LCS052T13PD20EW

Description
SNAP ACTING/LIMIT SWITCH, SPST, MOMENTARY, 7.9mm, THROUGH HOLE-STRAIGHT, ROHS COMPLIANT
CategoryMechanical and electronic products    switch   
File Size326KB,4 Pages
ManufacturerC&K Components
Environmental Compliance  
Download Datasheet Parametric View All

LCS052T13PD20EW Overview

SNAP ACTING/LIMIT SWITCH, SPST, MOMENTARY, 7.9mm, THROUGH HOLE-STRAIGHT, ROHS COMPLIANT

LCS052T13PD20EW Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Objectid1084429638
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
Country Of OriginMainland China
ECCN codeEAR99
YTEOL8.2
Actuator stroke7.9 mm
Actuator typeLEVER
body width6.4 mm
body height9.8 mm
Body length or diameter19.8 mm
Contact (AC) maximum rated R load6A@250VAC
Maximum contact current (AC)6 A
Maximum contact voltage (AC)250 V
Electrical life10000 Cycle(s)
Installation featuresTHROUGH HOLE-STRAIGHT
Maximum operating force1.99 N
Maximum operating temperature125 °C
Minimum operating temperature-40 °C
Maximum pre-travel6.3 mm
sealIP67
surface mountNO
Switch actionMOMENTARY
switch functionSPST
Switch typeSNAP ACTING/LIMIT SWITCH
Termination typeSOLDER
LCS Series
Subminiature Sealed Snap-acting Switches
Features/Benefits
Compact design
Long life and high electrical capacity
Quick connect, solder terminals,
PC terminals, wire leads
Wide variety of actuator styles
RoHS compatible, RoHS compliant
IP67
Specifications
CONTACT RATING: 6 AMP, 250 V AC and
5 AMP, 125/250 V AC
0.1 AMP, 125/250 V AC
ELECTRICAL LIFE: 10,000 cycles
INSULATION RESISTANCE: 100 M ohm min.
DIELECTRIC STRENGTH: 1,000 VAC
OPERATING TEMPERATURE:
-40ºC to +120ºC (without wire)
-40ºC to +85ºC (with UL1007 wire)
-40ºC to +105ºC (with UL1015 wire)
-40ºC to +105ºC (with UL1430 wire)
-40ºC to +80ºC (with UL1061 wire)
-40ºC to +120ºC (with UL1330 wire)
OPERATING FORCE: (see ACTUATOR’S option sections).
MOUNTING: 2-56 screws, torque 2.3 in/lbs max.
NOTE:
Specifications and materials listed above are for switches with standard options.
For information on specific and custom switches, consult Customer Service center.
14
Typical Applications
Motorized equipment
Sump pump
Thermostatic controls
Computers
Air conditioners
14
Materials
SWITCH HOUSING: Thermoplastic polyester or high temperature
thermoplastic (PTS) (UL 94V-0).
ACTUATOR BUTTON: Thermoplastic polyester.
SPRING: Copper alloy.
PIVOT: Copper alloy.
MOVABLE CONTACTS: Silver nickel
STATIONARY CONTACTS: Silver nickel on copper alloy.
TERMINALS: Copper alloy.
ACTUATOR LEVEL: Stainless steel.
J
Snap-acting
Build-A-Switch
To order, simply select desired option from each category and place in the appropriate box. Available options are shown and
described on pages J-27 thru J-29. For additional options not shown in catalog, consult Customer Service Center.
L
Series
LCS
Contact Rating
05
5 AMP, 125/250 V AC
6 AMP, 250 V AC
01
0.1 AMP, 125/250 V AC
C
S
14
Operating Force
1
150 grams
2
203 grams
Actuator
P00
Pin plunger
T00
11.9 mm short lever
T05
17.4 mm short lever
T07
19.4 mm short lever
T13
25.5 mm lever
T19
33.3 mm lever
T28
40.7 mm lever
T43
55.9 mm lever
S26
18.6 mm simulated lever
A05
17.2 mm lever roller
Circuitry
C
SPDT
W
SPST N.C.
Y
SPST N.O.
Wire Type AWG
20
20 AWG
22
22 AWG
24
24 AWG
26
26 AWG
28
28 AWG
30
30 AWG
Wire UL #
(when required)
A
UL1007
B
UL1015
C
UL1430
D
UL1061
E
UL1330
Terminations
S
Solder
Q
0.110 Quick Connect
P
PC Thru Hole
W
Wire leads potted
Z
Wire leads non-potted
Wire Side (when required)
A
Wire out the bottom
B
Wire out the right side
C
Wire out the left side
D
None
Dimensions are shown: mm
Specifications and dimensions subject to change
J–26
www.ck-components.com
See what kind of engineer you are???
[color=#3366cc]Repost: Comments from female engineers[/color] I saw this post on a website and found it very interesting. It is also effective for us PLC system developers. Let's share it! It seems th...
天使疯子 Embedded System
[Showing off the classics] I personally think this circuit is super classic!
[i=s]This post was last edited by dontium on 2015-1-23 13:07[/i]The circuit to be analyzed is as follows. I think this circuit is very classic. The main task of this circuit is to monitor the current ...
37°男人 Analogue and Mixed Signal
【Low Power】Optimization Methods for Low Power FPGA Electronic Systems
First, the power consumption of the FPGA is compared with the actual system power consumption, and the accuracy of the FPGA power consumption estimation tool XPower in the ISE software package of Xili...
cillyfly FPGA/CPLD
[Hua Diao Experience] 20 Music Visualization: A Series of Trials with ESP32_C3 and WS2812B
[i=s]This post was last edited by eagler8 on 2022-7-19 06:13[/i]The MAX9814is a low-cost, high-performance microphone amplifier with automatic gain control (AGC) and low-noise microphone bias. The dev...
eagler8 DIY/Open Source Hardware
One week evaluation information delivered on time~
Hello, everyone~ The weekly review information is here again~ This weekend is Qingming Festival, what are your plans? Because of the epidemic, we don’t plan to travel out of the province. During Qingm...
okhxyyo Special Edition for Assessment Centres
51 register group problem
There are 4 register groups in 51's RAM. You can set which register group to use through PSW, and then the other register groups can be used as ordinary memory. My question is why there are four regis...
skingshere Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2070  2590  2127  1697  1413  42  53  43  35  29 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号