EEWORLDEEWORLDEEWORLD

Part Number

Search

232-103-H7Z18-98PA-02

Description
Circular Connector Adapter, 3 Contact(s), Stainless Steel, Male-Female
CategoryThe connector    The connector   
File Size435KB,1 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

232-103-H7Z18-98PA-02 Overview

Circular Connector Adapter, 3 Contact(s), Stainless Steel, Male-Female

232-103-H7Z18-98PA-02 Parametric

Parameter NameAttribute value
Reach Compliance Codecompliant
Other featuresSTANDARD: MIL-DTL-38999
Connector typeCIRCULAR CONNECTOR ADAPTER
Contact point genderMALE-FEMALE
Coupling typeBAYONET
DIN complianceNO
empty shellNO
Filter functionNO
IEC complianceNO
MIL complianceYES
Manufacturer's serial number232-103-H7
Mixed contactsNO
Installation typePANEL
OptionsHERMETIC
Shell materialSTAINLESS STEEL
Total number of contacts3
Base Number Matches1
232-103-H7
Jam Nut Mount Hermetic Bulkhead Feed-Thru
MIL-DTL-38999 Series II Type
Connector Series
232
-
D38999 Series II Type
Shell Style
H7
- Jam Nut Mount
Shell Size
08
10
12
14
16
18
20
22
24
Insert Arrangement
Per MIL-DTL-38999 Series II
MIL-STD-1560
Alternate Key
Position
A, B, C, D
(N = Normal)
1.69 Max
.915 REF
B TYP
232
-
103
-
H7 Z1 10
-
35 P N
-
01
Connector Type
103
-
Hermetic Bulkhead
Feed-Thru
Connector Material and Finish
FT
- Carbon Steel, Fused Tin
Z1
- CRES, Passivated
ZL
- CRES, Nickel Finish
A Thread
Hole for .032 DIA Safety
Wire, 3 Equally Spaced
.125
.150 Max
Contact Termination
P
- Pin on Jam Nut Side
S
- Socket on Jam Nut Side
Panel Accom.
E Dia
Panel Accomodation
01
- .0625″ (Min) .125″ (Max)
02
- .0625″ (Min) .250″ (Max)
03
- .0625″ (Min) .500″ (Max)
F
Recommended Panel Cut-Out
TABLE I: CONNECTOR DIMENSIONS
SHELL
SIZE
08
10
12
14
16
18
20
22
24
A THREAD
CLASS 2A
.875-20 UNEF
1.000-20 UNEF
1.125-18 UNEF
1.250-18 UNEF
1.375-18 UNEF
1.500-18 UNEF
1.625-18 UNEF
1.750-18 UNS
1.875-16 UN
B DIA
MAX
.474(12.0)
.591(15.0)
.751(19.1)
.876(22.3)
1.001(25.4)
1.126(28.6)
1.251(31.8)
1.376(35.0)
1.501(38.1)
C
HEX
1.062(27.0)
1.188(30.2)
1.312(33.3)
1.438(36.5)
1.562(39.7)
1.688(42.9)
1.812(46.0)
2.000(50.8)
2.125(54.0)
D
FLATS
1.250(31.8)
1.375(34.9)
1.500(38.1)
1.625(41.3)
1.781(45.2)
1.890(48.0)
2.016(51.2)
2.140(54.4)
2.265(57.5)
E DIA
±.005(0.1)
.885(22.5)
1.010(25.7)
1.135(28.8)
1.260(32.0)
1.385(35.2)
1.510(38.4)
1.635(41.5)
1.760(44.7)
1.885(47.9)
F +.000-.005
(0-0.1)
.830(21.1)
.955(24.3)
1.085(27.6)
1.210(30.7)
1.335(33.9)
1.460(37.1)
1.585(40.3)
1.710(43.4)
1.835(46.6)
C
D
Insert Arrangement per
MIL-DTL-38999, Series Il
MIL-STD-1560
APPLICATION NOTES
1.
2.
3.
Power to a given contact on one end will result in power to contact directly
opposite, regardless of identification letter.
Hermeticity = less than 1 x 10
-4
cc/sec at one atmosphere. Not for use in liquid
atmosphere.
Material/finish:
Shell, nut – CRES/passivated, carbon steel/fused tin or CRES/nickel per QQ-N-290.
4.
Contacts – Gold Plated. Pin: alloy 52; Skt.: copper alloy
Insulator – fused vitreous glass/N.A.
Seals – fluorosilicone rubber/N.A.
Metric dimensions (mm) are indicated in parentheses.
© 2008 Glenair, Inc.
www.glenair.com
CAGE CODE 06324
Printed in U.S.A.
E-Mail: sales@glenair.com
GLENAIR, INC.
1211 AIR WAY
GLENDALE, CA 91201-2497
818-247-6000
FAX 818-500-9912
E-7
Bulkhead
Feed-Thrus
E
How to overcome the load-pull measurement challenges of 5G mmWave? (Part 1)
[p=25, null, left][color=rgb(51, 51, 51)][font=微软雅黑]The fifth generation of mobile communications represents the next evolutionary stage in wireless communications. With an emphasis on wireless connec...
alan000345 RF/Wirelessly
Find a self-locking relay switch circuit (using D flip-flop)
[color=#252525][size=14px]You need to use a button, a D flip-flop, a relay and a peripheral circuit to design a switch with a self-locking function. Press the button once and the relay will close. Pre...
dinghao1 Analog electronics
pid control
How to use PID to control brushed DC motor?...
啦啦啦嗯 Power technology
OCL quasi-complementary output circuit application analysis
What is the AC path from the output of the bipolar amplifier composed of T3 and T4 in the above circuit, that is, the AC signal at collector point B to the base of T6 and T8?...
小盼abc Analog electronics
How to set public variables when calling ASM functions using KEIL C
When calling an ASM function with KEIL C, I don't know how to set public variables, that is, how to reference variables shared with the C program in the assembly program. Please give me some advice, t...
zhangjun1960 Microcontroller MCU
Urgent question: About timer_A
I use the timer_A of MSP430F149 to generate PWM wave to drive the stepper motor. When I set the output PWM wave frequency to 4KHZ, it freezes, but when I set it to other frequencies, it can run normal...
einsye Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 620  918  466  1532  939  13  19  10  31  25 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号