EEWORLDEEWORLDEEWORLD

Part Number

Search

2646LPAB17/101L12V

Description
Rocker Switch, On-on, 10A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size333KB,8 Pages
ManufacturerAPEM
Download Datasheet Parametric View All

2646LPAB17/101L12V Overview

Rocker Switch, On-on, 10A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount

2646LPAB17/101L12V Parametric

Parameter NameAttribute value
Termination typeSCREW
Actuator colorWHITE
Actuator materialPOLYAMIDE
center contact materialSILVER
End contact materialSILVER
Shell materialPOLYAMIDE
Installation featuresPANEL MOUNT
surface mountNO
Actuator length0.394 inch
body width24.9936 mm
body height16.9926 mm
Body length or diameter32.004 mm
Terminal length0.437 inch
Contact (DC) maximum rated R load10A@24VDC
Contact functionON-ON
Maximum contact voltage (AC)250 V
Dielectric withstand voltage2500VRMS V
Insulation resistance1000000000 Ω
Switch typeROCKER SWITCH
Actuator typeROCKER
Other features12V FILAMENT LAMP
Contact (AC) maximum rated power R load0.16HP@250VAC
Contact (AC) maximum rated R load10A@250VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact resistance0.01 mΩ
Maximum contact voltage (DC)24 V
Electrical life10000 Cycle(s)
Maximum operating temperature85 °C
Minimum operating temperature-20 °C
Is SamacsysN
YTEOL8.89
Objectid313025516
Reach Compliance CodeCompliant
Country Of OriginUK
ECCN codeEAR99
2600 series
Power rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
Illuminated or non-illuminated
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max.
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
3.000 Vrms 50 Hz min. between terminals and metal panel
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA (double pole)
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL (double pole)
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +85°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-45
Well-known foreign-funded communications companies are recruiting software development engineers, protocol engineers, algorithm analysis and implementation engineers, and algorithm analysis system simulation engineers!!!
[b]Wireless Product Software Development Engineer[/b] Job Description: Responsible for the design, coding, debugging, unit testing and other work of wireless product software modules, participate in r...
rto.wang Embedded System
A 17-year-old boy dropped out of elementary school after three years of school and was sentenced to four years in prison for attacking an airline company's system! He claimed that his girlfriend was pregnant during the epidemic and he was under great pressure
“If you can’t buy a ticket back home, you’ll paralyze the airline system!” Unexpectedly, a 17-year-old boy (pseudonym Xiao Chen) was unable to buy a ticket back to China during the epidemic, so he imp...
赵玉田 Talking
How to simulate 4046 in PROTEL99
I would like to ask the experts: There is no CD4046 in the simulation library of PROTEL99. How to simulate 4046? Thank you!...
李维 Industrial Control Electronics
Newbie help~FPGA EP4CE6E22C8N + EPCS4S18 does not work properly
As a newbie, I would like to ask you a question: After I completed a circuit using an analog board + a dynamic board, I washed the circuit on a board. The board is back and can be burned, but the FPGA...
賴冠融 FPGA/CPLD
In IAR environment, if you want to download the protocol stack to RF-CC2430, how should you set it?
The download always fails. I don't know how to set the parameters in option? I would appreciate your advice!...
懒骨头 Embedded System
Urgently looking for a usable DXP2004
I downloaded a lot of DXP2004 from the Internet, but they all have some problems. I've been very anxious these two days. I hope someone who has some can pass them on to me. I'd be very grateful! wangl...
gyl52114 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 231  1417  2810  2701  2273  5  29  57  55  46 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号