EEWORLDEEWORLDEEWORLD

Part Number

Search

5145.ABTWF075C0.611

Description
Mains Power Connector, 8A, 125/250VAC, Male,
CategoryThe connector    The connector   
File Size524KB,4 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Download Datasheet Parametric View All

5145.ABTWF075C0.611 Overview

Mains Power Connector, 8A, 125/250VAC, Male,

5145.ABTWF075C0.611 Parametric

Parameter NameAttribute value
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresSTANDARDS: IEC/EN 60950; UL 94V-0; CSA; VDE, QUICK CONNECT
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationTIN COPPER
Contact completed and terminatedTIN
Contact point genderMALE
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
JESD-609 codee3
MIL complianceNO
Power Connector Ratings8A, 125/250VAC
Installation typePANEL
OptionsGENERAL PURPOSE
Shell materialPOLYETHYLENE
Total number of contacts3
Base Number Matches1
POWER ENTRY MODULES /
GERÄTESTECKER-KOMBIELEMENTE
Power entry module Type 5145
– Panel mount: screw-on version, front-side
– Appliance inlet, circuit breaker type TA 45 and line filter
5145
Standard or
Medical filter
50
75
100
Characteristics
• Circuit breaker with line switch, 2-pole, non-illuminated or
illuminated
• Combined with thermal overload protection
• Optional with undervoltage- or remote trip release
• All single elements wired
Unwired versions available on request
Technical data
Rated voltage
Rated currents I
n1
)
125/250 VAC; 50/60 Hz
1–10 A; @T
a
40 °C; SEV, VDE, Semko
1–15 A; @T
a
40 °C; UL, CSA
0,1–10 A; VDE, see table 1
0,1–15 A; UL/CSA, see table 1
< 0,5 mA (250 V/60 Hz)
< 5 µA (250 V/60 Hz)
1,7 kVDC between L-N
2,7 kVDC between L/N-PE
–10 °C to +55 °C
10/055/21 acc. to IEC/EN 60068-1
IP 40 acc. to IEC 60529
suitable for equipment with prot. cl. I,
acc. to IEC 61140
quick-connect 6,3 x 0,8 mm
max. 8 mm
Thermoplastic, black, UL94 V–0
Filter
TA 45
Leackage current, Standard
Medical
Test voltage (2 sec)
Allowable ambient air
temperatures T
a
Climatic category
Degree of protection (front-side)
Protection class
Terminals
Panel thickness s
Materials: Housing
Appliance-inlet
acc. to. IEC/EN 60320-1/C14,
Protection class I, pin-temperature 70 °C
(cold condition)
Circuit breaker
acc. to IEC/EN 60934, UL 1077,
type TA45
CSA 22.2 no. 235.
2-pole rocker switch, illuminated or
non-illuminated.
Optional with undervoltage- or remote
trip release
Short circuit capacity Icn:
at In < 3 A / 240 VAC: 10 x In
at In
3 A / 240 VAC: 300 A
Line filter, standard and medical acc. to. IEC 60939, EN 133 200,
UL 1283, CSA C 22.2 no. 8
Technical details see page 202
Application note
The rated current of the line filter must be equal or higher than the
rated current of the circuit-breaker.
1)
126
www.schurter.com
Current control circuit
Current control circuitIf a DAC+op amp controlled current circuit is added to the load output end1.Output load current ≤ 90mA, voltage amplitude 45V, then what is the appropriate sampling resistor? Op...
QWE4562009 Analog electronics
Impedance Measurement Handbook 2nd Edition
Impedance Measurement Handbook 2nd Edition...
wangwei20060608 RF/Wirelessly
I saw this on the internet, what do you think about it?
I saw a company selling GSM positioning products online. What do you think of GSM positioning? http://auction1.paipai.com/BC2E583400000000003C38EF057F5640#nolink...
linyis Embedded System
A good product about virtual sound card
I've been looking for good test products, but most of them are expensive! This one is pretty good...:)...
wuyongming Test/Measurement
Could battery technology make traveling to Mars easier?
I recently watched the movie "The Martian". As an engineer working for a large engineering firm, I was able to relate to Mark Watney’s adventures across the desert surface of Mars (and perhaps other e...
maylove Analogue and Mixed Signal
Questions about f28027ADC sampling program
[b]In the example "F2802x ADC Start-Of-Conversion (SOC) Example Program.", if the length of the uint16_t Voltage1[50] array is greater than 50, an error will be reported when compiling. Why is this? P...
1500231580 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 616  2341  1191  781  2639  13  48  24  16  54 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号