EEWORLDEEWORLDEEWORLD

Part Number

Search

170M1362

Description
Electric Fuse, 32A, 700VAC, 200000A (IR), Inline/holder,
CategoryCircuit protection    Circuit protection   
File Size195KB,3 Pages
ManufacturerCooper Industries
Environmental Compliance
Download Datasheet Parametric View All

170M1362 Online Shopping

Suppliers Part Number Price MOQ In stock  
170M1362 - - View Buy Now

170M1362 Overview

Electric Fuse, 32A, 700VAC, 200000A (IR), Inline/holder,

170M1362 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompli
body width21 mm
body height40 mm
Body length or diameter54 mm
Built-in featuresINDICATOR
Circuit protection typeELECTRIC FUSE
Joule integral nominal40 J
Manufacturer's serial number170M
Installation featuresINLINE/HOLDER
method of packingBOX
physical size54mm x 21mm x 40mm
Rated breaking capacity200000 A
Rated current32 A
Rated voltage (AC)700 V
GuidelineCE; CSA; DIN 43653; IEC; UL
surface mountNO
Terminal shapeTAB/BLADE
Base Number Matches1
High Speed Fuses
Square Body DIN 43 653 — 690V/700V (IEC/UL): 10-400A
690V/700V (IEC/UL) 10-400A
Specifications
Description:
Square body DIN
43-653 stud mount high speed
fuses.
Dimensions:
See dimensions
illustration.
Ratings:
Volts: — 690Vac (IEC)
— 700Vac (UL)
Amps: — 10-400A
IR: — 200kA RMS Sym.
Agency Information:
CE,
Designed and tested to IEC
60269: Part 4, UL Recognized.
UL Recognition/CSA Component
Acceptance on Size 000.
Electrical Characteristics
Total Clearing I
2
t
The total clearing I
2
t at
rated voltage and at power
factor of 15% are given
in the electrical
characteristics. For other
voltages, the clearing I
2
t is
found by multiplying by
correction factor, K, given
as a function of applied
working voltage, Eg, (rms).
1.5
K
1.0
Arc Voltage
This curve gives the
peak arc voltage, UL,
which may appear
across the fuse during
its operation as a
function of the applied
working voltage, Eg,
(rms) at a power factor
of 15%.
Power Losses
Watts loss at rated
current is given in the
electrical characteristics.
The curve allows the
calculation of the power
losses at load currents
lower than the rated
current. The correction
factor, Kp, is given as a
function of the RMS
load current, Ib, in % of
the rated current.
1.4
1.2
10
3
9
8
7
6
5
4
3
U
L
E
g
200
300
400
500
600 690
1.0
K
p
0.8
0.6
0.5
0.4
0.3
0.2
High Speed
Fuses
0.1
30 40 50
60
70
I
b
80 90 100%
0.5
0.4
0.3
0.2
Features and Benefits
• Excellent DC performance
• Low arc voltage and low energy let-through (I
2
t)
• Low watts loss
• Superior cycling capability
E
g
100 200 300 400 500 600 690
Dimensions (mm)
Type -U/80, -/80, -TN/80
Siz e
000
00
D
40
51
E
21
30
F
20
28
G
51
67
H
8
10
K
2
2
Typical Applications
DC common bus
DC drives
Power converters/rectifiers
Reduced voltage starters
For Other Voltage Ratings in This Body Style
• See page 144 (1000V)
1mm = 0.0394” / 1” = 25.4mm
54
Indicator
Dimensions (mm)
Type 00B/60, 00BTN/60
*
1mm = 0.0394” / 1” = 25.4mm
M8
D
K
30
6
64
54 Max
G
100
78
48
E
H
F
62
* Indication for Size 00 fuses is a red pin.
Indicator
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa
117

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1432  2919  1905  1434  1484  29  59  39  30  26 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号