economical solution to the challenge of load-applied
harmonics mitigation in three-phase power systems.
With a plug-and-play approach and more compact
dimensions than comparable products, they can be
quickly installed and easily commissioned. They
increase the reliability and service life of electric
installations, help utilize electric sytem capacity
better, and are the key to meet Power Quality
standards such as IEEE 519. Ecosine filters reshape
your distorted current back to the desired sinusoidal
waveform. Schaffner ecosine filters can be applied to
virtually any kind of power electronics with front-end
six-pulse rectifiers, 3-phase diode or thyristor bridges,
where harmonic current distortion needs to be
reduced to defined limits.
Technical specifications
Nominal operating voltage
Operating frequency
Nominal motor drive input power rating
Total harmonic current distortion THID*
Efficiency
High potential test voltage
Protection category
Cooling
Overload capability
Ambient temperature range
3 x 440 VAC to 500 VAC ±10%
50 Hz ±1 Hz
1.1 to 250 kW
<5% at rated power
>98% for rated voltage and power
P –> E 2160 VAC (1 s)
IP 00, IP 20
Internal fan cooling or external cooling**
1.6x rated current for 1 minute, once per hour
–25°C to +45°C fully operational
+45°C to +70°C derated operation***
–25°C to +85°C transport and storage
UL 94 V-2
Filter: UL 61800-5-1, EN 61800-5-1
Chokes: EN 61558-2-20 or EN 60076-6
>200,000 hours
100 kA
TN, TT, IT
OV III (IEC 60664-1 / UL 61800-5-1)
Typical applications
Equipment with front-end six-pulse rectifier
Motor drives
Factory automation equipment
Water/wastewater treatment facilities
Fan and pump applications
HVAC installations
Mission-critical processes
DC fast chargers
Flammability corresponding to
Design corresponding to
MTBF @ 45°C/500 V (Mil-HB-217F)
SCCR****
Earthing System
Overvoltage category
****System requirements: THVD <2%, line voltage unbalance <1%
** *
Note: performance specifications in this brochure refer to six-pulse diode rectifiers.
****SCR
rectifier front-ends will produce different results, dependent upon the firing angle of the thyristors.
THID ~5% at rated power for filter <6 kW
** Please check the inlet air flow required for cooling table on page 6 of this document.
*** I
derated
= I
nominal
*√((T
max-
T
amb
)/(T
max-
T
nominal
)) = I
nom
*√(70°C-T
amb
)/25°C
**** External UL-rated fuses required. Please consult the user manual.
2
Ecosine passive
Schaffner Group
Datasheets
15 Nov 2018
Filter selection table – IP 00 enclosure
Filter
Rated load power
@ 480 VAC/50 Hz
[kW]
FN 3450-1-110-E0_ _ _ _ _*
FN 3450-2-110-E0_ _ _ _ _*
FN 3450-4-112-E0_ _ _ _ _*
FN 3450-6-112-E0_ _ _ _ _*
FN 3450-8-112-E0_ _ _ _ _*
FN 3450-11-112-E0_ _ _ _ _*
FN 3450-15-113-E0_ _ _ _ _
FN 3450-19-113-E0_ _ _ _ _
FN 3450-22-113-E0_ _ _ _ _
FN 3450-30-115-E0_ _ _ _ _
FN 3450-37-115-E0_ _ _ _ _
FN 3450-45-115-E0_ _ _ _ _
FN 3450-55-115-E0_ _ _ _ _
FN 3450-75-115-E0_ _ _ _ _
FN 3450-90-116-E0_ _ _ _ _
FN 3450-110-116-E0_ _ _ _ _
FN 3450-132-118-E0_ _ _ _ _
FN 3450-160-118-E0_ _ _ _ _**
FN 3450-200-118-E0_ _ _ _ _**
FN 3450-250-118-E0_ _ _ _ _**
1.1
2.2
4
5.5
7.5
11
15
19
22
30
37
45
55
75
90
110
132
160
200
250
Motor drive
input current
[Arms]***
1.5
3
5.5
10
13
16
24
32
38
45
60
75
90
110
150
180
210
260
320
400
Rated filter
input current
[Arms]
1.35
2.75
4.99
6.77
9.24
13.6
18.5
23.3
27.0
36.9
45.4
55.2
67.5
92.5
111
135
163
198
248
310
[kg]
5.8
8.4
11.3
14.0
16.9
20.9
28.2
32.0
36.0
47.5
53.9
63.1
66.8
88.1
120.1
140.6
160.9
181.1
216.8
256.7
110
110
112
112
112
112
113
113
113
115
115
115
115
115
116
116
118
118
118
118
A
A
B
B
C
C
D
D
D
E
E
E
F
F
G
G
H
H
H
H
Weight
Terminal
Frame size
* Filter rating which does not require forced cooling or fan module
** Filter rating which does not require RC damping module for rectifiers with EMI filter
*** Motor drive input current without harmonic filter
Filter power terminals
Terminal designation*
Screw thread
Flex wire AWG
Flex wire
Screw torque value
Max width**
cable lug
[mm
2
]
110
112
113
115
116
118
M3
M4
M6
M8
M8
M10
14-22
10-22
6-18
1/0-8
3/0-8
3/0-500 kcmil
0.4-2.5
0.4-6
0.75-16
10-50
10-95
95-240
[Nm]
0.5
1.2
3
8
8
10
[mm]
7
10
15
15
17
35
A
B, C
D
E, F
G
H
Frame size
* Recommended connector type: wire or cable lug for 110 to 113, only cable lug for 115 to 118
** To fulfill creepage/clearance acc. UL 61800-5-1 without additional protection (insulation). Creepage/clearance can vary depending on applicable standard and must
be reviewed by customer. Creepage/clearance may be reduced when additional protection (insulation) is provided.
