85/86 - 5/8 ” Square Single-Turn Panel Control with Rotary Switch
Potentiometer Specifications
Initial Electrical Characteristics
1
Conductive Plastic Element
Cermet Element
Standard Resistance Range
Linear Tapers (A, B, E, & H) ..................................................................(B & E) 1 K ohms to 1 megohm ............. (A & H) 100 ohms to 1 megohm
Audio Tapers (C, D, F, G, S, & T) .........................................................(D, G, S, & T) 1 K ohms to 1 megohm ... (C & F) 1 K ohms to 1 megohm
Total Resistance Tolerance .........................................................................±20 % or 10 % ...................................... ±10 % or 5 %
Absolute Minimum Resistance ...................................................................2 ohms maximum .................................. 2 ohms maximum
Operating Temperature Range ...................................................................-40 °C to +125 °C.................................. -40 °C to +125 °C
Storage Temperature Range ......................................................................-55 °C to +125 °C.................................. -55 °C to +125 °C
Temperature Coefficient Over Storage Temperature Range ......................±1,000 ppm/°C ...................................... ±150 ppm/°C
Vibration (Single Section) ...........................................................................15 G ....................................................... 15 G
Total Resistance Shift ...........................................................................±2 % maximum ..................................... ±2 % maximum
Voltage Ratio Shift ................................................................................±5 % maximum ..................................... ±5 % maximum
Shock (Single Section) ...............................................................................30 G ....................................................... 30 G
Total Resistance Shift ...........................................................................±2 % maximum ..................................... ±2 % maximum
Voltage Ratio Shift ................................................................................±5 % maximum ..................................... ±5 % maximum
Total Resistance Shift ...........................................................................±10 % maximum ................................... ±5 % maximum
Rotational Life (No Load) ............................................................................100,000 cycles ...................................... 100,000 cycles
Total Resistance Shift ...........................................................................(Linear taper) 10 ohms or ..................... (All tapers) ±5 % TRS maximum
Moisture Resistance (MIL-STD-202, Method 103, Condition B)
Total Resistance Shift ...........................................................................(B & E tapers) ±10 % maximum ........... ±5 % maximum (all tapers)
IP Rating .....................................................................................................IP 40 ...................................................... IP 40
Starting and Running Torque (Non-Locking Bushings)
Single Section ................................................................................................................................................................. 0.14 to 1.06 N-cm (0.2 to 1.5 oz.-in.)
Dual Section .................................................................................................................................................................... 0.14 to 1.06 N-cm (0.2 to 1.5 oz.-in.)
Triple Section ................................................................................................................................................................... 0.35 to 1.41 N-cm (0.5 to 2.0 oz.-in.)
Quadruple Section .......................................................................................................................................................... 0.35 to 1.41 N-cm (0.5 to 2.0 oz.-in.)
Starting and Running Torque (Locking Bushings) ..................................................................................................... 0.14 to 2.82 N-cm (0.2 to 4.0 oz.-in.)
Shaft Locking Torque with Locknut @ 10 in-lb. (B & E Bushings) ........................................................................................................ 14 N-cm (20 oz-in.)
Mounting ...................................................................................................................................................................1.7-2.0 N-m (15-18 lb.-in.) maximum
Weight (Single Section).............................................................................................................................................................................. 21 grams maximum
(Each Additional Section) ...................................................................................................................................................................... 6 grams maximum
Terminals .......................................................................................................................................................................... Printed circuit terminals or J-Hooks
Soldering Condition .................................................................. Recommended hand soldering using Sn95/Ag5 no clean solder, 0.025 ” wire diameter.
Maximum temperature 399 °C (750 °F) for 3 seconds. No wash process to be used with no clean flux.
Marking.......................................................................... Manufacturer’s trademark, wiring diagram, date code and resistance, manufacturer’s part number
Ganging (multiple section potentiometers) ..................................................................................................................................................... 4 cup maximum
Hardware ...........................................One lockwasher and one mounting nut is shipped with each potentiometer, except where noted in the part number.
For dimensional drawings see pages 3 & 4.
For ordering information see page 5.
NOTE: Model 81/82 performance specifications do not apply to units subjected to printed circuit board cleaning procedures.
1At room ambient: +25 °C nominal and 50 % relative humidity nominal, except as noted.
*RoHS Directive 2002/95/EC Jan 27, 2003 including Annex.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications
81/82 - 5/8 ” Square Single-Turn Panel Control
85/86 - 5/8 ” Square Single-Turn Panel Control with Rotary Switch
Rotary Switch Specifications
Initial Electrical Characteristics
1
Contacts:
DPST ...............................................................................................................................................................................N.O/N.O.,N.C./N.C. or N.O./N.C.
DPDT ................................................................................................................................................................................2 N.O./N.C. (break before make)
Power Rating (Resistive Load):
DPST ............................................................................................................ 2 A @ 125 volts RMS-60 Hz or 2 A @ 28 VDC, 1 A @ 250 volts RMS-60 Hz
DPDT ........................................................................................................................................................... 1 A @ 125 volts RMS-60 Hz or 1 A @ 28 VDC
Operating Temperature Range ...........................................................................................................................................................................0 °C to +70 °C
Storage Temperature Range ........................................................................................................................................................................ -65 °C to +125 °C
Vibration (Dual Section) ....................................................................................................................................................................................................... 8 G
(Triple Section) .................................................................................................................................................................................................... 5 G
(Quadruple Section) ........................................................................................................................................................................................... 3 G
Contact Resistance ........................................................................................................................................................................ 10 milliohms maximum
Contact Bounce ......................................................................................................................................................................... 0.1 millisecond maximum
Shock (Dual Section) ......................................................................................................................................................................................................... 20 G
(Triple Section) ...................................................................................................................................................................................................... 15 G
(Quadruple Section) ............................................................................................................................................................................................. 10 G
Contact Resistance ........................................................................................................................................................................ 10 milliohms maximum
Contact Bounce ......................................................................................................................................................................... 0.1 millisecond maximum
Rotational Life ..................................................................................................................................................................................................... 25,000 cycles
Switch Actuating Torque (50% Duty cycle @ Rated Power Load) .................................................................................. 1.41 to 4.94 N-cm (2 to 7 oz.-in.)
