805-003-22Z118-204HB

Description
Circular Connector, 42 Contact(s), Stainless Steel, Female, Crimp Terminal, Receptacle,
CategoryThe connector    The connector   
File Size2MB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

805-003-22Z118-204HB Overview

Circular Connector, 42 Contact(s), Stainless Steel, Female, Crimp Terminal, Receptacle,

805-003-22Z118-204HB Parametric

Parameter NameAttribute value
Objectid7093175382
Reach Compliance Codecompliant
ECCN codeEAR99
YTEOL8
Other featuresSTANDARD: MIL-DTL-38999
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeMIL SERIES CONNECTOR
Contact point genderFEMALE
Number of contacts40,2
Contact size23,16
Coupling typeTHREADED
DIN complianceNO
rotation75
other instructionsSQUARE FLANGE RECEPTACLE
empty shellNO
Environmental characteristicsCORROSION RESISTANT/ENVIRONMENT RESISTANT
Filter functionNO
IEC complianceNO
MIL complianceNO
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsYES
Installation typeCABLE AND PANEL
Maximum operating temperature175 °C
Minimum operating temperature-65 °C
OptionsGENERAL PURPOSE
polarizationB
Shell materialSTAINLESS STEEL
Housing size18
Termination typeCRIMP
Total number of contacts42
Unique insertion number18-204
805-003 and 805-004 Ordering Information
Three Shell Mounting Options:
Jam
nut with O-ring for rear panel mounting,
square flange for front or rear panel
mounting, or in-line receptacles for
free-hanging cables.
Gold-Plated Crimp Contacts are held in
place with beryllium copper retention
clips. Contacts are removable.
How To Order
Sample Part Number
Series (See Table I)
Two Shell Styles: Choose integral band
platform for direct attachment of a cable
shield. Install a boot, or overmold a boot
over the band platform. An accessory
thread is available for attaching strain
reliefs and backshells.
805-004
805-003
= Receptacle with Banding Platform
805-004
= Receptacle with Accessory Thread
-01
= In-line
-02
= Square Flange Front or Rear Mount
-12
= Square Flange Rear Mount Non-Locking Clinch Nuts
-22
= Square Flange Rear Mount Locking Clinch Nuts
-07
= Jam Nut for Rear Panel Mounting
C
= Aluminum / Black Anodize (Non-Conductive); RoHS Compliant
M
= Aluminum / Electroless Nickel; RoHS Compliant
MT
= Aluminum / Nickel-PTFE RoHS Compliant
NF
= Aluminum / Cadmium with Olive Drab Chromate
ZNU
= Aluminum / Zinc-Nickel with Black Chromate
Z1
= Stainless Steel / Passivated; RoHS Compliant
ZB
= Stainless Steel / Olive Drab Chromate over Cadmium
ZC
= Stainless Steel / Zinc Cobalt Alloy/Black Chromate
-02
NF
9-10
P
A
Shell Style (See Table II)
Shell Material and Finish
Shell Size - Insert
Arrangement
Contact Type
Shell Key Positions
(See Table III)
See Contact Arrangements Page H-2
With contacts
P
= Pin
S
= Socket
A
= Normal
Without contacts
A
= Pin Connector, less contacts
B
= Socket Connector, less contacts
With 30 AWG Crimp Barrel
G
= #23 Pin
H
= #23 Socket
F
= Pos. F
B
= Pos. B
C
= Pos. C
D
= Pos. D
E
= Pos. E
Table I: Series
Table II: Shell Style
805-003
Receptacle with Banding
Platform
805-004
Receptacle with Accessory
Thread
-01
In-line Receptacle
-02, -12, -22
Square Flange
-07
Jam Nut
Dimensions in Inches (millimeters) are subject to change without notice.
© 2014 Glenair, Inc.
Series 80 Mighty Mouse
U.S. CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC.
1211 AIR WAY
GLENDALE, CA 91201-2497
818-247-6000
FAX 818-500-9912
www.glenair.com
H-13
E-Mail: sales@glenair.com
Series 805
Series 805 Mighty Mouse
Triple-Start ACME Thread Receptacle
H
Analog interview questions (purely technical, about op-amp)
1. Compare three structures: a. 2-stage op-amp (active load, class-A output stage); b. telescopic op-amp; 3. folded-cascode op-amp. What are the advantages and disadvantages of each of the three? 2. W...
banana Analog electronics
Problems with using nfs server
I bought a linux development board, learned how to use nfs server. The server has been built, and now it needs to be used. An address needs to be assigned to the development board.I listened to the vi...
chenbingjy Linux and Android
Detailed analysis of register structure.doc
Detailed analysis of register structure.doc...
zxopenljx FPGA/CPLD
How to use angular velocity sensor to judge whether the vehicle is turning?
If RT uses an angular velocity sensor, does it require the sensor to be installed horizontally with the ground plane? How to determine the current rotation angle? Please help, thank you...
hanker510 MCU
Regarding the capacitor problem at the ADC input
This is the circuit diagram of an infrared tube touch screen in my hand, and part of it is as shown in the figure. The analog data collected by a channel is input from D1-9, and under the control of U...
yup1983 Analog electronics
Using Ginkgo adapter to control sensors with Android devices
[align=center][b][font=宋体]Use[/font]Ginkgo adapter to realize Android device to control sensor[/b][/align][align=left][color=rgb(0, 0, 0)][font=宋体][size=12pt] [/size][/font][/color][/align][align=left...
vt2017 Mobile and portable

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2727  1152  1757  2063  559  55  24  36  42  12 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号