Filter signal and earth terminals
Terminal type
Screw thread
Screw torque value
[Nm]
Signal
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
M3*
M5
M6
M6
M8
M8
M10
M10
M10
0.5
4
8
8
14
14
25
25
25
All
A
B
C
D
E
F
G
H
Frame size
* Max width cable lug = 7 mm
3
Ecosine passive
Schaffner Group
Datasheets
15 Nov 2018
Filter selection table – IP 20 enclosure
Filter
Rated load power
@ 480 VAC/50 Hz
[kW]
FN 3450-1-110-E2_ _ _ _ _*
FN 3450-2-110-E2_ _ _ _ _*
FN 3450-4-112-E2_ _ _ _ _*
FN 3450-6-112-E2_ _ _ _ _*
FN 3450-8-112-E2_ _ _ _ _*
FN 3450-11-112-E2_ _ _ _ _*
FN 3450-15-113-E2_ _ _ _ _
FN 3450-19-113-E2_ _ _ _ _
FN 3450-22-113-E2_ _ _ _ _
FN 3450-30-115-E2_ _ _ _ _
FN 3450-37-115-E2_ _ _ _ _
FN 3450-45-115-E2_ _ _ _ _
FN 3450-55-115-E2_ _ _ _ _
FN 3450-75-115-E2_ _ _ _ _
FN 3450-90-116-E2_ _ _ _ _
FN 3450-110-116-E2_ _ _ _ _
FN 3450-132-118-E2_ _ _ _ _
FN 3450-160-118-E2_ _ _ _ _**
FN 3450-200-118-E2_ _ _ _ _**
FN 3450-250-118-E2_ _ _ _ _**
1.1
2.2
4
5.5
7.5
11
15
19
22
30
37
45
55
75
90
110
132
160
200
250
Motor drive
input current
[Arms]***
1.5
3
5.5
10
13
16
24
32
38
45
60
75
90
110
150
180
210
260
320
400
Rated filter
input current
[Arms]
1.35
2.75
4.99
6.77
9.24
13.6
18.5
23.3
27.0
36.9
45.4
55.2
67.5
92.5
111
135
163
198
248
310
[kg]
7
9
13
15
19
23
32
36
40
53
60
69
74
95
129
149
178
198
234
274
110
110
112
112
112
112
113
113
113
115
115
115
115
115
116
116
118
118
118
118
A
A
B
B
C
C
D
D
D
E
E
E
F
F
G
G
H
H
H
H
Weight
Terminal
Frame size
* Filter rating which does not require forced cooling or fan module
** Filter rating which does not require RC damping module for rectifiers with EMI filter
*** Motor drive input current without harmonic filter
Filter power terminals
Terminal designation*
Screw thread
Flex wire AWG
Flex wire
Screw torque value
Max width**
cable lug
[mm
2
]
110
112
113
115
116
118
M3
M4
M6
M8
M8
M10
14-22
10-22
6-18
1/0-8
3/0-8
3/0-500 kcmil
0.4-2.5
0.4-6
0.75-16
10-50
10-95
95-240
[Nm]
0.5
1.2
3
8
8
10
[mm]
7
10
15
15
17
35
A
B, C
D
E, F
G
H
Frame size
* Recommended connector type: wire or cable lug for 110 to 113, only cable lug for 115 to 118
** To fulfill creepage/clearance acc. UL 61800-5-1 without additional protection (insulation). Creepage/clearance can vary depending on applicable standard and must
be reviewed by customer. Creepage/clearance may be reduced when additional protection (insulation) is provided.
