Part Number

Search

F384103C1.0

Description
Barrier Strip Terminal Block, 30A, 1 Row(s), 1 Deck(s)
CategoryThe connector    terminals   
File Size208KB,1 Pages
ManufacturerCooper Industries
Download Datasheet Parametric View All

F384103C1.0 Overview

Barrier Strip Terminal Block, 30A, 1 Row(s), 1 Deck(s)

F384103C1.0 Parametric

Parameter NameAttribute value
MakerCooper Industries
Reach Compliance Codeunknown
ECCN codeEAR99
Fastening methodSCREW
Manufacturer's serial numberF38
Installation typePANEL
Number of layers1
Rows1
Number of channels3
Rated current30 A
Rated voltage300 V
safety certificateUL; CSA; CE
Terminal and terminal strip typesBARRIER STRIP TERMINAL BLOCK
Wire gauge10 AWG
Base Number Matches1
F38 Series Filtered Terminal Blocks
SPECIFICATIONS
Ratings:
30A, 240VAC, 300VDC.
Center Spacing:
0.437" or 7/16" (11.10mm)
Wire Size:
# 10-22 AWG CU
Screw Size:
# 8-32 (# 6-32 available, consult factory)
Torque Rating:
15 in-lb.
Operating Temperature:
–55°C to +105°C.
Housing Material:
94VO Thermoplastic.
Molded Material:
Black, UL rated 94V0 thermoplastic.
Terminal Material:
Brass, Tin-Plated
Capacitance:
1,000 pF to 5,000 pF in either C or Pi Schematic
Dielectric Withstanding Voltage:
1000 VAC; 1700VDC
D.C. Resistance:
0.01 ohms max.
Agency Information:
UL/CSA, CE Certified
# of
Poles
2
3
4
5
6
7
8
A
A
Front Mount Rear Mount
1.67
2.10
2.54
2.98
3.41
3.85
4.29
1.88
2.32
2.76
3.19
3.63
4.07
4.51
B
C
D
FEATURES
• Rugged integrated construction of filtering elements
around a solid brass pin provides excellent EMI/RFI
filtering
• Filter element provides high insertion loss for EMI/RFI
filtering of AC and DC power and control lines
• 2 to 8 terminals standard – up to 16 poles available
• Cost-effective EMI solution for industrial interconnec-
tion filtering
• Termination options are straight lead, male or female
quick connect
• Custom and special options available including:
– Different capacitance values on each position
– Wire assemblies added to pins
Insertion Loss for 2,500 pF Pi Schematic
Typical Insertion Loss (dB) in 50 Ohm Circuit
30MHz . . . . . . . . . . .42 dB
50 MHz . . . . . . . . . . .45 dB
100 MHz . . . . . . . . . .50 dB
300 MHz . . . . . . . . . .68 dB
1000 MHz . . . . . . . . .70 dB
Single & Double Row
Filtered Connectors
Euro-MAG Series
PCB – Spring Clamp
1.31
1.75
2.19
2.63
3.06
3.50
3.94
0.93
1.37
1.81
2.25
2.68
3.12
3.56
0.44
0.88
1.31
1.75
2.19
2.62
3.06
* Note: For other capacitance insertion loss, consult factory.
* Note: In inches. Available up to 16 poles. Consult factory.
O - Front Panel Mount
I - Rear Panel Mount
Base & Rail Mount
Connectors
Power Distribution Blocks
Part Numbering System
Series
Terminal Style
Mounting
# of Poles
Screw Options
Inches (Millimeters)
Filter Options
Capacitance
F 3 8
0
- straight lead
0
- front panel mount
02
to
08*
1
- 0.187" quick
with mount ends
connect (male)
1
- rear panel mount
2
- 0.187" quick
with #4-40 threaded inserts
connect (male)
3
- 0.250" quick
connect (male)
4
- 0.250" quick
connect (female)
Blank
- #8-32, steel, zinc plated
philslot BHMS (stnadard)
04
- #8-32, brass, nickel plated
philslot BHMS
92
- #8-32, steel, zinc plated
slotted BHMS
94
- #8-32, brass, nickel plated
slotted BHMS
C
- C Filter
P
- Pi Filter
.
1.0
- 1,000 pF + 100%-0%
2.5
- 2,500 pF + 100%-0%
5.0
- 5,000 pF + 100%-0%
WIRE MANAGEMENT PRODUCTS
* Note: Standard is 02-08 poles. Available up to 16 poles. Consult factory for availability.
Special electrical/mechanical configurations are available upon request from factory.
25
Implementation of TCP/IP protocol stack on MSP430 microcontroller
[p=30, null, left][font=宋体][font=Verdana][size=3][color=#000000] With the continuous development of information technology and the improvement of people's requirements for comfort and convenience in d...
fish001 DSP and ARM Processors
CYCLONE2 Configuration and Interface
I would like to ask experienced friends: 1. Does (ep2c5t144i8) need to be connected to an external SRAM to work? 2. How to convert the level when the output of the 5V chip is used as input to the IO p...
zdh09 Embedded System
How do you calculate the antenna length? And the style?
How do you calculate the antenna length? And the style?...
鸿鹰 RF/Wirelessly
LM2585 Typical Application
I want to use the LM2585 typical application circuit, input 24V, and convert it to positive and negative 12V power supply. I would like to ask if the 1:1.2 in the red circle is an isolation transforme...
LL58189034 Power technology
Generate various waveform programs using DDS_AD9854
Generate various waveforms with DDS_AD9854.pdf...
w123b456 Electronics Design Contest
Italian supermarkets' imaginative advertising
[size=16px][img]http://bbs.ad.hc360.com/bbs/Upload/Image/ad/200598113423979.jpg[/img] [align=left][img]http://bbs.ad.hc360.com/bbs/Upload/Image/ad/200598113314338.jpg[/img] [/align][color=red][size=9p...
lijiaoeeworld Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2594  1364  2812  1751  1437  53  28  57  36  29 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号