EEWORLDEEWORLDEEWORLD

Part Number

Search

TBJB226M010RDSZ0724

Description
Tantalum Capacitor, Polarized, Tantalum, 10V, 20% +Tol, 20% -Tol, 22uF, 1411,
CategoryPassive components    capacitor   
File Size163KB,7 Pages
ManufacturerAVX
Environmental Compliance
Download Datasheet Parametric View All

TBJB226M010RDSZ0724 Overview

Tantalum Capacitor, Polarized, Tantalum, 10V, 20% +Tol, 20% -Tol, 22uF, 1411,

TBJB226M010RDSZ0724 Parametric

Parameter NameAttribute value
positive tolerance20%
Rated (DC) voltage (URdc)10 V
Capacitor typeTANTALUM CAPACITOR
dielectric materialsTANTALUM (DRY/SOLID)
Installation featuresSURFACE MOUNT
negative tolerance20%
polarityPOLARIZED
capacitance22 µF
ESR1880 mΩ
size code1411
length3.5 mm
width2.8 mm
high1.9 mm
JESD-609 codee3
method of packingTR, 7 Inch
surface mountYES
Terminal surfaceMATTE TIN
Terminal shapeJ BEND
Number of terminals2
Package formSMT
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Is it Rohs certified?Yes
package instruction, 1411
Reach Compliance Codecompliant
ECCN codeEAR99
Is SamacsysN
YTEOL7.46
Objectid249476846
TBJ Series
COTS-Plus – SRC9000 Space Level
The TBJ COTS-Plus –SRC9000 series has
been refined to incorporate only those com-
mercially up-screened ratings which have
been deemed suitable for mission critical and
space level applications.
These capacitors have a more conservative
design approach when compared to other
up-screened components utilizing estab-
lished CV powders and higher dielectric for-
mation ratios. The DCL is typically 25% lower
while still offering aggressive ESR values.
Currently there are 5 case sizes available with
a 6th in development to expand the maxi-
mum capacitance available in a given voltage
range.
These ratings are available with Weibull
grading (B and C), surge current testing
MIL-PRF-55365 Rev. G (A, B, C), optional
Group A from MIL-PRF-55365, and the
extensive SRC9000 space level screening.
CASE DIMENSIONS:
millimeters (inches)
Code
L
W
EIA
Code
1206
1210
2312
2917
2917
EIA
Metric
3216-18
3528-21
6032-28
7343-31
7343-43
L±0.20
(0.008)
3.20 (0.126)
3.50 (0.138)
6.00 (0.236)
7.30 (0.287)
7.30 (0.287)
W+0.20 (0.008)
-0.10 (0.004)
1.60 (0.063)
2.80 (0.110)
3.20 (0.126)
4.30 (0.169)
4.30 (0.169)
H+0.20 (0.008)
-0.10 (0.004)
1.60 (0.063)
1.90 (0.075)
2.60 (0.102)
2.90 (0.114)
4.10 (0.162)
W
1
±0.20
(0.008)
1.20 (0.047)
2.20 (0.087)
2.20 (0.087)
2.40 (0.094)
2.40 (0.094)
A+0.30 (0.012)
-0.20 (0.008)
0.80 (0.031)
0.80 (0.031)
1.30 (0.051)
1.30 (0.051)
1.30 (0.051)
S Min.
1.10 (0.043)
1.40 (0.055)
2.90 (0.114)
4.40 (0.173)
4.40 (0.173)
A
B
C
D
E
H
A
S
A
W
1
W
1
dimension applies to the termination width for A dimensional area only.
Capacitance
Code
104
154
224
334
474
684
105
155
225
335
A(7000)
A(7000)
A(3500, 4550)
A(3500, 3750)
B(4500)
A(2000, 3160)
B(1500, 3160)
A(1500, 2000)
B(1200, 2650)
C(2500)
B(800, 2200)
C(2000)
B(800, 2000)
B(600, 1100)
C(350, 700)
D(1100)
C(300, 590)
C(350, 540)
D(200, 340)
D(150, 490)
D(150, 450)
E(150, 450)
E(150, 300)
U
A(10000)
A(3000, 6630)
A(3000, 5640)
A(3000, 4550)
A(2500, 3750)
B(1300, 3740)
A(1800, 2500)
B(1000, 3160)
B(1000, 2650)
C(2000)
B(1000, 2200)
C(500, 800)
B(500, 1400)
C(400, 750)
D(1100)
C(400, 650)
D(150, 650)
C(300, 590)
D(250, 590)
D(200, 540)
D(200, 490)
E(125, 490)
E(150, 300)
U
μF
6.3V (J)
10V (A)
16V (C)
Rated Voltage DC (V
R
) to 85°C
20V (D)
25V (E)
35V (V)
A(20000)
