EEWORLDEEWORLDEEWORLD

Part Number

Search

170M4117

Description
Electric Fuse, 700A, 700VAC, 200000A (IR), Inline/holder,
CategoryCircuit protection    Circuit protection   
File Size202KB,4 Pages
ManufacturerCooper Industries
Environmental Compliance
Download Datasheet Parametric View All

170M4117 Online Shopping

Suppliers Part Number Price MOQ In stock  
170M4117 - - View Buy Now

170M4117 Overview

Electric Fuse, 700A, 700VAC, 200000A (IR), Inline/holder,

170M4117 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompli
body width53 mm
body height53 mm
Body length or diameter50 mm
Built-in featuresINDICATOR
Circuit protection typeELECTRIC FUSE
Joule integral nominal69500 J
Manufacturer's serial number170M
Installation featuresINLINE/HOLDER
method of packingBOX
physical size50mm x 53mm x 53mm
Rated breaking capacity200000 A
Rated current700 A
Rated voltage (AC)700 V
GuidelineCE; DIN 43653; IEC; UL
surface mountNO
Terminal shapeTAB/BLADE
Base Number Matches1
High Speed Fuses
Square body DIN 43 653 — 690V/700V (IEC/UL):
40-2000A
690V/700V (IEC/UL) 40-2000A
Specifications
Description: Square body DIN 43-
653 stud-mount high speed fuses.
Dimensions:
See dimensions
illustration.
Ratings:
Volts: —
Amps: —
IR: —
690Vac (IEC)
700Vac (UL)
40-2000A
200kA RMS Sym.
Arc Voltage
This curve gives the peak
arc voltage, UL, which may
appear across the fuse
during its operation as a
function of the applied
working voltage, Eg, (rms)
at a power factor of 15%.
Power Losses
Watts loss at rated current
is given in the electrical
characteristics. The curve
allows the calculation of
the power losses at load
currents lower than the
rated current. The correc-
tion factor, Kp, is given as
a function of the RMS load
current, Ib, in % of the
rated current.
1.4
1.2
10
3
9
8
7
6
5
4
3
200
300
400
500
E
g
600 690
U
L
1.0
K
p
0.8
0.6
0.5
0.4
0.3
0.2
Agency Information:
CE, Designed and tested to IEC
60269: Part 4, UL Recognized. Consult Cooper Bussmann for
UL Recognition/CSA Component Acceptance status.
Electrical Characteristics
Total Clearing I
2
t
The total clearing I
2
t at rated voltage and at power factor of
15% are given in the elec-
1.5
K
trical characteristics. For
2) 1)
other voltages, the clearing
1.0
I
2
t is found by multiplying
by correction factor, K,
0.5
given as a function of
0.4
applied working voltage,
0.3
Eg, (rms).
0.2
E
g
100 200 300 400 500 600 690
1) Rated voltage 600V.
2) Rated voltage 550V
0.1
30 40 50
60
70
I
b
80 90 100%
Features and Benefits
• Excellent dc performance
• Low arc voltage and low energy let-through (I
2
t)
• Low watts loss
• Superior cycling capability
Typical Applications
• DC common bus
• DC drives
• Power converters/rectifiers
• Reduced voltage starters
Dimensions (mm)
Type -KN/80, -KN/110
Size
1*
1
2
3
A
50
50
50
51
B
104
108
108
109
B**
134
138
138
139
C
78
78
78
78
C**
108
108
108
108
D
59
69
77
92
E
45
53
61
76
H
22
25
25
30
C
A
H
**Valid for fuse type -KN/110.
1mm = 0.0394” / 1” = 25.4mm
11
D
E
B
6
E
118
For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2401  1981  202  2060  1170  49  40  5  42  24 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号