Off-line systems with PFC front ends, industrial and process control, distributed power,
medical, ATE, communications, defense and aerospace.
For details on proper operation please refer to the:
Design Guide & Applications Manual for Maxi, Mini, Micro Family.
Absolute Maximum Ratings
Product Overview
These DC-DC converter modules use advanced
power processing, control and packaging
technologies to provide the performance,
flexibility, reliability and cost effectiveness of a
mature power component.
High frequency ZCS/ZVS switching provides
high power density with low noise and
high efficiency.
Part Numbering
e.g. V375A12T600BL2
375A
Product Grade Temperatures (°C)
Grade
Operating
Storage
E
= - 10 to +100 - 20 to +125
C
= - 20 to +100 - 40 to +125
T
= - 40 to +100 - 40 to +125
H
= - 40 to +100 - 55 to +125
M
= - 55 to +100 - 65 to +125
B
Output Power
P
OUT
160W
200W, 264W
300W, 400W
300W, 400W
400W, 600W
400W, 600W
400W, 600W
400W, 600W
600W
400W, 500W, 600W
400W, 600W
600W
Pin Style
Finish
Blank:
Short
Tin/Lead
L:
Long
Tin/Lead
S:
Short ModuMate
Gold
N:
Long ModuMate
Gold
F:
Short RoHS
Gold
G:
Long RoHS
Gold
K:
Extra Long RoHS
Gold
Baseplate
Blank:
Slotted
2:
Threaded
3:
Through-hole
Product Type
V
= Standard
S
= Enhanced
efficiency
(avail.
≤12
V
OUT
only)
Output Voltage
2
= 2V
3V3
= 3.3V
5
= 5V
8
= 8V
12
= 12V
15
= 15V
24
= 24V
28
= 28V
32
= 32V
36
= 36V
48
= 48V
54
= 54V
V
OUT
2V
3.3V
5V
8V
12V
15V
24V
28V
32V
36V
48V
54V
375V Maxi Family
Page 1 of 15
Rev 10.0
10/2017
375V Input
Module Family Electrical Characteristics
Electrical characteristics apply over the full operating range of input voltage, output load (resistive) and baseplate temperature, unless otherwise specified.
All temperatures refer to the operating temperature at the center of the baseplate.
MODULE INPUT SPECIFICATIONS
Parameter
Operating input voltage
Input surge withstand
Undervoltage turn-on
Undervoltage turn-off
Overvoltage turn-off/on
Disabled input current
204.7
429.2
242.5
212.2
446.3
467.5
1.1
Min
250
Typ
375
Max
425
500
247.5
Unit
V
DC
V
DC
V
DC
V
DC
V
DC
mA
PC pin low
<100ms
Notes
MODULE OUTPUT SPECIFICATIONS
Parameter
Output voltage setpoint
Line regulation
Temperature regulation
Power sharing accuracy
Programming range
10
±0.02
±0.002
±2
Min
Typ
Max
1
±0.2
±0.005
±5
110
Unit
%
%
% / °C
%
%
Notes
Of nominal output voltage. Nominal input; full load; 25°C
Low line to high line; full load
Over operating temperature range
10 to 100% of full load
Of nominal output voltage. For trimming below 90%
of nominal, a minimum load of 10% of maximum
rated power may be required.
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
Externally applied
+OUT to –OUT, +Sense to –OUT — Absolute Maximum Ratings
2V
3.3V
5V
8V
12V
15V
24V
28V
32V
36V
48V
54V
-0.5 to 3.1
-0.5 to 4.7
-0.5 to 7.0
-0.5 to 10.9
-0.5 to 16.1
-0.5 to 20.0
-0.5 to 31.7
-0.5 to 36.9
-0.5 to 41.9
-0.5 to 47.1
-0.5 to 62.9
-0.5 to 70.2
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
V
DC
Note:
The permissible load current must never be exceeded during normal, abnormal or test conditions. For additional output related application
information, please refer to output connections on page 10.
THERMAL RESISTANCE AND CAPACITY
Parameter
Baseplate to sink; flat, greased surface
Baseplate to sink; thermal pad (P/N 20263)
Baseplate to ambient
Baseplate to ambient; 1000LFM
Thermal capacity
Min
Typ
0.08
0.07
4.9
1.1
165
Max
Unit
°C/Watt
°C/Watt
°C/Watt
°C/Watt
Watt-sec/°C
375V Maxi Family
Page 2 of 15
Rev 10.0
10/2017
375V Input
Module Family Electrical Characteristics (Cont.)
