EEWORLDEEWORLDEEWORLD

Part Number

Search

BC125C224MZB9AA3

Description
Ceramic Capacitor, Multilayer, Ceramic, 50V, 20% +Tol, 20% -Tol, X7R, 15% TC, 0.22uF, Surface Mount, 1812, CHIP
CategoryPassive components    capacitor   
File Size141KB,8 Pages
ManufacturerAVX
Download Datasheet Parametric View All

BC125C224MZB9AA3 Overview

Ceramic Capacitor, Multilayer, Ceramic, 50V, 20% +Tol, 20% -Tol, X7R, 15% TC, 0.22uF, Surface Mount, 1812, CHIP

BC125C224MZB9AA3 Parametric

Parameter NameAttribute value
Objectid7110185256
package instruction, 1812
Reach Compliance Codecompliant
ECCN codeEAR99
YTEOL0
capacitance0.22 µF
Capacitor typeCERAMIC CAPACITOR
dielectric materialsCERAMIC
high1.27 mm
JESD-609 codee0
length4.5 mm
Installation featuresSURFACE MOUNT
multi-layerYes
negative tolerance20%
Number of terminals2
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Package formSMT
method of packingBulk
positive tolerance20%
Rated (DC) voltage (URdc)50 V
size code1812
surface mountYES
Temperature characteristic codeX7R
Temperature Coefficient15% ppm/°C
Terminal surfaceTin/Lead (Sn/Pb)
Terminal shapeWRAPAROUND
width3.2 mm
COTS Plus - BC Series
General Specifications
GENERAL DESCRIPTION
Extended range MLCCs for avionic, defense, and space applications have
been available from AVX for many years, typically to customer specification
control documents. The COTS PLUS - BC series now consolidates the main
test options into standard catalog offerings, eliminating the need to generate
custom specifications for each application. Key test options from MIL-PRF-
55681 are applied to BME and PME devices in NP0 and X7R temperature
characteristic dielectrics.
PRODUCT ADVANTAGES
• Higher CV capability than standard PME
• BME and PME technology
• Voltage Range up to 500V
APPLICATIONS
Defense/Aerospace
• Extended Range MLCC for all Applications
• Low weight/payload, small footprint
• Low Voltage Ratings to Maximize Capacitance for High Speed Decoupling
HOW TO ORDER
BC
Series
03
Size
02 = 0402
03 = 0603
05 = 0805
06 = 1206
10 = 1210
12 = 1812
13 = 1825
5
C
102
Capacitance
Code (In pF)
2 Sig. Digits +
Number of
Zeros
K*
Z
T
9
AA
1
Extened Test Level
0 = Not Applicable
1 = DPA IAW EIA-469
2 = 85/85 @ RV for 96 hours
3 = DPA and 85/85 @ RV
Dielectric
Voltage
Z = 10V A = C0G (NP0)
Y = 16V C = X7R
3 = 25V
5 = 50V
1 = 100V
2 = 200V
V = 250V
7 = 500V
Capacitance
Failure Rate
Termination
Tolerance
Z = COTS Plus T = 100% TN
B = ±.10 pF
B = Tin/Lead
C = ±.25 pF
(5% min Lead)
D = ±.50 pF
J = Tin/Lead (60/40)
F = ±1% (≥ 10 pF)
G = ±2% (≥ 10 pF)
J = ±5%
K = ±10%
M = ±20%
* B, C & D tolerance for ≤10 pF values.
Packaging
Base Group A Test Level
1 = 7" T&R
AA = Group A per MIL-PRF-55681
3 = 13" T&R
SA = Group A per MIL-PRF-55681
6 = Waffle Pack
with SLDC
(SLDC = Single Lot Date Code)
9 = Bulk
CONFORMANCE TEST LEVELS
Base Group A Test Options
Voltage Conditioning IAW MIL-PRF-55681
Elevated IR Sample
Visual and Mechanical Inspection
Solderability
Single Lot Date Code (SLDC)
Group A Data Summary
AA
SA
Extended Test Options
Not Applicable
DPA IAW EIA-469
85°C/85% RH @ Rated Voltage / 96 Hrs
DPA and 85/85 @ Rated Voltage
Code
0
1
2
3
081516
1
How to get the maximum power for charging the battery
How to make the power supply provide maximum power for battery charging From Texas Instrumentseeworldpostqq...
莫妮卡 Analogue and Mixed Signal
How can I view the topics I replied to?
I would like to ask everyone: Is there a function to view "my replies" in the forum? I have been looking for a long time but can't find it......
swfc_qinmm Suggestions & Announcements
A novice asking for advice. In addition to the traditional PWM input capture method to measure PWM period and duty cycle, are there other ways to achieve this?
For example, the signal input pin external interrupt exit (double edge), open timer TIM3, and record the different TIM3->cnt values when different edge interrupts occur. I wonder if this is possible? ...
wanglingdeemo stm32/stm8
What is a recording digital pressure gauge? In what fields is it used?
The recording type digital pressure gauge is also called the recording type pressure gauge or storage type pressure gauge. The recording type digital pressure gauge has a built-in high-precision press...
上海铭控 Sensor
Basic learning of programming
JavaSE_zsy...
向南1 Download Centre
How to write the timer capture timing and timer capture count code of M4? Please give me some advice
How to write the timer capture timing and timer capture count code of M4? Please give me some advice...
拓磊 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1530  657  1768  280  11  31  14  36  6  1 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号