LP9-11211D11

Description
Special Switch, 5A, 28VDC, Solder Terminal, Through Hole-straight
CategoryMechanical and electronic products    switch   
File Size1MB,2 Pages
ManufacturerOTTO
Websitehttp://www.ottoexcellence.com
Environmental Compliance
Download Datasheet Parametric View All

LP9-11211D11 Overview

Special Switch, 5A, 28VDC, Solder Terminal, Through Hole-straight

LP9-11211D11 Parametric

Parameter NameAttribute value
Is it Rohs certified?Yes
Is SamacsysN
Objectid315759933
Reach Compliance CodeUnknown
ECCN codeEAR99
Actuator angle
Actuator colorRED
Actuator stroke2.032 mm
Terminal materialSILVER
Actuator materialTHERMOPLASTIC
Casing type15/32-32
contact timeSNAP ACTION
illuminationLED
Installation featuresTHROUGH HOLE-STRAIGHT
surface mountNO
Terminal surfaceGold (Au)
Termination typeSOLDER
Actuator length0.27 inch
body height8.636 mm
Actuator typePUSHBUTTON
Contact (AC) maximum rated R load3A@115VAC
Maximum contact current (AC)3 A
Contact (DC) maximum rated R load5A@28VDC
Maximum contact voltage (AC)115 V
Dielectric withstand voltage1050VRMS V
Maximum contact current (DC)5 A
Maximum contact voltage (DC)28 V
JESD-609 codee4
Maximum operating temperature85 °C
Minimum operating temperature-55 °C
LP9
ILLUMINATED
PUSHBUTTONS
ILLUMINATED SEALED DOME PUSHBUTTONS
MOMENTARY ACTION COMMERCIAL GRADE LED ILLUMINATED & WATERTIGHT SEALED
The OTTO LP9 Lighted Dome series is a quality precision switch
designed for use in panels, control grips, instruments, heavy
equipment and other demanding applications where attractive,
rugged, lighted pushbutton switches are required.
The LP9 series offers a positive tactile feedback, signaling the
operator when the switch is operated with the added benefit
of reliable LED illumination. The LP9 series offers four button
versions; flush and raised profile with either a glossy or matte
finish. It also comes with a threaded case for hex nut mounting
while providing a short behind panel depth.
The LP9 series is constructed to meet IP68S watertight seal.
Expect 25,000 operations at full rated load of 5 amps resistive or
3 amps inductive; 500,000 operations at 500mA/200mA resistive.
The LP9 series are momentary snap-action double break
switches, available in standard and low operate forces.
The LED is available in five colors and has the ability to
accommodate 2 or 12VDC.
Flush Dome
Also available with
Raised Dome
Standard Characteristics/Ratings:
ELECTRICAL RATINGS:
Load
Resistive
Inductive
Resistive
Resistive
DWV
Low Level
Electrical Life:
5A
3A
500mA
200mA
10mA @ 30mV
See Rating Chart
Sea Level @ 28VDC or 115VAC, 60/400Hz
N.O./N.C.
Cycles
25,000
25,000
500,000
500,000
25,000
Operating Force
Standard
Standard
Standard
Low or Standard
1050Vrms through switch contacts only
Features:
• Watertight to IP68S
• LED lighted with the ability to accommodate
2 or 12VDC
• LED available in 6 colors
• Flush & raised button style
• Matte or glossy button finish
• Positive tactile feedback contact transfer
• Withstands extreme shock & vibration
• Short behind panel depth
• RoHS/WEEE/Reach compliant
LIGHTING:
Light Source Voltage (DC)
2
12
Mechanical Life:
Seal:
Operating Force:
Total Travel:
Overtravel:
1,000,000 cycles
IP68S
1.7 +/- 0.5 lb. (standard force)
12 +/- 4 oz (low force)
0.080 inches max
0.010 inches min
Actual Voltage Nominal (DC)
2
13.5
Voltage Max (DC)
2.6
14.5
Operating Temp Range:
-55°C to +85°C
MATERIALS:
Case:
Button:
Terminals:
Mounting Hardware:
Thermoplastic
Thermoplastic
Silver with gold plate
Hex nut and lockwasher for round/threaded style case only
Panel gasket for snap-in style case only
LP9
Button Style*
1.
Flush
2.
Raised
3.
Flush Matte
4.
Raised Matte
X
X
Terminal Style
1.
Solder
2.
PC Pin
X
LP9 PART NUMBER CODE
X
X
Circuit Form
1.
N.O.
2.
N.C.
3.
2 Circuit
X
X
Case Color
1.
Red
2.
Black
3.
Orange**
4.
Yellow**
5.
Green**
6.
Blue**
7.
Violet**
8.
Gray**
9.
White
X
Button Color
1.
Red
2.
Black
3.
Orange
4.
Yellow
5.
Green
6.
Blue
7.
Violet
8.
Gray
9.
White
Case Style*
1.
Round/Threaded
2.
Snap-In
Operating Force
1.
Standard
Snap-Action
2.
Low Force
Snap-Action
Light Source
A.
2V Red LED
B.
2V Green LED
C.
2V Amber LED
D.
2V Blue LED
E.
2V White LED
F.
12V Red LED
G.
12V Green LED
H.
12V Amber LED
J.
12V Blue LED
K.
12V White LED
L.
2V Deep Green LED
M.
12V Deep Green LED
* Button and case will be of the same texture.
For all mixed gloss/matte combination options, contact factory.
** For minimum requirement, contact factory.
108
OTTO Full Line Catalog
Specifications Subject To Change Without Notice
Is there a light-sensing panel like a solar panel?
Is there a light sensor like a solar panel? Or, can a solar panel be used as a sensor? Can anyone help me answer this question? Thank you very much!...
逆流的鱼 Energy Infrastructure?
Why can't the CCR1 counting interrupt of this old program continue?
The following program can make the LED flash by using CCR0 counting. Why can't the interrupt continue to flash when CCR1 counting is changed? :Sad:!#include "msp430x14x.h"void main(void){ WDTCTL=WDTPW...
零晨 Microcontroller MCU
Commonly used alarm host programming manual (complete)
Commonly used alarm host programming manual (full) Saier community. [url=http://bbs.shejis.com/viewthread.php?tid=1539884&fromuid=58271][color=#261cdc][/color][/url][url=http://bbs.shejis.com/viewthre...
kandy2059 Industrial Control Electronics
Help: When my 51 is reset, does the CPLD need to be reset? Thank you!
I have a question; my program can be reset by power on, but not by manual reset (it can be reset, but the program does not run correctly after reset) (CPLD is not reset when 51 is reset manually) Does...
yy0216 Embedded System
Can someone explain to me why the crystal oscillator on the TI simulator on the group-purchased board is 12M?
Today I was bored and looked at the circuit diagram in the official manual of the group-purchased board. I found that the 1612 was connected to a 12M crystal! I remember that the maximum connection of...
clogord TI Technology Forum
Fiber optic transceiver installation and common faults
Installation of optical transceivers and common faults 1. A brief introduction to the installation of optical transceivers 1. First, check whether the indicator lights of the optical transceiver or op...
liudong2008lldd RF/Wirelessly

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1077  1365  2455  2351  832  22  28  50  48  17 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号