Absolute Maximum Ratings
Parameter
+IN to -IN voltage
PC to -IN voltage
PR to -IN voltage
SC to -OUT voltage
Isolation voltage
IN to OUT
IN to base
OUT to base
Operating Temperature
Storage Temperature
Pin soldering temperature
Mounting torque
Rating
-0.5 to +105
-0.5 to +7.0
-0.5 to +7.0
-0.5 to +1.5
3000
1500
500
-55 to +100
-65 to +125
500 (260)
750 (390)
5 (0.57)
Unit
V
DC
V
DC
V
DC
V
DC
V
RMS
V
RMS
V
RMS
°C
°C
°F (°C)
°F (°C)
in-lbs (N-m)
Test voltage
Test voltage
Test voltage
M-Grade
M-Grade
<5 sec; wave solder
<7 sec; hand solder
6 each
Notes
Product Overview
These DC-DC converter modules use advanced
power processing, control and packaging
technologies to provide the performance,
flexibility, reliability and cost effectiveness of a
mature power component.
High frequency ZCS/ZVS switching provides
high power density with low noise and
high efficiency.
Part Numbering
e.g. V48C12T150BL2
V4 8 C
B
Output Power
P
OUT
50W
75W, 50W
100W, 75W, 50W
100W, 150W
150W, 75W
150W, 75W
150W, 75W
150W, 75W
150W
150W, 75W
Pin Style
Finish
Blank:
Short
Tin/Lead
L:
Long
Tin/Lead
S:
Short ModuMate
Gold
N:
Long ModuMate
Gold
F:
Short RoHS
Gold
G:
Long RoHS
Gold
K:
Extra Long RoHS
Gold
Baseplate
Blank:
Slotted
2:
Threaded
3:
Through-hole
Output Voltage
2
= 2V
3V3
= 3.3V
8
= 8V
5
= 5V
12
= 12V
15
= 15V
24
= 24V
28
= 28V
36
= 36V
48
= 48V
Product Grade Temperatures (°C)
Grade
Operating
Storage
E
=
- 10 to +100
- 20 to +125
C
=
- 20 to +100
- 40 to +125
T
=
- 40 to +100
- 40 to +125
H
=
- 40 to +100
- 55 to +125
M
=
- 55 to +100
- 65 to +125
V
OUT
2V
3.3V
5V
8V
12V
15V
24V
28V
36V
48V
48V Micro Family
Page 1 of 13
Rev 8.6
06/2017
vicorpower.com
800 927.9474
48V Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
29.4
75.7
34.9
30.5
78.8
82.5
2.5
Min
36
Typ
48
Max
75
100
35.7
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
mA
PC pin low
<100ms
Notes
MODULE OUTPUT SPECIFICATIONS
Parameter
Output voltage setpoint
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
10
±0.02
±0.002
±2
Min
Typ
Max
±1%
±0.2
±0.005
±5
110
Unit
%
%
% / °C
%
%
Notes
Of nominal output voltage. Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
+OUT to –OUT — Absolute Maximum Ratings
2V
3.3V
5V
8V
12V
15V
24V
28V
36V
48V
-0.5 to 3.1
-0.5 to 4.7
-0.5 to 7.0
-0.5 to 10.9
-0.5 to 16.1
-0.5 to 20.0
-0.5 to 31.7
-0.5 to 36.9
-0.5 to 47.1
-0.5 to 62.9
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
Note:
The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application
information, please refer to output connections on page 8.
THERMAL RESISTANCE AND CAPACITY
Parameter
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20265)
Baseplate to ambient
Baseplate to ambient; 1000LFM
Thermal capacity
Min
Typ
0.24
0.21
10.9
2.8
48
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
48V Micro Family
Page 2 of 13
Rev 8.6
06/2017
vicorpower.com
800 927.9474
48V Input
Module Family Electrical Characteristics (Cont.)
