Operating Temperature Range ......................... -40°C to +125°C
Storage Temperature Range ........................... .-65°C to +150°C
Junction Temperature ......................................................+150°C
Lead Temperature (soldering, 10s) ................................. +300°C
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these
or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect
device reliability.
Electrical Characteristics
PARAMETER
Supply Voltage Range
Supply Current
(V
CC
= 1V to 5.5V, T
A
= T
MIN
to T
MAX
, unless otherwise specified. Typical values are at V
CC
= 5V and T
A
= +25°C.) (Note 1)
SYMBOL
V
CC
I
CC
V
TH
V
HYST
t
RD
t
RP
I
RAMP
VTH-RAMP
CONDITIONS
V
CC
≤ 5.0V
V
CC
≤ 3.3V
V
CC
≤ 2.0V
T
A
= +25°C
MIN
1.0
TYP
2.5
1.9
1.6
MAX
5.5
4.2
3.4
2.5
V
TH
+ 1.5%
V
TH
+ 2.5%
UNITS
V
µA
V
CC
Reset Threshold Accuracy
Hysteresis
V
CC
to Reset Delay
Reset Timeout Period
V
SRT
Ramp Current
V
SRT
Ramp Threshold
T
A
= -40°C to +125°C
V
CC
falling at 1mV/µs
C
SRT
= 1500pF
C
SRT
= 0
V
TH
- 1.5%
V
TH
- 2.5%
V
mV
µs
ms
nA
V
mV
4 x V
TH
80
4.375
0.275
240
0.65
33
3.00
5.75
V
SR
T = 0 to 0.65V; V
CC
= 1.6V to 5V
V
CC
= 1.6V to 5V (V
RAMP
rising)
V
RAMP
falling threshold
V
CC
≥ 1.0V, I
SINK
= 50µA
RAMP Threshold Hysteresis
RESET
Output Voltage Low
V
OL
0.3
0.3
0.4
0.8 x V
CC
0.8 x V
CC
0.8 x V
CC
1.0
0.8 x V
CC
0.8 x V
CC
0.8 x V
CC
0.8 x V
CC
0.3
0.3
0.4
V
V
µA
V
V
V
CC
≥ 2.7V, I
SINK
= 1.2mA
V
CC
≥ 4.5V, I
SINK
= 3.2mA
V
CC
≥ 1.8V, I
SOURCE
= 200µA
V
CC
≥ 4.5V, I
SOURCE
= 800µA
V
CC
> V
TH
, reset not asserted
V
CC
≥ 1.0V, I
SOURCE
= 1µA
V
CC
≥ 1.8V, I
SOURCE
= 150µA
V
CC
≥ 2.7V, I
SOURCE
= 500µA
V
CC
≥ 4.5V, I
SOURCE
= 800µA
V
CC
≥ 1.8V, I
SINK
= 500µA
V
CC
≥ 2.7V, I
SINK
= 1.2mA
V
CC
≥ 4.5V, I
SINK
= 3.2mA
RESET
Output Voltage High,
Push-Pull
RESET
Output Leakage Current,
Open-Drain
V
OH
I
LKG
V
CC
≥ 2.25V, I
SOURCE
= 500µA
RESET Output Voltage High
V
OH
RESET Output Voltage Low
V
OL
Note 1:
Devices production tested at +25°C. Overtemperature limits are guaranteed by design.
www.maximintegrated.com
Maxim Integrated
│
2
MAX6340/MAX6421–
MAX6426
Typical Operating Characteristics
Low-Power, SC70/SOT µP Reset Circuits
with Capacitor-Adjustable Reset Timeout Delay
(V
CC
= 5V, C
SRT
= 1500pF, T
A
= +25°C, unless otherwise noted.)
