E
Approved
Ericsson Internal
TABLE OF SPECIFICATION
PRODUCT CONTENTS
No.
2 (3)
1 (4)
Prepared (also subject responsible if other)
EAB/FAC/P Susanne Eriksson
SEC/S Gavin Du
BMR 463
[Susanne Eriksson]
EAB/FAC/P
series
POL Regulators
Key Features
Checked
BPOW 00201-00152 Uen
1/1301-BMR 463
Technical
Uen
Date
Rev
Input
4.5-14
V, Output up to
25
A /
82.5
W
•
Small package
25.65 x 13.8 x 8.2 mm (1.01 x 0.543 x 0.323 in)
SIP: 26.3 x 7.6 x 15.6 mm (1.035 x 0.30 x 0.614 in)
•
0.6 V - 3.3 V output voltage range
•
High efficiency, typ. 97.1% at 5Vin, 3.3Vout half load
•
Configuration and Monitoring via PMBus
•
Adaptive compensation of PWM control loop & fast loop
transient response
•
Synchonization & phase spreading
•
Current sharing, Voltage Tracking & Voltage margining
•
MTBF 20.2 Mh
2009-07-10
2014-01-03
EN/LZT 146 434
R4B
February
2014
© Ericsson AB
Reference
Specification
D
F
D
X
General Characteristics
For narrow board pitch applications (15 mm/0.6 in)
Non-Linear Response for reduction of decoupling cap.
Input under voltage shutdown
Over temperature protection
Output short-circuit &
Output over voltage
protection
Remote Control & Power Good
Voltage setting via pin-strap or PMBus
Advanced Configurable via Graphical
Used Interface
•
ISO 9001/14001 certified supplier
•
Highly automated manufacturing ensures quality
•
•
•
•
•
•
•
•
Safety Approvals
Design for Environment
Meets requirements in high-
temperature lead-free soldering
processes.
Contents
Ordering Information
General Information
Safety Specification
Absolute Maximum Ratings
Preliminary Electrical Specification
20A/ 0.6-3.3V Through hole and Surface mount version
20A/ 0.6-3.3V Single in Line version (SIP)
25A/ 0.6-3.3V Through hole and Surface mount version
25A/ 0.6-3.3V Single in Line version (SIP)
............................................................. 2
............................................................. 2
............................................................. 3
............................................................. 4
BMR4630002, BMR4631002
BMR4630006, BMR4631006 ................ 5
BMR4632002...................................... 14
BMR4630008, BMR4631008
BMR4630009, BMR4631009 .............. 23
BMR4632008...................................... 32
EMC Specification
Operating Information
Thermal Consideration
Connections
Mechanical Information
Soldering Information
Delivery Information
Product Qualification Specification
........................................................... 41
........................................................... 41
........................................................... 52
........................................................... 53
........................................................... 63
........................................................... 66
........................................................... 67
........................................................... 69
E
SEC/S Gavin Du
Approved
Ericsson Internal
PRODUCT SPECIFICATION
No.
2 (4)
Prepared (also subject responsible if other)
BMR 463 series
POL Regulators
Input
4.5-14
V, Output up to
25
A /
82.5
W
Ordering Information
Product program
BMR 463 x002/001 (x=0,1,2)
BMR 463 2102/001
BMR 463 x006/001 (x=0,1)
BMR 463 x008/001 (x=0,1,2)
BMR 463 x009/001 (x=0,1)
Output
0.6-3.3 V, 20 A/ 66 W
0.6-3.3 V, 20 A/ 66 W
0.6-3.3 V, 20 A/ 66 W
0.6-3.3 V, 25 A/ 82.5 W
0.6-3.3 V, 25 A/ 82.5 W
Checked
1/1301-BMR 463
Technical
Uen
Date
Rev
2014-01-03
EN/LZT 146 434
R4B
February
2014
© Ericsson AB
Reference
Specification
2
F
X
Mean steady-state failure rate,
λ
49 nFailures/h
Std. deviation,
σ
12.4 nFailures/h
MTBF (mean value) for the BMR 463 series = 20.2 Mh.
MTBF at 90% confidence level = 15.3 Mh
Compatibility with RoHS requirements
The products are compatible with the relevant clauses and
requirements of the RoHS directive 2002/95/EC and have a
maximum concentration value of 0.1% by weight in
homogeneous materials for lead, mercury, hexavalent
chromium, PBB and PBDE and of 0.01% by weight in
homogeneous materials for cadmium.