A(6000, 16470)
A(6000, 13710)
A(6000, 11280)
A(4000, 9530)
A(6000, 8000)
A(3000, 6630)
B(2000, 3400)
A(2000, 3100)
B(2500, 5460)
B(2000, 4550)
B(1000, 3740)
C(800, 1840)
D(2000)
B(1500, 2200)
C(600, 1410)
D(1500)
C(600, 1070)
D(1300)
C(600, 800)
D(250, 800)
D(225, 720)
50V (T)
0.1
0.15
0.22
0.33
0.47
0.68
1.0
1.5
2.2
3.3
A(7000, 9530)
A(6000, 7980)
A(3000, 6630)
A(3000, 5640)
B(5000)
A(1600, 2900)
B(1200, 4550)
B(2000, 3740)
A(7000, 7500)
A(7000)
B(5000)
B(2000, 4000)
B(2000, 3400)
C(3000)
C(1500, 2500)
C(1000, 1700)
D(1200, 2000)
C(1000, 1400)
D(800, 1100)
4.7
475
A(2000, 2900)
A(1800, 4000)
B(3000)
A(1500, 2000)
B(3000)
A(1500, 2030)
B(700, 2030)
A(900, 1700)
B(600, 1880)
C(2000)
B(600, 1740)
C(1800)
B(500, 1620)
C(250, 540)
C(200, 490)
C(300, 440)
C(300, 500)
D(150, 400)
D(150, 360)
D(400)
E(150, 330)
E(200, 250)
A(1800, 2200)
B(800, 2200)
A(1000, 1800)
B(600, 2030)
C(2000)
B(700, 1800)
B(650, 1000)
C(300, 590)
D(1100)
C(300, 540)
D(400)
C(300, 490)
C(200, 500)
D(150, 440)
E(100, 440)
D(150, 400)
E(150, 400)
D(500)
E(150, 360)
E(100, 300)
U
B(1000, 3160)
B(1000, 1500)
C(600, 1070)
C(600, 800)
D(1200)
C(500, 720)
D(300, 720)
D(300, 650)
D(600, 900)
6.8
10
15
685
106
156
D(700)
E(300, 700)
U
22
226
D(200, 650)
33
47
68
100
150
220
330
470
1000
336
476
686
107
157
227
337
477
108
D(400, 590)
D(250, 540)
E(150, 540)
U
E(250, 590)
U
Available Ratings: ESR limits quoted in brackets (Ohms)
Engineering samples - please contact manufacturer
*Codes under development - subject to change.
Notes: Voltage ratings are minimum values. AVX reserves the right to supply
higher ratings in the same case size, to the same reliability standards.
MARCH 2013
35
What is your understanding of Article 82 of the Labor Contract Law of the People’s Republic of China?
[i=s]This post was last edited by yhyworld on 2020-4-19 22:00[/i]The following figure shows Article 82 of the Labor Contract Law of the People's Republic of China.On March 25 this year, the company fo...
yhyworld Talking about work
Activity: Share your first post on EEWORLD
:) Review your first steps in EEWORLDOh my god, I actually quoted a cat. May the cat be happy....
soso Talking
Aeroflex 5800 Series Equipment Meets Evolving Automated Test Needs
If you are an engineer and are doing mixed signal testing, device programming, functional testing, in-system programming, or simple protocol communications, the 5800 Series [url=http://www.eetchina.co...
clj2004000 PCB Design
【KW41Z】Environment construction gcc+jlink
[i=s]This post was last edited by lzwml on 2017-7-1 14:38[/i] [b][color=#5E7384]This content was originally created by [size=3]lzwml[/size], a netizen on the EEWORLD forum. If you want to reprint or u...
lzwml NXP MCU
【MXCHIP Open1081】Why can't IAR download the program?
When using IA77.0 and ST-LINK to program Open1081, the program cannot be downloaded to the chip. The prompt is: Fatal error: There were warnings during download of FLASH loader, see Log Window Session...
dontium RF/Wirelessly
Today I can calm down and study LPC
Finally, the defense is over. Today, I can calm down and study LPC. Haha, the administrator even called me. I feel so sorry. I must study it carefully and at least fulfill my original promise! Haha! N...
dxhuo Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1755  59  733  1402  1472  36  2  15  29  30 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号