MODULE CONTROL SPECIFICATIONS
Parameter
Min
Typ
Max
Unit
Notes
Primary Side (PC = Primary Control; PR = Parallel)
PC bias voltage
current limit
PC module disable
PC module enable delay
PC module alarm
PC resistance
PR emitter amplitude
PR emitter current
PR receiver impedance
PR receiver threshold
PR drive capability
Secondary Side (SC = Secondary Control)
SC bandgap voltage
SC resistance
SC capacitance
SC module alarm
1.21
990
1.23
1000
0.033
0
1.25
1010
V
DC
Ω
µF
V
DC
With open trim; referenced to –Sense. See Fig. 7
Referenced to –Sense
0.9
5.7
150
375
2.4
500
2.5
625
2.6
12
1.0
5.9
5.50
1.5
2.3
5.75
2.1
2.6
4
6.00
3.0
2.9
7
0.5
1.1
6.1
V
DC
mA
V
DC
ms
Vavg
MΩ
Volts
mA
Ω
Volts
modules
25°C
Minimum pulse width: 20ns
Without PR buffer amplifier
UV, OV, OT, module fault. See Figs. 3 and 5
See Fig. 3, converter off or fault mode
PR load >30Ω, <30pF
PC current = 1.0mA
PC voltage = 5.5V
During normal operation
Switch must be able to sink
≥4mA.
See Fig. 2
MODULE GENERAL SPECIFICATIONS
Parameter
Remote sense (total drop)
Isolation test voltage (IN to OUT)*
Isolation test voltage (IN to base)*
Isolation test voltage (OUT to base)*
Isolation resistance
Weight (E, C, T grade)
Weight (H, M grade)
6.5
(184.3)
7.4
(209.3)
100
3000
1500
500
10
7.3
(207.5)
8.2
(232.5)
115
cURus, cTÜVus, CE
8.1
(230.7)
9.0
(255.7)
Min
Typ
Max
0.5
Unit
V
DC
V
RMS
V
RMS
V
RMS
MΩ
ounces
(grams)
ounces
(grams)
°C
See Figs. 3 and 5. Do not operate coverter >100°C.
UL60950-1, EN60950-1, CSA60950-1, IEC60950-1.
With appropriate fuse in series with the +Input
Notes
0.25V per leg (sense leads must be connected to
respective, output terminals)
Complies with reinforced insulation requirements
Complies with basic insulation requirements
Complies with operational insulation requirements
IN to OUT, IN to baseplate, OUT to baseplate
Temperature limiting
Agency approvals
* Isolation test voltage, 1 minute or less.
Note:
Specifications are subject to change without notice.
375V Maxi Family
Page 3 of 15
Rev 10.0
10/2017
375V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS
2V
OUT
, 160W (e.g. S375A2C160BL, V375A2C160BL)
Parameter
Efficiency
S375A2C160BL (enhanced efficiency)
V375A2C160BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
76.0
72.0
2.7
Typ
80.0
73.7
200
2.8
8.4
±0.02
92
92
Max
Unit
%
250
2.9
11
±0.2
80
108
108
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
81.6
56
3.3V
OUT
, 264W (e.g. S375A3V3C264BL, V375A3V3C264BL)
Parameter
Efficiency
S375A3V3C264BL (enhanced efficiency)
V375A3V3C264BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
83.0
80.0
4.14
Typ
86.0
81.0
120
4.3
4.9
±0.02
92
92
Max
Unit
%
150
4.46
7.8
±0.2
80
104
104
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
81.6
56
3.3V
OUT
, 200W (e.g. S375A3V3C200BL, V375A3V3C200BL)
Parameter
Efficiency
S375A3V3C200BL (enhanced efficiency)
V375A3V3C200BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
82.0
78.0
4.14
Typ
86.0
78.9
60
4.3
7.9
±0.02
69.7
69.7
Max
Unit
%
75
4.46
9.1
±0.2
60.6
81.9
81.9
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
61.8
42.4
5V
OUT
, 400W (e.g. S375A5C400BL, V375A5C400BL)
Parameter
Efficiency
S375A5C400BL (enhanced efficiency)
V375A5C400BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
84.0
80.0
6.26
Typ
86.0
83.0
120
6.49
6.6
±0.02
92
97
Max
Unit
%
150
6.72
9
±0.2
80
108
108
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
81.6
56
375V Maxi Family
Page 4 of 15
Rev 10.0
10/2017
375V Input
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
5V
OUT
, 300W (e.g. S375A5C300BL, V375A5C300BL)
Parameter
Efficiency
S375A5C300BL (enhanced efficiency)
V375A5C300BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
84.0
82.0
6.03
Typ
87.0
83.3
80
6.25
8.8
±0.02
69
69
Max
Unit
%
100
6.47
10.2
±0.2
60
81
81
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
61.2
42
8V
OUT
, 400W (e.g. S375A8C400BL, V375A8C400BL)
Parameter
Efficiency
S375A8C400BL (enhanced efficiency)
V375A8C400BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
84.0
82.5
9.55
Typ
87.0
83.6
288
9.9
17.9
±0.02
57.5
57.5
Max
Unit
%
360
10.3
19
±0.2
50
67.5
67.5
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
51
35
8V
OUT
, 300W (e.g. S375A8C300BL, V375A8C300BL)
Parameter
Efficiency
S375A8C300BL (enhanced efficiency)
V375A8C300BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Output Current
Current limit
Short circuit current
Min
85.0
82
9.36
Typ
87.0
83.1
220
9.7
9.3
±0.02
43.1
43.1
Max
Unit
%
275
10.1
10.8
±0.2
37.5
50.7
50.7
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
No load
No load to full load; nominal input
Output voltage 95% of nominal
Output voltage <250mV
0
38.2
26.2
12V
OUT