Filter signal and earth terminals
Terminal type
Screw thread
Screw torque value
[Nm]
Signal
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
Earth (PE)
M3*
M5
M6
M6
M8
M8
M10
M10
M10
0.5
4
8
8
14
14
25
25
25
All
A
B
C
D
E
F
G
H
Frame size
* Max width cable lug = 7 mm
4
Ecosine passive
Schaffner Group
Datasheets
15 Nov 2018
Product selector
Table 1: Filter configurations if external air flow is available for cooling
(Filters do
not contain fan
and do
not contain aux. power supply)
E0XXXXX
- For rectifiers without DC-link
choke
E0XXJXX
- For rectifiers without DC-link
choke
- Filters contain trap disconnect
jumper
E0XXXRX
- For rectifiers without DC-link
choke and with EMI filter
- Filters contain RC damper
module
E0XXJRX
- For rectifiers without DC-link
choke and with EMI filter
- Filters contain RC damper
module and trap disconnect
jumper
5
Ecosine passive
Schaffner Group
Datasheets
15 Nov 2018
Table 2: Filter configurations with embedded ventilation
(Filters
contain fan
and
aux. power supply)
E0FAXXX and E2FAXXX
- For rectifiers without DC-link
choke
- Filters contain fan, aux. power
supply
E0FAJXX and E2FAJXX
- For rectifiers without DC-link
choke
- Filters contain fan, aux. power
supply and trap disconnect
jumper
E0FAXRX and E2FAXRX
- For rectifiers without DC-link
choke and with EMI filter
- Filters contain fan, aux. power
supply and RC damper module
E0FAJRX and E2FAJRX
- For rectifiers without DC-link
choke and with EMI filter
- Filters contain fan, aux. power
supply, RC damper module and
trap disconnect jumper
Table 3: Filter configurations if external aux. power supply for the fan is available
I would like to share a solution to the confusion in the correspondence between ADC channels and temperature control systems. I hope you will criticize me if there are any unreasonable points! Some ti...
I haven't applied for TI samples for a long time. I tried today but failed. I applied many times before but failed. I don't know why. (School student)...
The UV sterilizer uses the principle of ultraviolet light to disinfect bacteria. The UV LED can generate ultraviolet light in the 260nm~280nm band, directly cutting off bacterial DNA/RNA and completel...
[table=98%] [tr][td]I am writing FPGA programs recently. I have written some small programs before. This time I am writing a larger project, using the cyclone 3 EP3C40 chip. When using this chip, you ...
[i=s]This post was last edited by tiankai001 on 2018-11-29 11:35[/i] [align=left][color=#0000ff][backcolor=rgb(237, 235, 235)][font=微软雅黑][size=4] Radio - this name is familiar to everyone, especially ...
Abstract: This article takes Intel's 80C196 microcontroller and 11-channel 12-bit analog/digital conversion chip TLC2543 as examples to introduce the interface and programming of this type of ADC and ...
This program is written to simulate the serial port hardware mechanism. When used, a timed interrupt can be set with a time interval of 1/4 baud rate. The receiving function is called once for ea...[Details]
introduction
1 The significance of using RTOS on MSP430
It is understandable that it is meaningless to use RTOS on MSP430. Because the hardware resources of MSP430 are limited (for exampl...[Details]
0. Introduction
In daily life, we often see some special-purpose vehicles. When these vehicles pass through intersections, they often obtain the right of way at intersections by temporarily op...[Details]
When choosing a laptop battery, you should consider several factors, such as power, appearance, and quality.
Regarding power, we often see that a manufacturer uses values such as the number ...[Details]
DSP (digital signal processor) is used more and more frequently in today's engineering applications. There are three main reasons for this: first, it has powerful computing power and is capable of ...[Details]
1 Introduction
As an emerging microfabrication technology, micro-electromechanical system (MEMS) technology has begun to be applied in various fields. It can integrate functions such as inform...[Details]
1. Principle of displacement angle sensor
The angle sensor is used to detect angles. It has a hole in its body that fits the LEGO axle. When connected to the RCX, the angle sensor counts once ...[Details]
A multi-point temperature control heating control system was designed using the SST89E564RC single-chip microcomputer and a new temperature measuring device. The heating system can be controlled in...[Details]
my country is a big country in agriculture, grain production and consumption. Grains are a necessary condition for our nation to survive and develop. The flour processing industry will exist forever w...[Details]
Flooded Batteries
This battery developed in Germany can be used to power flashlights, strobe lights and toys as long as it is filled with water. This battery can be stored for 50 years and can...[Details]
Introduction
Liquid crystal, as a display device, is widely used in low-power products such as instruments, meters, and electronic equipment with its unique advantages. In the past, the displ...[Details]
This paper designs a 16x16LED Chinese character display bar based on single-chip dynamic scanning control, briefly analyzes the principle of Chinese character display, and studies how the LED displ...[Details]
Problems such as the depletion of natural resources, air pollution, traffic congestion, and rising fossil fuel prices have forced societies and individuals to seek alternative means of transportati...[Details]
Motors, especially those with brushes, generate a lot of noise. This noise must be dealt with if the appliance is to meet the requirements of EMC standards. The means to solve EMC are nothing more ...[Details]
Motors are important products that convert electrical energy into mechanical energy to achieve automation, and they are widely used in industrial control, medical electronics, white a...[Details]