EEWORLDEEWORLDEEWORLD

Part Number

Search

177-710-2-9GP4K7-24LAN

Description
Interconnection Device
CategoryThe connector    The connector   
File Size436KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Environmental Compliance
Download Datasheet Parametric View All

177-710-2-9GP4K7-24LAN Overview

Interconnection Device

177-710-2-9GP4K7-24LAN Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompli
Connector typeINTERCONNECTION DEVICE
Base Number Matches1
MWDM Micro-D Shielded Cable Assemblies
Single-Ended or Double-Ended–These
easy-to-order cable
assemblies eliminate the need for expensive assembly
labor. 100% tested and ready for use.
Now With Twisted Pairs–No
need to create a procurement
specification for Micro-D cables with twisted pairs. Glenair
177-740 cables are furnished with a full complement of
white/blue twisted pair wires.
Integral Shield Termination–The
connector shell has a
platform to accept Band-It shield termination bands. The
cable shield braid is attached directly to the connector.
Save Labor, Reduce Weight and Improve EMI Shielding with
Glenair’s Micro-D Shielded Cable Assemblies
Aerospace electronics systems require higher and higher levels of protection from radiated emissions. Glenair’s fully
shielded Micro-D cable assemblies meet this need. The cable shield is attached directly onto the one-piece connector
shell and secured with a stainless steel
BAND-IT
® clamp. These pre-wired, 100% tested assemblies meet the
requirements of MIL-DTL-83513. An optional ground spring on the pin connector assures low shell-to-shell resistance.
Available with a variety of wire types and shields, Micro-D shielded assemblies can be ordered in any length, either
single-ended or “back-to-back”.
Ground Spring and EMI Shielding Effectiveness
– A gold-plated
stainless steel ground spring on the pin connector mating face offers
substantial improvement in EMI protection. The graphs compare
identical connectors tested with and without ground springs.
EMI Performance with Ground Spring
SHIELDING EFFECTIVENESS (DB)
SHIELDING EFFECTIVENESS (DB)
100
90
80
70
60
50
40
30
20
10
0
1.00E+03
100
90
80
70
60
50
40
30
20
10
0
1.00E+03
EMI Performance without Ground Spring
1.00E+04
1.00E+05
1.00E+06
1.00E+07
1.00E+08
1.00E+09
1.00E+04
1.00E+05
1.00E+06
1.00E+07
1.00E+08
1.00E+09
FREQUENCY (Hz)
FREQUENCY (Hz)
© 2006 Glenair, Inc.
CAGE Code 06324/0CA77
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
B-8
E-Mail: sales@glenair.com
I would like to ask CE experts, where are the window messages (messages sent by other processes) received? Why is there no WndProc()?
I would like to ask CE experts, where are the window messages (messages sent by other processes) received? Why is there no WndProc()? It's urgent!...
lijia687 Embedded System
Practical questions about Windows 2000/XP WDM device driver development
The examples in Wu Anhe's "Windows2000/XP WDM Device Driver Development" are based on win2000/DS2.6/win2k ddk. I am using win xp, DS2.6, and after installing xp sp1 ddk, I can still compile and genera...
wonitaluck Embedded System
Switching power supply use
How can I use an existing switching power supply when not in a lab? What should I use to connect the live and neutral wires at the input? Can I use the existing plugs to modify it? I need your advice,...
lusss Test/Measurement
LED transparent screen signal transmission method
LED transparent screens have been widely used in leisure and civilization squares, wealthy business bases, commercial streets, railway stations, subways, shopping malls and other places. Due to the di...
jucaiyuan008 Industrial Control Electronics
Multiple CAN nodes cannot communicate
Now I have three boards, two BeagleBone boards and one TMS320F2812 self-made board. I found that these three boards can communicate with each other when connected in pairs, but they cannot communicate...
zmicky DSP and ARM Processors
HOLTEK large table reading application and source code
hOLTEK large table reading, this example uses HT48R30A...
rain Analog electronics

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1633  1908  1737  213  1033  33  39  35  5  21 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号