SUPPLY CURRENT
vs. SUPPLY VOLTAGE
MAX6421/26 toc01
MAX6421/26 toc02
RESET TIMEOUT PERIOD (ms)
SUPPLY CURRENT (µA)
3.0
2.5
2.0
1.5
1.0
0.5
0
0
1
2
3
4
5
T
A
= +25°C
T
A
= -40°C
1000
100
10
1
0.1
0.001
RESET TIMEOUT PERIOD (ms)
3.5
T
A
= +125°C
C
SRT
= 1500pF
4.25
4.20
4.15
6
0.01
0.1
1
C
SRT
(nF)
10
100
1000
4.10
-50
-25
0
25
50
75
100
125
SUPPLY VOLTAGE (V)
TEMPERATURE (°C)
MAX6421/26 toc04
MAX6421/26 toc05
550
RESET TIMEOUT PERIOD (µs)
500
450
400
350
300
250
200
-50
-25
0
25
50
75
C
SRT
= 0
150
TRANSIENT DURATION (s)
125
100
75
50
25
V
TH
= 2.95V
0
200
400
600
800
RESET OCCURS
ABOVE THE CURVE
150
V
CC
TO RESET DELAY Sµs)
140
130
120
110
100
90
V
CC
FALLING AT 1mVs
100
125
0
1000
80
-50
-25
0
TEMPERATURE (°C)
RESET THRESHOLD OVERDRIVE (mV)
25
75
50
TEMPERATURE (°C)
100
125
POWER-UP/POWER-DOWN
CHARACTERISTIC
MAX6421/26 toc07
NORMALIZED RESET THRESHOLD
vs. TEMPERATURE
NORMALIZED RESET THRESHOLD
MAX6421/26 toc08
V
CC
V
TH
= 1.6V
1.006
1.004
1.002
1.000
0.998
0.996
0.994
1V/div
1V/div
RESET
400s/div
-50
-25
0
25
50
75
100
125
TEMPERATURE (°C)
www.maximintegrated.com
Maxim Integrated
│
3
MAX6421/26 toc06
600
RESET TIMEOUT PERIOD
vs. TEMPERATURE
175
MAXIMUM TRANSIENT DURATION
vs. RESET THRESHOLD OVERDRIVE
160
V
CC
TO RESET DELAY
vs. TEMPERATURE (V
CC
FALLING)
MAX6421/26 toc03
4.0
10,000
RESET TIMEOUT PERIOD vs. C
SRT
4.30
RESET TIMEOUT PERIOD
vs. TEMPERATURE
MAX6340/MAX6421–
MAX6426
Pin Description
PIN
MAX6340
SOT23
1
MAX6421
MAX6422
MAX6423
SOT143
3
SC70
3
MAX6424
MAX6425
SOT23
5
Low-Power, SC70/SOT µP Reset Circuits
with Capacitor-Adjustable Reset Timeout Delay
MAX6426
SOT23
1
NAME
FUNCTION
SRT
Set Reset Timeout Input. Connect a capacitor between
SRT and ground to set the timeout period. Determine the
period as follows: tRP = 2.73 × 10
6
× C
SRT
+ 275µs with
t
RP
in seconds and C
SRT
in farads
Ground
Not Internally Connected. Can be connected to GND
Supply Voltage and Reset Threshold Monitor Input
RESET
changes from high to low whenever V
CC
drops
below the selected reset threshold voltage.
RESET
remains low for the reset timeout period after V
CC
exceeds
the reset threshold
RESET changes from low to high whenever V
CC
drops
below the selected reset threshold voltage. RESET
remains high for the reset timeout period after V
CC
exceeds the reset threshold
2
3
4
1
—
2
2
—
1
3
4
2
2, 3
—
5
GND
N.C.
V
CC
RESET
5
4
—
4
1
4
—
—
RESET
Detailed Description
Reset Output
The reset output is typically connected to the reset input of
a µP. A µP’s reset input starts or restarts the µP in a known
state. The MAX6340/MAX6421–MAX6426 µP superviso-
ry circuits provide the reset logic to prevent code-execu-
tion errors during power-up, power-down, and brownout
conditions (see
Typical Operating Characteristics).
RESET
changes from high to low whenever V
CC
drops
below the threshold voltage. Once V
CC
exceeds the
threshold voltage,
RESET
remains low for the capaci-
tor-adjustable reset timeout period.
The MAX6422 active-high RESET output is the inverse
logic of the active-low
RESET
output. All device outputs
are guaranteed valid for V
CC
> 1V.
