EEWORLDEEWORLDEEWORLD

Part Number

Search

38-R126D4

Description
POWER/SIGNAL RELAY, SPST, MOMENTARY, 5000mW (COIL), PANEL MOUNT
CategoryMechanical and electronic products    relay   
File Size232KB,2 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Download Datasheet Parametric View All

38-R126D4 Overview

POWER/SIGNAL RELAY, SPST, MOMENTARY, 5000mW (COIL), PANEL MOUNT

38-R126D4 Parametric

Parameter NameAttribute value
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresCOIL OPERATE VOLTAGE(AC): 305 V, COIL RELEASE VOLTAGE(AC): 60 V
body width46.2 mm
body height51.6 mm
Body length or diameter46.2 mm
Coil current (AC) maximum value0.03 A
Coil power5000 mW
Coil resistance15200 Ω
Maximum coil voltage (AC)452 V
Coil/Input Power TypeAC
Contact/Output Power TypeAC
Electrical life250000 Cycle(s)
Manufacturer's serial number38
Installation featuresPANEL MOUNT
physical size46.2mm X 46.2mm X 51.6mm
GuidelineUL
Relay actionMOMENTARY
Relay functionSPST
Relay typePOWER/SIGNAL RELAY
surface mountNO
Termination typeQUICK CONNECT
Base Number Matches1
Catalog 1308242
Issued 3-03
PRODUCTS UNLIMITED
38
series
Potential Motor Starting Relay
1-pole, 35A, Normally Closed
AC Coil
File E83865
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that users also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Features
• Single-pole, normally closed relay used extensively in HVAC applications.
• Variety of mounting positions and brackets.
• Convenient 0.250” (6.35 mm) quick connect terminals.
• Custom-built to meet customer requirements.
Coil Data @ 25°C
Voltage:
130, 170, 214, 256, 336, 395, 420 and 495 VAC, 60 Hz.
Nominal Sealed Power:
5 VA).
Insulation Class:
UL Class B (130°C).
Duty Cycle:
Continuous.
Contact Data @ 25°C
Arrangements:
Normally-Closed.
Materials:
Silver cadmium oxide.
Maximum Rating:
35A inductive @ 277VAC, 0.5 power factor (Break only.)
Expected Life:
750,000 ops, mechanical.
250,000 ops., breaking rated load.
Mechanical Data
Termination:
0.250” (6.35 mm) quick connects (single or dual, model
dependent). Terminals #4 & #6 are dummies for customer
convenience.
Mounting Position:
Each model is calibrated for its specified mounting
position. Pick-up voltage may vary if relay is mounted
in positions other than specified.
Weight:
5.76 oz. (163.8 g) approximately
Initial Dielectric Strength
Initial Breakdown Voltage:
1,554 VAC @ 60 Hz. between live parts and
exposed non-current carrying metal parts.
Ordering Information
Typical Part No.
B
38
-A
144
C
3
000
1. Series:
38 = 1-pole, normally-closed, potential motor starting relay
2. Wiring and Terminal Type (number of QCs at given base locations):
A = 2 @ loc. 1, 2 @ loc. 2, 4 @ loc. 3, 2 @ loc. 5 and 2 @ loc. 6.
D = 2 @ loc. 1, 2 @ loc. 2, 4 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
M = 2 @ loc. 1, 2 @ loc. 2, 2 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
R = 1 @ loc. 1, 2 @ loc. 2, 0 @ loc. 3, 1 @ loc. 5 and 0 @ loc. 6.
S = 1 @ loc. 1, 2 @ loc. 2, 0 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
T = 2 @ loc. 1, 2 @ loc. 2, 0 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
Y = 1 @ loc. 1, 2 @ loc. 2, 4 @ loc. 3, 2 @ loc. 5 and 0 @ loc. 6.
3. Coil Rating and Calibration:
000-999 = See table on following page for details.
4. Mounting Bracket Style:
C, D, F or J = See drawings below for details.
C
1.59
(40.39)
#8-32
UNC-2B THD.
D
F
J
.500
(12.7)
#8-32
UNC-2B THD.
1.00
(25.4)
1.563
(39.7)
5. Mounting Position:
1, 2, 3, 4, 5 & 6 = See drawings below for details. NOTE: Devices calibrated in specified mounting position only.
1
2
3
4
5
6
6. Customer ID Suffix:
000-999 = Factory assigned customer ID
Standard part numbers listed below are more likely to be available from stock.
Custom parts only.
Dimensions are shown for
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
818
reference purposes only.
CCS single-step debugging problem, hope God can help
I would like to ask, when I am single-step debugging in CCS, I get stuck in the delay function and cannot get out. I can't jump over it even if I click Step over. How can I skip the delay function? {:...
威斯特法伦v17 Microcontroller MCU
Questions about Buck circuit load
I would like to ask you, can the load of the BUCK circuit be connected to an inductive load? For example, a DC motor...
王小明A Analog electronics
After studying or working, have a laugh~hahahaha
1.姐不是蒙娜丽莎,不会对每个人都微笑。    2.哥吸烟是因为它伤肺、不伤心!    3.没了寂寞,谁陪我。    4.你信不信我一巴掌把你拍墙上,抠都抠不下来!    5.能被抢走的爱人,那不叫爱人。    6.你要是鮮花,以后牛都不敢拉屎了!    7.那些允许被挥霍的年代叫做青春    8.做有良心的男人、找有气质的女人。    9.我怀旧 – 是因为我看不到未来。    10.我太佩服我...
张无忌1987 Talking
About IO port issues
I have been struggling with the REN, OUT, and DIR issues of the IO port for some time. Finally, I think this diagram summarizes it in detail. Here is a summary of the usage of PxDIRx, PxRENx, and PxOU...
sjwh Microcontroller MCU
How to make the power supply of the microcontroller
I am using a 51 chip like voltage and current. How much current does 51 usually use? How should I make the power supply part?...
ljlixian1 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1578  2580  16  1670  1933  32  52  1  34  39 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号