EEWORLDEEWORLDEEWORLD

Part Number

Search

315S24XFR-Y

Description
Analog Circuit
File Size105KB,4 Pages
ManufacturerMartek Power Inc
Websitehttp://www.martekpower.com
Download Datasheet Parametric View All

315S24XFR-Y Overview

Analog Circuit

315S24XFR-Y Parametric

Parameter NameAttribute value
Objectid105996173
package instruction,
Reach Compliance Codeunknown
YTEOL0
www.martekpower.com
300XFR series
Single & Dual Output
DC/DC Converter
NEW
Approved for New Designs
F
EATURES
Up to 81% Efficiency
Single and Dual Output, 3 watt converter
Available in 5, 12, 24 and 48 VDC Inputs
2 - 1 Input Range
Industry Standard Pin out
Short Circuit Protection
D
ESCRIPTIONS
The 300XFR series power modules are high efficiency, low-
profile, 3 watt dc-dc converters that operate over input voltage
ranges of 4.5 - 9 VDC, 9 - 18 VDC, 18 - 36 VDC and 36 - 75 VDC
and provide precisely regulated output voltages of 5V, 12V, 15V,
±12V and ±15V.
The -40
o
C to +71
o
C operating temperature range makes it ideal
for data communication equipment, mobile battery driven
equipment, distributed power systems, telecommunication
equipment, mixed analog/digital subsystems, process/
machine control equipment, computer peripheral systems and
industrial robot systems.
I
NPUT
C
HARACTERISTICS
Min
Input Voltage
5 VDC Input Models
4.5
12 VDC Input Models
9
24 VDC Input Models
18
48 VDC Input Models
36
Under Voltage Shut Down
5 VDC Input Models
12 VDC Input Models
24 VDC Input Models
48 VDC Input Models
Input Fuse Requirements
5 VDC Input Models
12 VDC Input Models
24 VDC Input Models
48 VDC Input Models
Reverse Polarity Input Current
Short Circuit Input Power
Input Filter
Typ Max Unit/Comments
5
12
24
48
9
18
36
75
4
8.5
17
34
1500
700
350
135
VDC
VDC
VDC
VDC
VDC
VDC
VDC
VDC
O
UTPUT
C
HARACTERISTICS
Output Voltage Set Point
Output Voltage Balance
Line Regulation
Min Typ Max Unit/Comments
±0.5 ±2.0 % Output voltage at
nominal line & FL
±0.5 ±2.0 % Equal Output
Loads
±0.2 ±0.5 % Output voltage
measured from
min. input line to
maximum
±0.2 ±0.5 % Output voltage
measured from FL
to 10% load
45 60 mV p-p, Nom.Line
@FL, 20MHz B.W.,
using 1
μf
bypass
capacitor
100 mV p-p, Over Line,
Load & Temp., 20
MHz B.W.,
using 1
μf
bypass
capacitor
Continuous,
Automatic Recovery
±3 ±5 % deviation of Vout
for a 25% load
change
300 500
μS
for 25% load
change
±0.01 ±0.02 % per degree C
mA; Slow blow type
mA; Slow blow type
mA; Slow blow type
mA; Slow blow type
1 Amp
1000 1500 mW
Pi Filter
Load Regulation
Ripple/Noise
G
ENERAL
C
HARACTERISTICS
Switching Frequency
Isolation Voltage
Isolation Resistance
Isolation Capacitance
MTBF (MIL-HBK-217F)
Min Typ Max Unit/Comments
kHz
300
VDC, 1 minute
500
Mohm, 500VDC
1000
500 pF, 100kHz, 1Volt
Million Hours,
1
+25
o
C, Ground
Benign
Ripple/Noise
Short Circuit Protection
Transient Response
Deviation
Transient Recovery Time
Temperature Coefficient
>> B-60
1111 Knox Street
Torrance
CA 90502
USA
Tel: +1 310 202 8820
sales@martekpower.com

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 963  958  507  1841  2805  20  11  38  57  54 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号