Exemptions in the RoHS directive utilized in Ericsson
Power Modules products are found in the Statement of
Compliance document.
ο
Ericsson Power Modules fulfills and will continuously fulfill
all its obligations under regulation (EC) No 1907/2006
concerning the registration, evaluation, authorization and
restriction of chemicals (REACH) as they enter into force
and is through product materials declarations preparing for
the obligations to communicate information on substances
in the products.
Quality Statement
The products are designed and manufactured in an
industrial environment where quality systems and methods
like ISO 9000, Six Sigma, and SPC are intensively in use to
boost the continuous improvements strategy. Infant
mortality or early failures in the products are screened out
and they are subjected to an ATE-based final test.
Conservative design rules, design reviews and product
qualifications, plus the high competence of an engaged
work force, contribute to the high quality of our products.
Warranty
Warranty period and conditions are defined in Ericsson
Power Modules General Terms and Conditions of Sale.
Limitation of Liability
Ericsson Power Modules does not make any other
warranties, expressed or implied including any warranty of
merchantability or fitness for a particular purpose
(including, but not limited to, use in life support
applications, where malfunctions of product can cause
injury to a person’s health or life).
© Ericsson AB 2014
The information and specifications in this technical
specification is believed to be correct at the time of
publication. However, no liability is accepted for
inaccuracies, printing errors or for any consequences
thereof. Ericsson AB reserves the right to change the
contents of this technical specification at any time without
prior notice.
Product number and Packaging
BMR 463 n
1
n
2
n
3
n
4
/n
5
n
6
n
7
n
8
Options
n
1
n
2
n
3
n
4
/
n
5
Mounting
/
ο
Mechanical
Hardware
Variants
Configuration
Packaging
Options
n
1
Description
0
1
2
0
1
02
06
08
09
n
6
n
7
n
8
ο
ο
ο
/
/
/
/
ο
ο
ο
Through hole mount version (TH)
Surface mount version (SMD)
Single in line (SIP)
Standard mechanical option
5.5mm pin length (for SIP)
20 A, Pin 4A = Voltage Tracking pin
20 A, Pin 4A = Power Good pin
25 A, Pin 4A = Voltage Tracking pin,
Dynamic Loop Compensation
25 A, Pin 4A = Power Good pin,
Dynamic Loop Compensation
CTRL pin positive logic (active high)
CTRL pin negative logic (active low)
Antistatic tray of 100 products (SIP only)
Antistatic tape & reel of 200 products
(Sample delivery available in lower
quantities. Not for SIP)
n
2
n
3
n
4
n
5
n
6
n
7
n
8
001
002
B
C
Example: Product number BMR 463 0002/001C equals a through-hole
mounted, standard mechanical option, voltage tracking pin at 4A, positive
RC logic, package tape&reel.
General Information
Reliability
The failure rate (
λ
) and mean time between failures
(MTBF= 1/
λ
) is calculated at max output power and an
operating ambient temperature (T
A
) of +40°C. Ericsson
Power Modules uses Telcordia SR-332 Issue 2 Method 1
to calculate the mean steady-state failure rate and
standard deviation (
σ
).
Telcordia SR-332 Issue 2 also provides techniques to
estimate the upper confidence levels of failure rates based
on the mean and standard deviation.
E
SEC/S Gavin Du
Approved
Ericsson Internal
PRODUCT SPECIFICATION
No.
3 (4)
Prepared (also subject responsible if other)
BMR 463 series
POL Regulators
Input
4.5-14
V, Output up to
25
A /
82.5
W
Safety Specification
General information
Ericsson Power Modules DC/DC converters and DC/DC
regulators are designed in accordance with safety
standards IEC/EN/UL 60950-1
Safety of Information
Technology Equipment.
IEC/EN/UL 60950-1 contains requirements to prevent injury
or damage due to the following hazards:
•
•
•
•
•
•
Electrical shock
Energy hazards
Fire
Mechanical and heat hazards
Radiation hazards
Chemical hazards
Checked
1/1301-BMR 463
Technical
Uen
Date
Rev
2014-01-03
EN/LZT 146 434
R4B
February
2014
© Ericsson AB
Reference
Specification
3
F
X
Isolated DC/DC converters
It is recommended that a slow blow fuse is to be used at
the input of each DC/DC converter. If an input filter is used
in the circuit the fuse should be placed in front of the input
filter.
