EEWORLDEEWORLDEEWORLD

Part Number

Search

410-K-1-01-SI-10A

Description
cir brkr 10a 240vac 110vdc
CategoryCircuit protection   
File Size308KB,4 Pages
ManufacturerE-T-A [E-T-A Circuit Breakers]
Environmental Compliance  
Download Datasheet View All

410-K-1-01-SI-10A Online Shopping

Suppliers Part Number Price MOQ In stock  
410-K-1-01-SI-10A - - View Buy Now

410-K-1-01-SI-10A Overview

cir brkr 10a 240vac 110vdc

High Performance Thermal-Magnetic Circuit Breakers 410/520/530-...
Description
Single, double and three pole high performance thermal-magnetic
circuit breakers with tease-free, trip-free, snap action mechanism and
toggle actuation (S-type TM CBE to EN 60 934; also to EN 60 947).
Designed for rail, panel or surface mounting. Available with a choice
of characteristic curves and optional auxiliary contacts.
Typical applications
Motors, generators, transformers, thyristors and silicon rectifiers.
Interrupting capacity to IEC 60947/EN 60947
AC voltage
Number
of poles
Voltage
rating
Interrupting
capacity IN
IN 12...125 A
1
2
3
AC 240 V
AC 240 V
3 AC 415 V
5,000 A
8,000 A
5,000 A
cosϕ = 0.7
cosϕ = 0.7
cosϕ = 0.7
DC voltage
Number
of poles
Voltage
rating
Interrupting
capacity IN
IN 12...125 A
Time
constant
IN 7 + 10 A
Interrupting
capacity IN
Time con-
stant
Power
factor
Interrupting
capacity IN
IN 7 + 10 A
3,500 A
6,000 A
3,000 A
cosϕ = 0.8
cosϕ = 0.7
cosϕ = 0.85
Power factor
410-...
Technical data
Voltage rating
Current rating range
curves 01, 02, 04, 05:
curves B3, C3, 01:
Auxiliary circuit
Typical life
Ambient temperature
Insulation co-ordination
(IEC 60664 and 60664A)
Dielectric strength
(IEC 60664 and 60664A)
operating area
pole/pole
main circuit/aux.circuit
aux. circuit 11-12/13-14
Insulation resistance
Degree ef protection
(IEC 60529/DIN 40050)
Vibration
curves 02, 04, 05, B3, C3:
curve 01:
530-...
AC 240 V; 3 AC 415 V; 3 AC 500 V
DC 110 V
10...125 A (EN 60947)
7...100 A (EN 60898)
6 A, AC 240 V or DC 28 V
1 A, DC 110 V
10,000 operations at 1 x I
N
20,000 operations mechanical
-40...+60 °C (-40...+140 °F)
rated impulse
pollution
withstand voltage
degree
6 kV
3
test voltage
AC 3,300 V
AC 3,300 V
AC 2,200 V
AC 1,000 V
> 100 MΩ (DC 500 V)
operating area IP40
terminal area IP00
4 g (60-500 Hz), ± 0.30 mm (10-60 Hz)
3 g (60-500 Hz), ± 0.23 mm (10-60 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
50 g (11 ms) directions 1, 2, 3, 4, 5
30 g in direction 6
30 g (11 ms) in directions 1, 2, 3, 4, 5
20 g in direction 6
to IEC 60068-27, test Ea
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
240 hours at 95 % RH
to IEC 60068-2-3, test Ca
410 (1-pole): approx. 290 g
520 (2-pole): approx. 580 g
530 (3-pole): approx. 870 g
1
1
2
2
DC 110 V
DC 110 V
DC 110 V
DC 110 V
3,000 A
5,000 A
5,000 A
10,000 A
13 ms
5 ms
13 ms
≈ 0 ms
3,000 A
L/R = 5 ms
3,000 A
L/R = 5 ms
Standard current ratings and typical internal resistance values
Curves 01, 02, 04, 05:
Current
rating (A)
10
16
20
25
32
40
50
63
80
90
100
125
Internal resistance
(Ω) per pole
0.033
0.015
0.010
0.0062
0.0039
0.0031
0.0022
≤ 0.002
≤ 0.002
≤ 0.002
≤ 0.002
≤ 0.002
Curves B3, C3:
Current
rating (A)
7
10
12
16
20
25
32
40
50
63
80
100
Internal resistance
(Ω) per pole
0.033
0.015
0.015
0.010
0.0062
0.0039
0.0031
0.0022
≤ 0.002
≤ 0.002
≤ 0.002
≤ 0.002
5
Shock
curves 02, 04, 05, B3, C3:
curve 01:
Corrosion
Humidity
Mass
Approvals
Authority
UL
Standard
UL 1077
C22.2 No 235
Rated voltage
AC 277 V
Current ratings
7...125 A (type 520)
2015/16
www.e-t-a.de
5
- 13

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2417  1835  1710  1779  1928  49  37  35  36  39 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号