Description
Fixed Resistor, Thin Film, 1W, 298000ohm, 200V, 0.05% +/-Tol, 25ppm/Cel, 2512,
CategoryPassive components    The resistor   
File Size342KB,1 Pages
ManufacturerRCD Components Inc.
Websitehttp://www.rcdcomponents.com/
Environmental Compliance
Download Datasheet Parametric View All

BLU2512-2983-AB25W Overview

Fixed Resistor, Thin Film, 1W, 298000ohm, 200V, 0.05% +/-Tol, 25ppm/Cel, 2512,

BLU2512-2983-AB25W Parametric

Parameter NameAttribute value
Package length6.3 mm
Package width3.2 mm
Package height0.61 mm
Is it Rohs certified?Yes
Is SamacsysN
YTEOL7
Objectid739427258
Reach Compliance Codecompliant
Country Of OriginTaiwan
ECCN codeEAR99
Rated temperature70 °C
surface mountYES
Operating Voltage200 V
Other featuresULTRA PRECISION
Number of terminals2
method of packingBULK
Terminal surfaceMatte Tin (Sn) - with Nickel (Ni) barrier
Terminal shapeWRAPAROUND
structureRectangular
JESD-609 codee3
Rated power dissipation(P)1 W
size code2512
technologyTHIN FILM
Tolerance0.05%
Temperature Coefficient25 ppm/°C
Installation featuresSURFACE MOUNT
Package formSMT
resistance298000 Ω
Resistor typeFIXED RESISTOR
Minimum operating temperature-55 °C
Maximum operating temperature155 °C
TSP distributed control increases test speed and reduces test costs
TSP technology enhances instrument control by allowing users to use standard PC control or create embedded test scripts that execute on the microprocessor within the instrument. By using TSP test scri...
Jack_ma Test/Measurement
Please help look at this program!
#include#pragma vector = PORT1_VECTOR __interrupt void Port_1(void) { volatile unsigned int i; // volatileWhen programming the source code, do not use optimization for this variablefor (i = 0; i30000;...
Hsiang Microcontroller MCU
Orcad Capture CIS automatically numbers after deleting a component, and DRC appears when importing the netlist into Allegro
For example, I drew 10 resistors, numbered R1~R10, and the connections were already drawn in Allegro. Then I deleted R5 in the schematic, renumbered it automatically, and then imported it into the net...
ayu_ag PCB Design
Blood oxygen saturation is detected by receiving the energy ratio of infrared light and red light, and then it can be calculated by adding an algorithm. Then the heart rate...
Blood oxygen saturation is detected by receiving the energy ratio of infrared light and red light, and then it can be calculated by adding an algorithm. So how is heart rate detection achieved? What a...
QWE4562009 Discrete Device
ActiveSync installation error
I encountered an error when installing ActiveSync. The error message was "Error writing to file: C:\Program Files\Microsoft ActiveSync\wcesmgr.exe, please verify that you have access to the directory....
han0602 Embedded System
The 2450 board runs fine at 400M, but crashes when playing CMMB TV at 533M???
Dear hardware and software experts, this problem has puzzled me for a long time. Could you please analyze the reason? Can Shuiyan also help analyze it? The problem is this: We use Samsung's S3C2450 pl...
qiaoli Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 888  1277  2864  239  1858  18  26  58  5  38 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号