In the rare event of a component problem that imposes a
short circuit on the input source, this fuse will provide the
following functions:
•
•
Isolate the fault from the input power source so as
not to affect the operation of other parts of the
system.
Protect the distribution wiring from excessive
current and power loss thus preventing hazardous
overheating.
On-board DC/DC converters and DC/DC regulators are
defined as component power supplies. As components
they cannot fully comply with the provisions of any safety
requirements without “Conditions of Acceptability”.
Clearance between conductors and between conductive
parts of the component power supply and conductors on
the board in the final product must meet the applicable
safety requirements. Certain conditions of acceptability
apply for component power supplies with limited stand-off
(see Mechanical Information for further information). It is
the responsibility of the installer to ensure that the final
product housing these components complies with the
requirements of all applicable safety standards and
regulations for the final product.
Component power supplies for general use should comply
with the requirements in IEC 60950-1, EN 60950-1 and
UL 60950-1
Safety of Information Technology Equipment.
There are other more product related standards, e.g.
IEEE 802.3
CSMA/CD (Ethernet) Access Method,
and
ETS-300132-2
Power supply interface at the input to
telecommunications equipment, operated by direct current
(dc),
but all of these standards are based on
IEC/EN/UL 60950-1 with regards to safety.
Ericsson Power Modules DC/DC converters and DC/DC
regulators are UL 60950-1 recognized and certified in
accordance with EN 60950-1.
The flammability rating for all construction parts of the
products meet requirements for V-0 class material
according to IEC 60695-11-10,
Fire hazard testing, test
flames
– 50 W horizontal and vertical flame test methods.
The products should be installed in the end-use equipment,
in accordance with the requirements of the ultimate
application. Normally the output of the DC/DC converter is
considered as SELV (Safety Extra Low Voltage) and the
input source must be isolated by minimum Double or
Reinforced Insulation from the primary circuit (AC mains) in
accordance with IEC/EN/UL 60950-1.
The galvanic isolation is verified in an electric strength test.
The test voltage (V
iso
) between input and output is
1500 Vdc or 2250 Vdc (refer to product specification).
24 V DC systems
The input voltage to the DC/DC converter is SELV (Safety
Extra Low Voltage) and the output remains SELV under
normal and abnormal operating conditions.
48 and 60 V DC systems
If the input voltage to the DC/DC converter is 75 Vdc or
less, then the output remains SELV (Safety Extra Low
Voltage) under normal and abnormal operating conditions.
Single fault testing in the input power supply circuit should
be performed with the DC/DC converter connected to
demonstrate that the input voltage does not exceed
75 Vdc.
If the input power source circuit is a DC power system, the
source may be treated as a TNV-2 circuit and testing has
demonstrated compliance with SELV limits in accordance
with IEC/EN/UL60950-1.
Non-isolated DC/DC regulators
The input voltage to the DC/DC regulator is SELV (Safety
Extra Low Voltage) and the output remains SELV under
normal and abnormal operating conditions.
E
Approved
Ericsson Internal
PRODUCT SPECIFICATION
No.
1 (21)
Prepared (also subject responsible if other)
EAB/FJB/GM QLAANDR
BMR 463 series
POL Regulators
EAB/FJB/GM (Ksenia Harrisen)
Checked
2/1301-BMR 463
Technical
Uen
Date
Rev
Input
4.5-14
V, Output up to
25
A /
82.5
W
(MICRF)
2013-11-01
EN/LZT 146 434
R4B
February
2014
© Ericsson AB
Reference
Specification
4
C
Absolute Maximum Ratings
Characteristics
T
P1
T
S
V
I
Operating temperature (see Thermal Consideration section)
Storage temperature
Input voltage (See Operating Information Section for input and output voltage relations)
CTRL, SA0, SA1, SALERT, SCL, SDA, VSET, SYNC, GCB, PG
-S, PREF, GND
V
O
, +S, VTRK
min
-40
-40
-0.3
-0.3
-0.3
-0.3
typ
max
125
125
16
6.5
0.3
6.5
Unit
°C
°C
V
V
V
V
Logic I/O voltage
Ground voltage differential
Analog pin voltage
Stress in excess of Absolute Maximum Ratings may cause permanent damage. Absolute Maximum Ratings, sometimes referred to as no destruction limits, are
normally tested with one parameter at a time exceeding the limits in the Electrical Specification. If exposed to stress above these limits, function and performance
may degrade in an unspecified manner.
