EEWORLDEEWORLDEEWORLD

Part Number

Search

FN3450-250-118-E0XXJRX

Description
Three Phase EMI Filter,
CategoryAnalog mixed-signal IC    filter   
File Size3MB,8 Pages
ManufacturerSchaffner
Download Datasheet Parametric View All

FN3450-250-118-E0XXJRX Overview

Three Phase EMI Filter,

FN3450-250-118-E0XXJRX Parametric

Parameter NameAttribute value
MakerSchaffner
Reach Compliance Codecompliant
filter typeTHREE PHASE EMI FILTER
Base Number Matches1
DATASHEET
Evo line (5% THID) FN 3450
Ecosine evo, 50 Hz Passive Harmonic Filters
The industry standard for 6-pulse rectifier and
motor drives
Filters for diode rectifier without DC-link choke
and thyristor rectifier
Best-in-class partial load performance
Most compact design
Plug and play, ready to use
Approvals
(depending on filter configuration)
Features and benefits
Schaffner ecosine harmonic filters represent an
economical solution to the challenge of load-applied
harmonics mitigation in three-phase power systems.
With a plug-and-play approach and more compact
dimensions than comparable products, they can be
quickly installed and easily commissioned. They
increase the reliability and service life of electric
installations, help utilize electric sytem capacity
better, and are the key to meet Power Quality
standards such as IEEE 519. Ecosine filters reshape
your distorted current back to the desired sinusoidal
waveform. Schaffner ecosine filters can be applied to
virtually any kind of power electronics with front-end
six-pulse rectifiers, 3-phase diode or thyristor bridges,
where harmonic current distortion needs to be
reduced to defined limits.
Technical specifications
Nominal operating voltage
Operating frequency
Nominal motor drive input power rating
Total harmonic current distortion THID*
Efficiency
High potential test voltage
Protection category
Cooling
Overload capability
Ambient temperature range
3 x 440 VAC to 500 VAC ±10%
50 Hz ±1 Hz
1.1 to 250 kW
<5% at rated power
>98% for rated voltage and power
P –> E 2160 VAC (1 s)
IP 00, IP 20
Internal fan cooling or external cooling**
1.6x rated current for 1 minute, once per hour
–25°C to +45°C fully operational
+45°C to +70°C derated operation***
–25°C to +85°C transport and storage
UL 94 V-2
Filter: UL 61800-5-1, EN 61800-5-1
Chokes: EN 61558-2-20 or EN 60076-6
>200,000 hours
100 kA
TN, TT, IT
OV III (IEC 60664-1 / UL 61800-5-1)
Typical applications
Equipment with front-end six-pulse rectifier
Motor drives
Factory automation equipment
Water/wastewater treatment facilities
Fan and pump applications
HVAC installations
Mission-critical processes
DC fast chargers
Flammability corresponding to
Design corresponding to
MTBF @ 45°C/500 V (Mil-HB-217F)
SCCR****
Earthing System
Overvoltage category
Typical electrical schematic
****System requirements: THVD <2%, line voltage unbalance <1%
** *
Note: performance specifications in this brochure refer to six-pulse diode rectifiers.
****SCR
rectifier front-ends will produce different results, dependent upon the firing angle of the thyristors.
THID ~5% at rated power for filter <6 kW
** Please check the inlet air flow required for cooling table on page 6 of this document.
*** I
derated
= I
nominal
*√((T
max-
T
amb
)/(T
max-
T
nominal
)) = I
nom
*√(70°C-T
amb
)/25°C
**** External UL-rated fuses required. Please consult the user manual.
Can any expert provide Mitsubishi or Fanuc PLC software and introductory learning materials? I want to learn
Can anyone provide Mitsubishi or Fanuc PLC software and introductory learning materials? Or the names of good related books. I want to learn some new knowledge recently....
675452482 Industrial Control Electronics
[Silicon Labs BG22-EK4108A Bluetooth Development Evaluation] 3. Lighting Experiment
[i=s]This post was last edited by webber310 on 2022-1-7 19:58[/i]3. Lighting Experiment In the previous article, we introduced the hardware of BG22-EK4108A and the installation of the development envi...
webber310 Development Kits Review Area
CC1310 Two-wire Serial Bootloader Solution
CC1310 is a Sub-1G-capable SOC in TI Simplelink MCU series. In response to the application requirements of many customers who need to upgrade firmware via serial port, CC1310 has a built-in ROM-based ...
Jacktang RF/Wirelessly
Switching Power Supply Design Classic Training
Switching Power Supply Design Classic Training...
Lemontree Analog electronics
Current calculation formula
The current calculation formula is Ia=Ia*100/0*34D1B8*Ka*ct, where Ka is the calibration coefficient 1.2886. Ia*100/0*34D1B8 is not known what it means....
1614048761 MCU
Huawei mobile phone case fill light
Huawei MATE 40 Ring Flash Protective Case Solution_Principle Analysis and Original Disassembly Comparison Recently, Huawei launched a very unique protective case. The highlight of this protective case...
小瑞瑞 PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 525  935  1147  646  2881  11  19  24  14  59 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号