All technical data relates to an ambient temperature of +25°C. Capacitance and DF are measured at 120Hz, 0.5V RMS with a maximum DC bias of 2.2 volts. DCL is measured at rated voltage after 5 minutes.
NOTE: AVX reserves the right to supply a higher voltage rating or tighter tolerance part in the same case size, to the same reliability standards.
10
The Important Information/Disclaimer is incorporated in the catalog where these specifications came from or
available online at www.avx.com/disclaimer/ by reference and should be reviewed in full before placing any order.
062620
TAZ SERIES
CWR09 - MIL-PRF-55365/4 Established Reliability,
COTS-Plus & Space Level
RATING & PART NUMBER REFERENCE
CWR09 P/N
CWR09K^225*@+
CWR09K^475*@+
CWR09K^685*@+
CWR09K^106*@+
CWR09K^156*@+
CWR09M^224*@+
CWR09M^474*@+
CWR09M^684*@+
CWR09M^105*@+
CWR09M^155*@+
CWR09M^335*@+
CWR09M^475*@+
CWR09M^685*@+
CWR09N^104*@+
CWR09N^154*@+
CWR09N^224*@+
CWR09N^334*@+
CWR09N^474*@+
CWR09N^684*@+
CWR09N^105*@+
CWR09N^155*@+
CWR09N^225*@+
CWR09N^335*@+
CWR09N^475*@+
AVX MIL & COTS-Plus P/N
TAZ E 225 * 025 C
#
@
0 ^ ++
TAZ F 475 * 025 C
#
@
0 ^ ++
TAZ G 685 * 025 C
#
@
0 ^ ++
TAZ G 106 * 025 C
#
@
0 ^ ++
TAZ H 156 * 025 C
#
@
0 ^ ++
TAZ A 224 * 035 C #
@
0 ^ ++
TAZ B 474 * 035 C #
@
0 ^ ++
TAZ C 684 * 035 C #
@
0 ^ ++
TAZ D 105 * 035 C #
@
0 ^ ++
TAZ E 155 * 035 C #
@
0 ^ ++
TAZ F 335 * 035 C #
@
0 ^ ++
TAZ G 475 * 035 C #
@
0 ^ ++
TAZ H 685 * 035 C #
@
0 ^ ++
TAZ A 104 * 050 C #
@
0 ^ ++
TAZ A 154 * 050 C #
@
0 ^ ++
TAZ B 224 * 050 C #
@
0 ^ ++
TAZ B 334 * 050 C #
@
0 ^ ++
TAZ C 474 * 050 C #
@
0 ^ ++
TAZ D 684 * 050 C #
@
0 ^ ++
TAZ E 105 * 050 C #
@
0 ^ ++
TAZ F 155 * 050 C #
@
0 ^ ++
TAZ F 225 * 050 C #
@
0 ^ ++
TAZ G 335 * 050 C #
@
0 ^ ++
TAZ H 475 * 050 C #
@
0 ^ ++
AVX SRC9000 P/N
TAZ E 225 * 025 C
L
@
9 ^ ++
TAZ F 475 * 025 C
L
@
9 ^ ++
TAZ G 685 * 025 C
L
@
9 ^ ++
TAZ G 106 * 025 C
L
@
9 ^ ++
TAZ H 156 * 025 C
L
@
9 ^ ++
TAZ A 224 * 035 C L
@
9 ^ ++
TAZ B 474 * 035 C L
@
9 ^ ++
TAZ C 684 * 035 C L
@
9 ^ ++
TAZ D 105 * 035 C L
@
9 ^ ++
TAZ E 155 * 035 C L
@
9 ^ ++
TAZ F 335 * 035 C L
@
9 ^ ++
TAZ G 475 * 035 C L
@
9 ^ ++
TAZ H 685 * 035 C L
@
9 ^ ++
TAZ A 104 * 050 C L
@
9 ^ ++
TAZ A 154 * 050 C L
@
9 ^ ++
TAZ B 224 * 050 C L
@
9 ^ ++
TAZ B 334 * 050 C L
@
9 ^ ++
TAZ C 474 * 050 C L
@
9 ^ ++
TAZ D 684 * 050 C L
@
9 ^ ++
TAZ E 105 * 050 C L
@
9 ^ ++
TAZ F 155 * 050 C L
@
9 ^ ++
TAZ F 225 * 050 C L
@
9 ^ ++
TAZ G 335 * 050 C L
@
9 ^ ++
TAZ H 475 * 050 C L
@
9 ^ ++
Case
E
F
G
G
H
A
B
C
D
E
F
G
H
A
A
B
B
C
D
E
F
F
G
H
Parametric Specifications by Rating per MIL-PRF-55365/4
All technical data relates to an ambient temperature of +25°C. Capacitance and DF are measured at 120Hz, 0.5V RMS with a maximum DC bias of 2.2 volts. DCL is measured at rated voltage after 5 minutes.
