.0MHZCFPT-9060CY4C Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompli
Other featuresTRI-STATE; ENABLE/DISABLE FUNCTION; TAPE AND REEL; BULK
Ageing1 PPM/FIRST YEAR
Maximum control voltage4.2 V
Minimum control voltage
maximum descent time3 ns
Frequency Adjustment - MechanicalNO
Frequency offset/pull rate50 ppm
frequency stability1.5%
Installation featuresSURFACE MOUNT
Nominal operating frequency1 MHz
Maximum operating temperature105 °C
Minimum operating temperature-55 °C
Oscillator typeACMOS
Output load15 pF
physical size14.7mm x 9.2mm x 6.2mm
longest rise time3 ns
Maximum supply voltage3.63 V
Minimum supply voltage2.97 V
Nominal supply voltage3.3 V
surface mountYES
maximum symmetry45/55 %
Base Number Matches1
CFPT-9050 SMD TCVCXO
iSSUE 8; 1 NOVEMBER 2008 - RoHS 2002/95/EC
Supply Current
Description
0.3ppm TCXO manufactured for us by Rakon utilising their
Pluto™ ASIC technology. Its wide frequency range, operating
temperature range and drive capability coupled with high
stability and linear frequency pulling make it the ideal
reference oscillator. Its ability to function down to a supply
voltage of 2.4V and low power consumption makes it suitable
for mobile applications
14.7 x 9.2mm
9.6, 10, 12.8, 19.44, 20, 38.88, 49.152, 51.84MHz
HCMOS 15pF max
ACMOS 50pF max
Sinewave 10k
W
// 10pF, AC-coupled
Clipped sinewave 10k
W
// 10pF, AC-coupled
Temperature: see table
Typical Supply Voltage Variation ± 10% < ± 0.2 ppm*
Typical Load Coefficient 15pF ± 5pF < ± 0.2 ppm*
*Depending on frequency and output type
HCMOS Typically:
1+ Frequency(MHz)*Supply(V)*{Load(pF)+ 15}*10
–3
mA
eg. 20MHz, 5V, 15pF ≈ 4mA
ACMOS Typically:
1+ Frequency(MHz)*Supply(V)*{Load(pF)+ 23}*10
–3
mA
Sinewave, 6 to 12 mA depending on frequency
Clipped Sinewave, Typically:
1+ Frequency(MHz)*1.2*{Load(pF)+ 30}*10
–3
mA
± 1ppm maximum in first year
± 3ppm maximum for 10 years
± 1ppm maximum after reflow
Optional reference voltage output on Pad 5, suitable for
potentiometer supply or DAC reference.
1. No output (Standard option)
2. 2.2V, for Min. Vs > 2.4V
3. 2.7V, for Min. Vs > 3.0V
4. 4.2V, for Min. Vs > 4.5V
Maximum load current (mA) = Vref/10
Package Outline
Ageing
Standard Frequencies
Output Compatibility & Load
Reference Voltage, Vref (HCMOS/ACMOS only)
Frequency Stability
Frequency Adjustment
Three options with external Voltage Control applied to Pad 1:
For manual frequency adjustment (HCMOS/ACMOS output
only) connect an external 50kW potentiometer between Pad 5
(Reference Voltage) and Pad 3 (GND) with wiper connected to
Pad 1 (Voltage Control). Please specify reference voltage as a
part of the ordering code.
TCXOs
A - Ageing adjustment: > ± 5ppm (Standard Option)
B - No frequency adjustment. Initial calibration @ 25°C
< ± 0.5 ppm
C - High Pulling ±10ppm to ±50ppm may be available
depending on specification options. Contact our sales office
Linearity <1% (positive slope)
Input resistance >100k
W
Modulation bandwidth >2kHz
Standard control voltage ranges:
Without reference voltage - Vs = 5.0V 2.5V ± 2V
Without reference voltage - Vs = 3.3V 1.65V ± 1V
With reference voltage - Vc = 0V to Vref
–55 to 125°C
Logic ‘1’ (>60%Vs) to Pad 2 enables output
Logic ‘0’ (<20%Vs) to Pad 2 disables output
When at logic ‘0’ the output stage is disabled for all output
options, but the oscillator and compensation circuit are still
active (Current consumption < 1mA)
Standard 3.3V, 5.0V (see table)
Supply voltages in the range 2.4 to 6.0V available to order,
please contact our sales office
Note: Please contact our sales office if a reference voltage is
required in combination with sine or clipped sinewave output
Environmental
Vibration: IEC 60068-2-6 Test Fc Procedure B4, 10-60Hz
1.5mm displacement, 60 –2000Hz at 98.1 ms
–2
, 30 minutes
in each of three mutually perpendicular planes at 1 octave
per minute
Shock: IEC 60068-2-27 Test Ea, 980ms
–2
acceleration for
6ms duration, 3 shocks in each direction along three mutually
perpendicular planes
Solderabiltiy: MIL-STD-202, Method 208, Category 3
Factory Code + Part Number (E and four digits) + Frequency
(MHz) + Pad 1 / Static sensitivity identifier (Triangle) + Date
code
Bulk or Tape & Reel
Frequency + Model Number + Frequency Stability vs
Operating Temperature Range Code + Reference Voltage
Code + Frequency Adjustment Code
Marking includes
Storage Temperature Range
Tri-State Operation
Packaging
Minimum Order information Required
Supply Voltage
IQD Frequency Products Ltd, Station Road, Crewkerne, Somerset TA18 8AR, United Kingdom
Tel: +44 (1460) 270200; Fax: +44 (1460) 72578;
Email: info@iqdfrequencyproducts.com Web: www.iqdfrequencyproducts.com
Recommended one: [Lingsheng] MCU code automatic generator (automatic programming tool)
Recommended one: [Lingsheng] MCU code automatic generator (automatic programming tool)In the past, programming MCU programs depended entirely on programmers typing codes, which was difficult to learn ...
net2uizoo Creative Market
Learning 3D visualization scene hierarchy from scratch (1)
1. Enable scene level control 2. Parent-child tree and classification object attribute tree 3. Switch scene level After loading the park in the 3D visualization scene, the system will automatically cr...
森友js Sensor
CC1200 receives data packets and reads RXBYTES which is often 0
When CC1200 receives data packets, the synchronization word can be received, but when reading the number of received bytes RXBYTES, it is often 0, resulting in packet loss. Which registers need to be ...
huamao1987 RF/Wirelessly
Problems when running the enet_uip routine of 9B96
When running the enet_uip routine of 9B96, when using static IP, the IP address is displayed on the screen. However, when the IP address is entered on the web page, it cannot be displayed. . . Can som...
wzp2007 Microcontroller MCU
【Nucleo-F413ZH】Development Board Review_Serial Port Usage
Serial port debugging of the microcontroller is very convenient. Of course, this is also one of the commonly used debugging methods. Let's take a look at the serial port related to Nucleo-F413ZH: [ali...
一厢情愿 stm32/stm8
Download ON Semiconductor KNX technical documents and win wonderful gifts!
[size=5][color=#ff0000]Event Details >> [url=https://www.eeworld.com.cn/huodong/201507_ONSemi/index.php] Download ON Semiconductor KNX technical documents and win exquisite gifts! [/url][/color][/size...
EEWORLD社区 Integrated technical exchanges

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1660  550  1901  1416  969  34  12  39  29  20 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号