The MAX6340/MAX6423/MAX6425/MAX6426 are open-
drain
RESET
outputs. Connect an external pullup resistor
to any supply from 0 to 5.5V. Select a resistor value large
enough to register a logic low when
RESET
is asserted
and small enough to register a logic high while supply-
ing all input current and leakage paths connected to the
RESET
line. A 10kΩ to 100kΩ pullup is sufficient in most
Professor Zheng Qiang of Zhejiang University's speech: I don't teach in a muddled way, and you shouldn't learn in a muddled way either
Professor Zheng Qiang's words are worth pondering. Will China exp...
The P6.0 IO port of 430 is the 0th channel of AD conversion. If no circuit device is connected, what is the analog voltage of this IO port? Is it 0? I wrote a code for single-channel multiple conversi...
Is the LTE Cat 1 module like the GPRS module, which can be used by simply inserting a common SIM card? Or does it require the cooperation of the operator to activate it like the NB-IOT module?...
[align=center] [b]Latest 08 version of PM4040FL partial upgrade switching power supply application data[/b][/align] [[i] This post was last edited by yuandayuan6999 on 2010-6-1 18:35[/i]]...
A few days ago, I conducted a survey on the creative market ( https://bbs.eeworld.com.cn/thread-106255-4-1.html ), and bkkman's suggestion was: popularize the basic knowledge of the Internet of Things...
[i=s] This post was last edited by zhumj116 on 2016-3-8 22:23 [/i] [color=#444444][font=微软雅黑, arial][size=16px] I worked in Datang Telecom for more than 5 years in FPGA design, and then continued to w...
A line scan lens is an industrial lens used with line scan cameras. Its imaging principle is to capture the image of the workpiece using a linear sensor and then perform digital signal processing t...[Details]
To enable real-time monitoring of home security and automatically dial a number for voice prompts or send text messages when an alarm occurs, a GPRS-based embedded telephone alarm system was design...[Details]
1. Introduction
Electronic scales are gradually replacing traditional measuring tools like springs and balances in everyday life, such as electronic price computing scales and electronic weigh...[Details]
Amidst the wave of intelligent automotive transformation, advanced driver assistance is gradually emerging from cutting-edge technology into the mainstream, becoming a new frontier of industry comp...[Details]
On August 21, WeRide officially launched WePilot AiDrive, a one-stage end-to-end assisted driving solution developed in cooperation with Bosch. This comes only half a year after the two parties' "t...[Details]
Recently, AstroBo Robot, a subsidiary of Chenxing Automation, launched a new mobile collaborative palletizing product. Leveraging an omnidirectional mobile chassis, an intelligent scheduling system...[Details]
Electric vehicles are now widespread, but they've brought with them a host of problems, the most prominent of which is charging. Small electric vehicles (EVs) are a new form of transportation in a ...[Details]
Charging is a familiar process for new energy vehicles, and as a source of battery energy, charging piles are crucial. New energy vehicle charging can be divided into fast charging and slow chargin...[Details]
UPS stands for Uninterruptible Power Supply, which includes energy storage devices. It is mainly used to provide uninterruptible power supply for devices that require high power stability.
...[Details]
According to Nikkei, Japan has performed poorly in responding to China's power semiconductor challenges.
There are five major companies in Japan's power chip market: Mitsubishi Electric,...[Details]
During daily operation of an R-type power transformer, the voltage used varies as the equipment being used adjusts. This raises the question: can the transformer change voltage at this point? The a...[Details]
A patent disclosed by Ford proposes replacing traditional segmented side curtain airbags with integrated full-width side curtain airbags that span the side of the vehicle and can be deployed simult...[Details]
In the field of intelligent driving, regulations are becoming increasingly stringent, and the technical threshold continues to rise. Especially after the traffic accident in March 2025, the Ministr...[Details]
In daily life, when we purchase a transformer, we are faced with the installation and wiring procedures. Generally speaking, large transformers such as power transformers are equipped with speciali...[Details]
introduction
Inverter air conditioners are a trend in the current era and have gradually become commonplace in countless households. Beyond their basic cooling and heating functions, air condi...[Details]