EEWORLDEEWORLDEEWORLD

Part Number

Search

8340-F110-K4F2-A3H0-40A

Description
cir brkr mag 40a 240vac 80vdc
CategoryCircuit protection   
File Size455KB,6 Pages
ManufacturerE-T-A [E-T-A Circuit Breakers]
Environmental Compliance  
Download Datasheet View All

8340-F110-K4F2-A3H0-40A Online Shopping

Suppliers Part Number Price MOQ In stock  
8340-F110-K4F2-A3H0-40A - - View Buy Now

8340-F110-K4F2-A3H0-40A Overview

cir brkr mag 40a 240vac 80vdc

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...
Description
Single and multipole magnetic circuit breakers with trip-free mechanism
and toggle actuation. A choice of fast magnetic only or hydraulically
delayed switching characteristics (S-type MO or HM CBE to EN 60934)
ensures suitability for a wide range of applications. Industry standard
dimensions and panel mounting. Options include auxiliary changeover
contacts, or relay trip function. Low temperature sensitivity at rated load.
Approved to CBE standard EN 60934 (IEC 60934).
Typical applications
Control equipment, communications systems, transportation, power
supplies.
1-pole
Standard current ratings and typical internal resistance values
8340-F...
2-pole
Technical data
Current
rating (A)
0.02
0.05
0.1
0.25
0.5
0.75
1
2
2.5
3
5
6
8
10
12
15
16
20
25
30
40
50
Curves and internal resistance per pole (Ω)
F1
F2
K1, M1, T1, K2, M2, T2
1493
276
58
8.2
2.3
0.98
0.58
0.145
0.096
0.065
0.025
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
≤ 0.01
≤ 0.01
953
152
37
6.0
1.47
0.63
0.35
0.096
0.061
0.048
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
-
-
2669
452
100
15.5
3.9
1.65
0.95
0.26
0.15
0.10
0.042
0.029
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
≤ 0.01
≤ 0.01
2457
376
94
14.7
3.2
1.56
0.90
0.20
0.15
0.10
0.040
0.028
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
< 0.02
-
-
For further details please see chapter: Technical Information
Voltage rating
3 AC 415 V; AC 240 V, 50/60 Hz; DC 80 V
(higher DC ratings to special order)
Current ratings
0.02...50 A 1-pole (40 + 50 A DC only)
0.02...30 A multipole
Auxiliary circuit
6 A, AC 240 V;
3 A, DC 28 V
1 A, DC 65 V;
0.5 A, DC 80 V
Typical life
3 AC 415 V, AC 240 V:
0.02...30 A
6,000 operations at 1 x I
N
, inductive
10,000 operations at 1 x I
N
, resistive
DC 80 V: 0.02...25 A
6,000 operations at 1 x I
N
, inductive
0.02...30 A
10,000 operations at 1 x I
N
, resistive
40 + 50 A
6,000 operations at 1 x I
N
, resistive
Ambient temperature
-40...+85 °C (-40...+185 °F)
Insulation co-ordination
rated impulse
pollution
(IEC 60664 and 60664A)
withstand voltage
degree
2.5 kV
2
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A) test voltage
operating area
AC 3,000 V
pole to pole
(2- and 3-pole)
AC 1,500 V
main to auxiliary circuit AC 3,000 V
switching to trip circuit AC 1,500 V (version -X)
Insulation resistance
> 100 MΩ (DC 500 V)
1,200 A at AC – 2,000 A at DC
Interrupting capacity I
cn
0.02...20 A
25...30 A
Interrupting capacity
I
N
(UL 1077)
AC:
1-pole AC 250 V/3,500A AC 250 V/3,500A
2-pole
3-pole
1-pole
2-pole
AC 250 V/3,500A
3AC 250V/3,500A
0.02...50 A
0.02...30 A
AC 250 V/5,000A
3AC250V/5,000A
DC 80 V/3,500 A
DC 80 V/3500 A
3
DC:
Interrupting capacity
(UL 489A)
Degree of protection
(IEC 60529/DIN 40050)
Vibration
with toggle down:
2,000 A
operating area IP40
terminal area IP00
Corrosion
Humidity
Mass
96 hours at 5 % salt mist
to IEC 60068-2-11, test Ka
240 hours at 95 % RH
to IEC 60068-2-78, test Cab
approx. 65 g per pole
10 g (57-2000Hz) ± 0.76 mm (10-57 Hz)
at 0.9 x I
N
directions 1, 2, 3, 4, 5: 10 g (57-2000 Hz) at 1 x I
N
.
with curves F1, F2 in all planes:
10 g (57-2000 Hz) ± 0.76 mm (10-57 Hz)
at 0.8 x I
N
,
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
Shock
100 g (11 ms) at 1 x I
N
, directions 1,2,3,4,5
100 g (11 ms) at 0.8 x I
N
, direction 6.
with curves F1, F2:
100 g (11 ms) at 0.8 x I
N
to IEC 60068-2-27, test Ea
Issue C
www.e-t-a.com
3
- 19
I'm studying BQ76940 recently and want to develop a BMS. I've been looking for information and encountered some questions during the process.
I have been studying the BQ76940 material recently and want to develop a BMS. I have been looking for information and encountered some questions in the process. Here is a link to the BQ76940 specifica...
QWE4562009 Discrete Device
Please come in and see what software is generally needed to make a clock, what should I learn, I don't know anything.
There is still one month left before the class starts, and I still don’t know how to make a clock, or what is needed to make a clock......
小小耗子 51mcu
pt2314 related questions
A great man on the forum contributed the pt2314 program, as shown in the attachment. I use proteus to simulate it, but it doesn't work. Logically, text should appear when simulating 51+1602, but nothi...
windyde 51mcu
2812 register assignment question!!!
1. PieCtrlRegs.PIEIER1.bit.INTx6 = 1; // Enable PIE INT1.6 = ADCINTThis sentence implements Uint16 INTx6 = 1; How does it implement the assignment of register PIEIER1 in hardware?2. typedef interrupt ...
vv2007 Microcontroller MCU
[Sipeed LicheeRV 86 Panel Review] 4. Building a cross-compilation environment
[i=s]This post was last edited by sonicfirr on 2022-3-12 13:08[/i]There is a small pit in setting up the Linux cross-toolchain compilation environment for the 86 board. After many attempts, I successf...
sonicfirr Domestic Chip Exchange
DNW does not display startup information after the 2440 board is powered on
A newbie's help: I just bought a 2440 board. COM1 and USE are both shown as connected on DNW. But after powering on, DNW should display the startup information and then allow the user to enter LINUX. ...
情场探花 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 114  2314  346  1559  1111  3  47  7  32  23 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号