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Primary Side (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
PC module disable
PC module enable delay
PC module alarm
PC resistance
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Secondary Side (SC = Secondary Control)
SC bandgap voltage
SC resistance
SC capacitance
SC module alarm
1.21
990
1.23
1000
0.033
0
1.25
1010
V
DC
Ω
µF
V
DC
With open trim; referenced to –Sense. See Fig. 7
Referenced to –Sense
0.9
5.7
150
375
2.4
500
2.5
625
2.6
12
1.0
5.9
5.50
1.5
2.3
5.75
2.1
2.6
4
6.00
3.0
2.9
7
0.5
1.1
6.1
V
DC
mA
V
DC
ms
Vavg
MΩ
Volts
mA
Ω
Volts
modules
25°C
Minimum pulse width: 20ns
Without PR buffer amplifier
UV, OV, OT, module fault. See Figs. 3 and 5
See Fig. 3, converter off or fault mode
PR load >30Ω, <30pF
PC current = 1.0mA
PC voltage = 5.5V
Switch must be able to sink
≥4mA.
See Fig. 2
MODULE GENERAL SPECIFICATIONS
Parameter
Isolation test voltage (IN to OUT)*
Isolation test voltage (IN to base)*
Isolation test voltage (OUT to base)*
Isolation resistance
Weight (E, C, T grade)
Weight (H, M grade)
Temperature limiting
Agency approvals
1.9
(52.8)
2.1
(58.7)
100
Min
3000
1500
500
10
2.1
(59.3)
2.3
(65.2)
115
cURus, cTÜVus, CE
2.3
(65.8)
2.5
(71.7)
Typ
Max
Unit
V
RMS
V
RMS
V
RMS
MΩ
ounces
(grams)
ounces
(grams)
°C
See Figs. 3 and 5. Do not operate coverter >100°C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
Notes
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
IN to OUT, IN to baseplate, OUT to baseplate
* Isolation test voltage, 1 minute or less.
Note:
Specifications are subject to change without notice.
48V Micro Family
Page 3 of 13
Rev 8.6
06/2017
vicorpower.com
800 927.9474
48V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS
2V
OUT
,
50W (e.g. V48C2C50BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
76.5
2.7
Typ
77.8
85
2.8
3.3
±0.02
28.8
28.8
Max
106
2.9
4.9
±0.2
25
35
35
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
25.3
17.5
3.3V
OUT
, 75W (e.g. V48C3V3C75BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
82.5
4.14
Typ
83.7
75
4.3
3
±0.02
26.2
26.2
Max
94
4.46
4.5
±0.2
22.7
31.8
31.8
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
22.9
15.9
3.3V
OUT
, 50W (e.g.V48C3V3C50BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
78
4.14
Typ
79.6
75
4.3
2.9
±0.02
17.5
17.5
Max
94
4.46
3.7
±0.2
15.15
20.6
20.6
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
15.5
10.6
5V
OUT
, 100W (e.g. V48C5C100BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
83
6.03
Typ
85
70
6.25
3.3
±0.02
23
23
Max
88
6.47
5
±0.3
20
26
26
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
20.4
14
5V
OUT
, 75W (e.g. V48C5C75BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
82
6.03
Typ
83
100
6.25
3
±0.02
17.3
17.3
Max
125
6.47
4.5
±0.2
15
19.5
19.5
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
15.3
10.5
48V Micro Family
Page 4 of 13
Rev 8.6
06/2017
vicorpower.com
800 927.9474
48V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
5V
OUT
, 50W (e.g. V48C5C50BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
83.5
6.03
Typ
84.5
85
6.25
1.6
±0.02
11.5
11.5
Max
106
6.47
2.4
±0.2
10
13
13
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
10.2
7
8V
OUT
, 100W (e.g. V48C8C100BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
86.5
9.36
Typ
87.7
121
9.7
3.6
±0.02
14.4
14.4
Max
152
10.1
4.5
±0.2
12.5
16.9
16.9
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
12.7
8.75
8V
OUT
, 150W (e.g. V48C8C150BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
86.5
9.36
Typ
87.8
138
9.7
3.6
±0.02
21.6
21.6
Max
173
10.1
4.6
±0.2
18.75
25.4
25.4
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
19.1
13.1
12V
OUT
, 150W (e.g. V48C12C150BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
88.0
13.7
Typ
89.1
170
14.3
3.5
±0.02
14.4
14.4
Max
212
14.9
5.3
±0.2
12.5
16.3
16.3
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
12.7
8.75
12V
OUT
, 75W (e.g. V48C12C75BL)
Parameter
Efficiency
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
87.0
13.7
Typ
88.3
160
14.3
2.6
±0.02
7.19
7.19
Max
200
14.9
3.8
±0.2
6.25
8.44
8.44
Unit
%
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
Now my program has several problems when using the dialog box mechanism. 1. The Chinese character encoding in the control list is messed up, such as "年" corresponds to E5B9B400... 2. Manually fill in ...