, 600W (e.g. S375A12C600BL, V375A12C600BL)
Parameter
Efficiency
S375A12C600BL(enhanced efficiency)
V375A12C600BL (standard efficiency)
Ripple and noise
Output OVP setpoint
Dissipation, standby
Load regulation
Load current
Current limit
Short circuit current
Min
86.0
86.0
13.7
Typ
89.0
87.1
320
14.3
8.7
±0.02
57.5
57.5
Max
Unit
%
400
14.9
13
±0.2
50
67.5
67.5
mV
Volts
Watts
%
Amps
Amps
Amps
Notes
Nominal input; full load; 25°C
p-p; Nominal input; full load; 20MHz bandwidth
25°C; recycle input voltage or PC to restart (>100ms off)
In order to make the MCU enter interrupt, a sentence __bis_SR_register(LPM4_bits + GIE); // Enter LPM4 w/interrupt must be added in the main function. LPM4_bits can be changed according to actual cond...
[i=s] This post was last edited by dontium on 2015-1-23 11:10 [/i] I got this book and first looked at the price. It's not a thick book, but the price is 58 yuan, which seems a bit expensive:surrender...
Before talking about the protagonist, let me explain the background. In 1968, the United States established the ALOHA network, which required fixed base stations. Each node in the network must be dire...
[b][color=#5E7384]This content is originally created by EEWORLD forum user [size=3]dcexpert[/size]. If you want to reprint or use it for commercial purposes, you must obtain the author's consent and i...
This is my first time writing a watchdog program and I have the following questionsA. The following program writing method is considered to be clearing the watchdog in the main program! If not, how to...
A single-chip microcomputer is also called a single-chip microcontroller. It is not a chip that completes a certain logical function, but a computer system integrated into one chip. In general, a c...[Details]
1. Overview
Will passive devices
produce nonlinear intermodulation distortion? The answer is yes! Although there is no systematic theoretical analysis, it has been found in engineerin...[Details]
0. Introduction
In daily life, we often see some special-purpose vehicles. When these vehicles pass through intersections, they often obtain the right of way at intersections by temporarily op...[Details]
Abstract: In order to generate a stable excitation signal, the design of a digital frequency synthesizer is implemented on FPGA using Verilog hardware language. The design includes accumulator, wav...[Details]
In public places such as schools, government agencies, factories and mines, as well as public corridors in residential areas, the phenomenon of long-burning lights is very common, which causes a h...[Details]
In recent years, lighting has become an important area that countries around the world are targeting to promote energy conservation and environmental protection. According to statistics, about 20% ...[Details]
This controller uses PIC16C54 single-chip microcomputer as the controller, and it is very easy to use: just connect a telephone line to the loudspeaker through the controller, and you can rem...[Details]
Abstract: The output of high-range acceleration sensor is less than 10 mV under the excitation of small signal. The noise of traditional test system may cover such small voltage signal, so that hig...[Details]
Since the late 1990s, with the demand for higher system efficiency and lower power consumption, the technological update of telecommunications and data communication equipment has promoted the deve...[Details]
Fruit planting is an important part of China's agricultural development, and fruit tree pest control operations are becoming more and more important. At present, the overall level of pesticide applica...[Details]
1 Overview
In the field of traditional lighting, the concepts and definitions of lamps and lamps are clear. Lamps and lamps have their own applicable product standards, supporting technical st...[Details]
LED is now known as the fourth generation of light sources. High-power LED has many advantages over traditional light sources in outdoor lighting.
1 LED lamps have high light efficiency
C...[Details]
Rated capacity refers to the maximum output power of the UPS (the product of voltage V and current A).
Usually, the UPS power supplies sold on the market are marked with "W" (watt) for smaller...[Details]
This article focuses on closing the feedback loop of an isolated power supply using a TL431 shunt regulator. The article discusses a method to extend the bandwidth of the power supply control loop ...[Details]
introduction
The core features of mobile value-added service products are mobility, immediacy and personalization. Mobile value-added services are a new service mode that is rapidly developing...[Details]