FM1001-9PD2AH

Description
DC-DC Regulated Power Supply Module, 1 Output, METAL, CASE M02, MODULE
CategoryPower/power management    The power supply circuit   
File Size147KB,4 Pages
ManufacturerBel Fuse
Download Datasheet Parametric View All

FM1001-9PD2AH Overview

DC-DC Regulated Power Supply Module, 1 Output, METAL, CASE M02, MODULE

FM1001-9PD2AH Parametric

Parameter NameAttribute value
Brand NamePower-One
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerBel Fuse
Parts packaging codeMODULE
package instruction,
Manufacturer packaging codeCASE M02
Reach Compliance Codecompliant
ECCN codeEAR99
Analog Integrated Circuits - Other TypesDC-DC REGULATED POWER SUPPLY MODULE
Maximum input voltage100 V
Minimum input voltage20 V
JESD-30 codeR-MXMA-X
JESD-609 codee0
Number of functions1
Output times1
Maximum operating temperature71 °C
Minimum operating temperature-40 °C
Maximum output voltage5.355 V
Minimum output voltage4.845 V
Nominal output voltage5.1 V
Package body materialMETAL
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
technologyHYBRID
Temperature levelOTHER
Terminal surfaceTIN LEAD
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Maximum time at peak reflow temperatureNOT SPECIFIED
Maximum total power output50 W
Fine-tuning/adjustable outputNO
Base Number Matches1
M Series
50 Watt DC-DC Converters
Wide input voltage from 8...372 V DC
1, 2 or 3 isolated outputs up to 48 V DC
4 kV AC I/O electric strength test voltage
LGA
• Rugged electrical and mechanical design
• Outputs individually controlled with excellent
dynamic properties
• Operating ambient temperature range
–40...71°C
Selection chart
Output 1
Output 2
U
o nom
I
o nom
U
o nom
I
o nom
[V DC] [A] [V DC] [A]
5.1
8
-
-
12
4
-
-
15
3.4
-
-
24
2
-
-
48
1
-
-
12
2
12
2
15
1.7
15
1.7
5.1
5
12
0.7
5.1
5
15
0.6
Output 1
Output 2
U
o nom
I
o nom
U
o nom
I
o nom
[V DC] [A] [V DC] [A]
5.1
8
-
-
12
4
-
-
15
3.4
-
-
24
2
-
-
48
1
-
-
12
2
12
2
15
1.7
15
1.7
5.1
5
12
0.7
5.1
5
15
0.6
Output 3
U
o nom
I
o nom
[V DC] [A]
-
-
-
-
-
-
-
-
-
-
-
-
-
-
12
0.7
15
0.6
Type
Input voltage
8...35 V DC
AM 1001-7R
AM 1301-7R
AM 1501-7R
AM 1601-7R
AM 1901-7R
AM 2320-7
AM 2540-7
AM 3020-7
AM 3040-7
Type
Type
Input voltage Input voltage
14...70 V DC 20...100 V DC
BM 1001-7R FM 1001-7R
BM 1301-7R FM 1301-7R
BM 1501-7R FM 1501-7R
BM 1601-7R FM 1601-7R
BM 1901-7R FM 1901-7R
BM 2320-7
FM 2320-7
BM 2540-7
FM 2540-7
BM 3020-7
FM 3020-7
BM 3040-7
FM 3040-7
Options
-9, P, D, V, A, H, F
-9, P, D, A, H, F
-9, P, D, A, H, F
-9, P, D, A, H, F
-9, P, D, A, H, F
-9, P, D, A, H, F
-9, P, D, A, H, F
-9, P, D, V, A, H, F
-9, P, D, V, A, H, F
Options
Output 3
Type
Type
Type
U
o nom
I
o nom
Input voltage Input voltage Input voltage
[V DC] [A] 28...140 V DC 44...220 V DC 88...372 V DC
-
-
CM 1001-7R DM 1001-7R LM 1001-7R
-
-
CM 1301-7R DM 1301-7R LM 1301-7R
-
-
CM 1501-7R DM 1501-7R LM 1501-7R
-
-
CM 1601-7R DM 1601-7R LM 1601-7R
-
-
CM 1901-7R DM 1901-7R LM 1901-7R
-
-
CM 2320-7
DM 2320-7
LM 2320-7
-
-
CM 2540-7
DM 2540-7
LM 2540-7
12
0.7
CM 3020-7
DM 3020-7
LM 3020-7
15
0.6
CM 3040-7
DM 3040-7
LM 3040-7
-9, E, P, D, V, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, A, H, F
-9, E, P, D, V, A, H, F
-9, E, P, D, V, A, H, F
CM, DM and LM types available as CMZ, DMZ and LMZ class II equipment
2/12.2000
www.power-one.com
1
PCB Design Experience (4) - Considerations for Wiring
Source: Software and Hardware Integration Network 1. Routing priority Critical signal lines should be prioritized: power supply, analog small signals, high-speed signals, clock signals, and synchroniz...
ohahaha PCB Design
Labview_Serial Port Application Explanation
Labview_Serial Port Application Explanation...
安_然 Test/Measurement
Research on integrated application of building automation remote monitoring system
Abstract The building automation remote monitoring system integrating Internet/Intranet and control network is a research hotspot in the current intelligent building field. This paper first analyzes t...
frozenviolet Industrial Control Electronics
I'm asking a question about msp430 interrupts
I want to use the 430 io interrupt to receive the infrared remote control signal. When the 430 io is set as an interrupt port, can it be used as an input signal? Otherwise, how can I connect it?...
qianguang1989 Microcontroller MCU
Introduction to C language design
Introduction to C language design...
Smithlee89 MCU
Divisor Latch Access Bit
Divisor Latch Access Bit, what is this bit and what is its use? It is used when setting up the UART. I can't understand why it is like this when looking at the program: U0LCR = 0x83; /* 8 bits, no Par...
yjqlife2008 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2062  1250  1201  341  1981  42  26  25  7  40 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号