EEWORLDEEWORLDEEWORLD

Part Number

Search

P8-312611G

Description
Pushbutton Switch
CategoryMechanical and electronic products    switch   
File Size1004KB,2 Pages
ManufacturerOTTO
Websitehttp://www.ottoexcellence.com
Environmental Compliance
Download Datasheet Parametric View All

P8-312611G Overview

Pushbutton Switch

P8-312611G Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Reach Compliance Codeunknow
Base Number Matches1
P8
COMPACT
PUSHBUTTONS
COMPACT PUSHBUTTONS
MOMENTARY OR PUSH-PULL ACTION, SHORTER BEHIND PANEL, SUBMINIATURE DOUBLE BREAK
Makes and breaks every time!
OTTO’s inherent rocking action
breaks welds and wipes contacts clean.
The P8 series pushbutton switches feature a shortened
back panel depth while offering all the features of the regular
size P1 and P3 series switches. P8 series switches offer
vastly improved electrical and mechanical life under extreme
conditions found in most military and industrial environments.
On sealed models, a silicone boot operating on our patented
“rolling sleeve” principle protects the contact area against
contamination at the button area. This boot provides long life
and smooth operation over a wide temperature range. Sealed
terminals protect the contact area from hostile environments
and solder flux on both sealed and unsealed models.
High contact force (120g/4.2 oz), low contact resistance
(25mΩ max) and short contact bounce are the result of our
snap-action mechanism. These characteristics guarantee
exceptional current carrying capabilities over the life of the
switch. With the optional low level configuration the P8 is well
suited to interface directly to computers and other solid state
devices.
The P8 series is a quality precision snap-action switch designed
for use in panel boards, control sticks, computers, instruments,
pressure switches and other hand or machine operated
applications where rugged pushbutton switches are required.
In addition, its precision permits the OTTO P8 to also be used
as a limit switch. The P8 offers unique size, high electrical
ratings and a wide choice of mounting styles.
Style
P8-8
Style
P8-3
Style
P8-1
Style
P8-5
Style
P8-6
Style
P8-4
Style
P8-7
®
C
US
Standard Characteristics/Ratings:
ELECTRICAL RATINGS:
Load
Resistive
Inductive
Lamp
DWV
Low Level
Electrical Life:
Mechanical Life:
Seal:
Operating Force:
Total Travel:
Overtravel:
Sea Level @
28VDC or 115VAC, 60/400Hz
10A
5A
3A
1050Vrms
10mA @ 30mV
100,000 cycles (25,000 low level)
1,000,000 cycles
IP64 or IP68S
2.5 lbs. +0.5 /-1.0 lb. or 4.0 lbs. +/- 1.0 lb.
0.085 +/- 0.015 inches
0.012 inches min
Features:
Shorter behind panel depth than OTTO’s P1/P3
Patented “rolling sleeve” button seal
Contact area sealed at button & terminals
Positive tactile feedback
Variety of mounting styles
Variety of button lengths & shapes
Engraved buttons & bezels available
Mechanical life 1 million cycles
UL recognized & CSA certified
Sealed to IP64 or IP68S
RoHS/WEEE/Reach compliant
Operating Temp Range:
-55°C to +85°C
MATERIALS:
Case:
Button:
Terminals:
Terminal Hardware:
Mounting Hardware:
Anodized aluminum alloy
Thermoplastic
Brass with silver or brass with gold over silver for low level
Terminal lugs, screws and lockwasher where applicable
Hex nut, lockwasher, panel seal gasket when applicable
150
OTTO Full Line Catalog
Specifications Subject To Change Without Notice
Review summary: Anxinke NB-IoT development board EC-01F-Kit
Event details: [Anxinke NB-IoT development board EC-01F-Kit]Updated to 2021-12-11Evaluation report summary:@kit7828[Anxinke NB-IoT Development Board EC-01F-Kit] 1. Unboxing and Hardware Appreciation@秦...
EEWORLD社区 Special Edition for Assessment Centres
How does IAR compiler set a function in a source file to compile at the starting address?
How to set IAR compiler to compile a function of a source file at the starting addressI am using STM32 M3 chipFor exampleI want to compile the main function of main.c at the starting address.How shoul...
虾段 stm32/stm8
The positive and negative input terminals of the isolation op amp are connected to a solid-state relay respectively. I wonder if it will have any impact on the acquisition?
The positive and negative input terminals of the isolation op amp are respectively connected to a solid-state relay to control whether the signal to be collected is connected to the isolation op amp, ...
milan111 MCU
Supplement to [Help: 220V to 5V power supply circuit]!
[size=5][color=red] Intense competition leads to more hidden safety hazards! [/color][/size] The competition in the electronics industry is getting more and more fierce. Many manufacturers, especially...
czc568 Power technology
What is the difference between LCD DE mode H/V mode?
As title...
6855391 Embedded System
How to extract the touch screen calibration program of wince independently?
I want to support calibration programs in multiple languages in the system, and then call them directly in the application according to the language, without calling the dll. In this way, my system ca...
天天 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2081  1896  139  2334  881  42  39  3  47  18 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号