Configuration File
This product is designed with a digital control circuit. The control circuit uses a configuration file which determines the functionality and performance of the product.
The Electrical Specification table shows parameter values of functionality and performance with the default configuration file, unless otherwise specified. The default
configuration file is designed to fit most application needs with focus on high efficiency. If different characteristics are required it is possible to change the
configuration file to optimize certain performance characteristics. Note that current sharing operation requires changed configuration file. See application notes
AN307 and AN312 for further information.
In this Technical specification examples are included to show the possibilities with digital control. See Operating Information section for information about tradeoffs
when optimizing certain key performance characteristics.
Fundamental Circuit Diagram
C
i
= 70 μF, C
o
= 200 μF
E
Approved
Ericsson Internal
PRODUCT SPECIFICATION
No.
2 (21)
Prepared (also subject responsible if other)
EAB/FJB/GM QLAANDR
BMR 463 series
POL Regulators
EAB/FJB/GM (Ksenia Harrisen)
Checked
2/1301-BMR 463
Technical
Uen
Date
Rev
Input
4.5-14
V, Output up to
25
A /
82.5
W
(MICRF)
2013-11-01
EN/LZT 146 434
R4B
February
2014
© Ericsson AB
Reference
Specification
5
C
Electrical Specification
BMR 463 0002, BMR 463 1002, BMR 463 0006, BMR 463 1006
T
P1
= -30 to +95 °C, V
I
= 4.5 to 14 V, V
I
> V
O
+ 1.0 V
Typical values given at: T
P1
= +25 °C, V
I
= 12.0 V, max I
O
, unless otherwise specified under Conditions.
Default configuration file, 190 10-CDA 102 0175/001.
External C
IN
= 470 µF/10 mΩ, C
OUT
= 470 µF/10 mΩ. See Operating Information section for selection of capacitor types.
Sense pins are connected to the output pins.
Characteristics
Conditions
min
typ
V
I
Input voltage rise time
Output voltage without pin strap
Output voltage adjustment range
Output voltage adjustment including
margining
Output voltage set-point resolution
Output voltage accuracy
V
O
Internal resistance +S/-S to VOUT/GND
V
O
= 0.6 V
V
O
= 1.0 V
V
O
= 1.8 V
V
O
= 3.3 V
V
O
= 0.6 V
V
O
= 1.0 V
V
O
= 1.8 V
V
O
= 3.3 V
V
O
= 0.6 V
V
O
= 1.0 V
V
O
= 1.8 V
V
O
= 3.3 V
0
V
O
= 0.6 V
V
O
= 1.0 V
V
O
= 1.8 V
V
O
= 3.3 V
22
V
O
= 0.6 V
V
O
= 1.0 V
V
O
= 1.8 V
V
O
= 3.3 V
V
O
= 0.6 V
V
O
= 1.0 V
V
O
= 1.8 V
V
O
= 3.3 V
V
O
= 0.6 V
V
O
= 1.0 V
V
O
= 1.8 V
V
O
= 3.3 V
V
O
= 0.6 V
V
O
= 1.0 V
V
O
= 1.8 V
V
O
= 3.3 V
V
O
= 0.6 V
V
O
= 1.0 V
V
O
= 1.8 V
V
O
= 3.3 V
8
6
5
4
84.0
89.3
92.8
94.8
79.3
86.0
90.7
93.6
3.12
3.25
3.68
4.52
0.56
0.57
0.68
0.99
1.26
1.94
3.31
5.89
monotonic
1.2
0.60
See Note 17
Including line, load, temp.
See Note 14
Current sharing operation
See Note 15
0.54
±0.025
-1
-2
4.7
2
2
2
3
3
2
2
2
20
30
40
60
max
2.4
Unit
V/ms
V
V
V
% V
O
3.3
3.63
1
2
%
%
Ω
Line regulation
mV
Load regulation; I
O
= 0 - 100%
mV
V
Oac
Output ripple & noise
C
O
= 470
μ
F (minimum external
capacitance). See Note 11
mVp-p
I
O
I
S
I
lim
I
sc
Output current
20
A
Static input current at max I
O
Current limit threshold
Short circuit
current
RMS, hiccup mode,
See Note 3
A
30
A
A
50% of max I
O
η
Efficiency
max I
O
%
%
P
d
Power dissipation at max I
O
W
P
li
Input idling
power
(no load)
Default configuration:
Continues Conduction
Mode, CCM
W