EEWORLDEEWORLDEEWORLD

Part Number

Search

8340-F130-K3K2-ALH0-15A

Description
cir brkr mag 15a 240vac 80vdc
CategoryCircuit protection   
File Size455KB,6 Pages
ManufacturerE-T-A [E-T-A Circuit Breakers]
Environmental Compliance  
Download Datasheet View All

8340-F130-K3K2-ALH0-15A Overview

cir brkr mag 15a 240vac 80vdc

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...
Description
Single and multipole magnetic circuit breakers with trip-free mechanism
and toggle actuation. A choice of fast magnetic only or hydraulically
delayed switching characteristics (S-type MO or HM CBE to EN 60934)
ensures suitability for a wide range of applications. Industry standard
dimensions and panel mounting. Options include auxiliary changeover
contacts, or relay trip function. Low temperature sensitivity at rated load.
Approved to CBE standard EN 60934 (IEC 60934).
Typical applications
Control equipment, communications systems, transportation, power
supplies.
1-pole
Standard current ratings and typical internal resistance values
8340-F...
2-pole
Technical data
Current
rating (A)
0.02
0.05
0.1
0.25
0.5
0.75
1
2
2.5
3
5
6
8
10
12
15
16
20
25
30
40
50
Curves and internal resistance per pole (Ω)
F1
F2
K1, M1, T1, K2, M2, T2
1493
276
58
8.2
2.3
0.98
0.58
0.145
0.096
0.065
0.025
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
≤ 0.01
≤ 0.01
953
152
37
6.0
1.47
0.63
0.35
0.096
0.061
0.048
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
-
-
2669
452
100
15.5
3.9
1.65
0.95
0.26
0.15
0.10
0.042
0.029
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
≤ 0.01
≤ 0.01
2457
376
94
14.7
3.2
1.56
0.90
0.20
0.15
0.10
0.040
0.028
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
-
-
For further details please see chapter: Technical Information
Voltage rating
3 AC 415 V; AC 240 V, 50/60 Hz; DC 80 V
(higher DC ratings to special order)
Current ratings
0.02...50 A 1-pole (40 + 50 A DC only)
0.02...30 A multipole
Auxiliary circuit
6 A, AC 240 V;
3 A, DC 28 V
1 A, DC 65 V;
0.5 A, DC 80 V
Typical life
3 AC 415 V, AC 240 V:
0.02...30 A
6,000 operations at 1 x I
N
, inductive
10,000 operations at 1 x I
N
, resistive
DC 80 V: 0.02...25 A
6,000 operations at 1 x I
N
, inductive
0.02...30 A
10,000 operations at 1 x I
N
, resistive
40 + 50 A
6,000 operations at 1 x I
N
, resistive
Ambient temperature
-40...+85 °C (-40...+185 °F)
Insulation co-ordination
rated impulse
pollution
(IEC 60664 and 60664A)
withstand voltage
degree
2.5 kV
2
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A) test voltage
operating area
AC 3,000 V
pole to pole
(2- and 3-pole)
AC 1,500 V
main to auxiliary circuit AC 3,000 V
switching to trip circuit AC 1,500 V (version -X)
Insulation resistance
> 100 MΩ (DC 500 V)
1,200 A at AC – 2,000 A at DC
Interrupting capacity I
cn
0.02...20 A
25...30 A
Interrupting capacity
I
N
(UL 1077)
AC:
1-pole AC 250 V/3,500A AC 250 V/3,500A
2-pole
3-pole
1-pole
2-pole
AC 250 V/3,500A
3AC 250V/3,500A
0.02...50 A
0.02...30 A
AC 250 V/5,000A
3AC250V/5,000A
DC 80 V/3,500 A
DC 80 V/3500 A
3
DC:
Interrupting capacity
(UL 489A)
Degree of protection
(IEC 60529/DIN 40050)
Vibration
with toggle down:
2,000 A
operating area IP40
terminal area IP00
Corrosion
Humidity
Mass
96 hours at 5 % salt mist
to IEC 60068-2-11, test Ka
240 hours at 95 % RH
to IEC 60068-2-78, test Cab
approx. 65 g per pole
10 g (57-2000Hz) ± 0.76 mm (10-57 Hz)
at 0.9 x I
N
directions 1, 2, 3, 4, 5: 10 g (57-2000 Hz) at 1 x I
N
.
with curves F1, F2 in all planes:
10 g (57-2000 Hz) ± 0.76 mm (10-57 Hz)
at 0.8 x I
N
,
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
Shock
100 g (11 ms) at 1 x I
N
, directions 1,2,3,4,5
100 g (11 ms) at 0.8 x I
N
, direction 6.
with curves F1, F2:
100 g (11 ms) at 0.8 x I
N
to IEC 60068-2-27, test Ea
Issue C
www.e-t-a.com
3
- 19
Improved debugging of multithreaded applications (version 10)
For more details, please see the PDF file:...
520spxiong PCB Design
begE-book or other driver introductory tutorial
I only downloaded the PDF of Chapter 1 and Chapter 17. I have been looking for other chapters for a long time but can't find them. Does anyone have the electronic version of other chapters? Or other e...
safasfasffsa Embedded System
How to prevent a brief low level at port P1 when 51 is powered on?
I remember it seemed to be to modify the startup code, is there any other way?...
彪哥 51mcu
Using Ultra Librarian to create Cadence schematics and PCB footprints
[i=s]This post was last edited by nemo1991 on 2017-7-29 22:05[/i] [align=left][color=rgb(51, 51, 51)][font="]The production of component packages is the first step in schematic and PCB design. It is f...
nemo1991 PCB Design
The second sleepless night, is there~~~~
[i=s] This post was last edited by paulhyde on 2014-9-15 04:01 [/i] All my comrades who are still fighting for the e-sports competition, please remember to take care of your health~~~:)The game is alr...
潜水不冒泡 Electronics Design Contest
QEI interface initialization problem of dsPIC30F2010
The encoder AB phase signal enters the dsPIC30F2010 through 74HC14. The hardware is tested with an AB phase signal with a frequency of 100kHz. The QEA and QEB pins of the dsPIC30F2010 are measured. Th...
犹豫的大三 Microchip MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 221  1429  1238  1024  614  5  29  25  21  13 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号