Anyone who has worked with GPRS transmission or modems, could you please share your experience on stable data transmission and power consumption control?...
Recently, I was debugging my MP3 design, and used SPI to read and write SD cards and send data to VS1003B. Because MP3 is very sensitive to data flow speed, I optimized the software SPI, and now it ca...
[i=s]This post was last edited by dontium on 2015-1-23 11:08[/i] Design with Operational Amplifiers and Analog Integrated Circuits (3rd Edition) is the English version of "Circuit Design Based on Oper...
I wrote a program on EVC and downloaded it to the terminal. When I run it, it prompts: Not a valid Windows CE application. What's going on? What can I do?...
When we travel in cities, we all find that electric vehicles have many advantages. As a means of transportation, they can also fulfill their mission well. Now, more and more residential communities...[Details]
The most significant feature of IPS panels is that both electrodes are located on the same surface, unlike other LCD panels, which have electrodes arranged on top and bottom surfaces in a three-dim...[Details]
Current Development Status of DVR Market
A DVR, or digital video recorder, uses a hard disk for recording, unlike traditional analog video recorders. It's often called a DVR because it's a com...[Details]
Introduction to the principles of speech recognition technology
Automatic speech recognition (ASR) technology aims to enable computers to understand human speech and extract the textual inform...[Details]
In mobile technology, sensors are the primary input for measured signals and form a component of a sensor system. They include sensitive and transducer elements connected to carriers and circuits. ...[Details]
Capable of providing precise and efficient thermal management for artificial intelligence computing power, intelligent sensing and autonomous driving systems
Shenzhen, ...[Details]
On August 20th, Tiantai Robotics Co., Ltd., along with strategic partners including Shandong Future Robotics Technology Co., Ltd., Shandong Future Data Technology Co., Ltd., and Gangzai Robotics Gr...[Details]
Since the beginning of this year, price wars have intensified, new models have been launched one after another, used cars with zero kilometers have become a hot topic, and the industry's internal c...[Details]
While the current industry consensus is that autonomous vehicles are robots and that their systems are managed using robotics-developed thinking, there are also cases where autonomous driving is ac...[Details]
Reflow soldering is one of the most commonly used methods in electronics manufacturing, allowing for the soldering of large numbers of components in a relatively short time. However, any experience...[Details]
Linear motor modules have become the "sweet spot" in various fields due to their advantages such as long stroke, fast speed, high precision, smooth operation and long life. Different models of line...[Details]
We often hear about the precautions for using pure electric vehicles in winter, and many owners even develop relevant strategies, such as adopting a "charge as you go" principle for their vehicles,...[Details]
Charging is an essential topic for electric vehicles. Batteries are a core component of new energy vehicles. So, what's the optimal charge level for electric vehicles? Based on current battery tech...[Details]
Electric vehicles are composed of three main components: electric motors, electric motors, and electric vehicles. Maintenance is much simpler than for gasoline-powered vehicles. Maintenance for ele...[Details]
Electric vehicles will revolutionize transportation, changing fuel consumption, carbon emissions, costs, maintenance, and driving habits. Currently, a major selling point for electric vehicles is t...[Details]