Contact Resistance ...................................................................................................................................................................... 100 milliohms maximum
Moisture Resistance (MIL-STD-202, Method 106, Condition B)
Contact Resistance (0.1 VDC-10 mA) ............................................................................................................................................ 10 milliohms maximum
Switch Housing Material ................................................................................................................. High temperature, flame retardant, thermosetting plastic
Mechanical Characteristics
1
Actuating Torque (Each Section, Switch Module Only) ....................................................................................................... 3.53 to 10.6 N-cm (5 to 15 oz.-in.)
Running Torque (Out of Detent, 2-4 Module Assembly)..................................................................................................... 0.21 to 1.41 N-cm (0.3 to 2 oz.-in.)
Detent ..................................................................................................................................................................................................... CW or CCW standard
Contact Materials ..........................................................................................................................................................................Fine silver with gold overlay
Terminal Styles .................................................................................................................................................................................................. Solder lug only
Standard Orientation ..............................................................................................................................................................In-line with control terminals
Optional .......................................................................................................................................................................... Rotated 90 ° CCW from standard
Terminal Strength (Before and After Soldering Heat Exposure) .......................................................................................................... 0.9 Kg (2 lbs.) minimum
NOTE: Model 81/82 performance specifications do not apply to units subjected to printed circuit board cleaning procedures.
1At room ambient: +25 °C nominal and 50 % relative humidity nominal, except as noted.
Specifications are subject to change without notice.
Customers should verify actual device performance in their specific applications
When I saw someone writing a CE browser program on the Internet, his code was: extern "C" DWORD __stdcall SetProcPermissions(DWORD); extern "C" DWORD __stdcall GetCurrentPermissions(); CWnd *pWnd = NU...
[p=16, null, left][color=rgb(51, 51, 51)][font=Arial, Helvetica, sans-serif, 宋体][size=12px]Designers sometimes find op amp data sheet specifications confusing because not all performance characteristi...
[i=s] This post was last edited by Sevenfee on 2018-11-6 20:32 [/i] [size=14px]Using PIC16F887 microcontroller to generate square wave, when I set the square wave frequency to 4KHz, the waveform is no...
Realize constant pressure control of gas circuitProject budget:¥5,000~10,000
Development cycle: 60 days
Project Category: Embedded
Bidding requirements:Project tag:Constant pressure controlProject Des...
I bought an ESP8266MOD module, but I don't know how to write the program to it. This module has a USB interface. I want to use ESP8266_RTOS_SDK to develop the program...
PV DC fuses are safety devices used to protect PV panels, inverters, and DC loads. To ensure their safety and reliability, they must be UL248 certified.
Before applying for UL248 certifi...[Details]
To enable real-time monitoring of home security and automatically dial a number for voice prompts or send text messages when an alarm occurs, a GPRS-based embedded telephone alarm system was design...[Details]
Some time ago, I attended the 4th Energy Chemistry Forum of the Chinese Chemical Society and learned about high-energy-density and high-safety batteries. I would like to summarize and share this wi...[Details]
Electric vehicles are currently gaining momentum, but this is just a facade. Fuel-powered vehicles remain unchallenged. While electric vehicles boast unique advantages in environmental emissions an...[Details]
Definition of interactive projection system:
Interactive projection systems, also known as multimedia interactive projection, are available in floor, wall, and tabletop interactive projection....[Details]
With the rapid advancement of automation technology, collaboration between robots is no longer just science fiction. Imagine dozens of machines moving goods in a warehouse without interfering with ...[Details]
Recently, AstroBo Robot, a subsidiary of Chenxing Automation, launched a new mobile collaborative palletizing product. Leveraging an omnidirectional mobile chassis, an intelligent scheduling system...[Details]
On August 21st, Zhiyuan Robotics revealed at its first partner conference that it expects shipments to reach thousands of units this year and tens of thousands next year. The company hopes to reach...[Details]
1 Source of creativity
With the further development of electronic technology, electronic pets have gradually entered people's family life. At present, there are two main categories of relative...[Details]
In June 2014, the Ministry of Industry and Information Technology issued 4G FD-LTE licenses to China Unicom and China Telecom. Together with the 4G TD-LTE licenses issued to China Mobile, China Uni...[Details]
With the development of science, the use of variable frequency technology is becoming more and more widespread, and it is used in both industrial equipment and household appliances. Inverter air co...[Details]
One of the most core components of electric vehicles is the motor. The power supply provides electrical energy to the motor, which converts this electrical energy into mechanical energy, which in t...[Details]
Coal mines typically contain gas and coal dust. When gas and coal dust reach a certain concentration, they can cause explosions. Electrical equipment generates arcs during normal operation or durin...[Details]
In daily life, power transformers have different functions and uses due to different usage scenarios. The most common ones can be divided into: control transformers, isolation transformers, rectifi...[Details]
1. Fault phenomenon and cause analysis
1. During the operation of the equipment, the expansion sleeve is subjected to a large torque, and the mating surfaces of the shaft and the sleeve move...[Details]