NOTE: AVX reserves the right to supply a higher voltage rating or tighter tolerance part in the same case size, to the same reliability standards.
The Important Information/Disclaimer is incorporated in the catalog where these specifications came from or
available online at www.avx.com/disclaimer/ by reference and should be reviewed in full before placing any order.
062620
11
TAZ SERIES
CWR19 - MIL-PRF-55365/11 Established Reliability,
COTS-Plus & Space Level
An extended range of capacitor ratings beyond
CWR09 that is fully qualified to MIL-PRF-55365/11,
this series represents the most flexible of surface
mount form factors, offering nine case sizes (the
original A through H of CWR09) and adds the new
X case size.
The molded body / compliant termination
construction ensures no TCE mismatch with any
substrate. This construction is compatible with
a wide range of SMT board assembly processes
including convection reflow solder, conductive epoxy
or compression bonding techniques. The parts also
carry full polarity and capacitance / voltage marking.
The four smaller cases are characterized by their low
profile construction, with the A case being the world’s
smallest molded military tantalum chip.
The series is qualified to MIL-PRF-55365 Weibull
“B”, “C”, “D” and “T” levels, with all surge options
(“A”, “B” & “C”) available.
For Space Level applications, AVX SRC 9000
qualification is recommended (see ratings table
for part number availability).
There are four termination finishes available:
solder plated, fused solder plated, hot solder
dipped and gold plated (these are “H”, “K”, “C” and
“B” termination, respectively, per MIL-PRF-55365).
In addition, the molding compound has been
selected to meet the requirements of UL94V-0
(Flame Retardancy) and outgassing requirements
of ASTM E-595.
For moisture sensitivity levels please refer to the High
Reliability Tantalum MSL section located in the back
of the High Reliability Tantalum Catalog.
CASE DIMENSIONS:
Case
Code
Length (L)
±0.38
(0.015)
Width (W)
±0.38
(0.015)
Height (H)
±0.38
(0.015)
Term. Width
(W
1
)
1.27±0.13
(0.050±0.005)
1.27±0.13
(0.050±0.005)
1.27±0.13
(0.050±0.005)
2.41+0.13/-0.25
(0.095+0.005/-0.010)
2.41+0.13/-0.25
(0.095+0.005/-0.010)
3.30±0.13
(0.130±0.005)
2.67±0.13
(0.105±0.005)
3.68+0.13/-0.51
(0.145+0.005/-0.020)
3.05±0.13
(0.120±0.005)
millimeters (inches)
Term. Length (A)
+0.25/-0.13
(+0.010/-0.005)
0.76 (0.030)
0.76 (0.030)
0.76 (0.030)
0.76 (0.030)
0.76 (0.030)
0.76 (0.030)
1.27 (0.050)
1.27 (0.050)
1.19 (0.047)
S min
0.38 (0.015)
1.65 (0.065)
2.92 (0.115)
1.65 (0.065)
2.92 (0.115)
3.43 (0.135)
3.56 (0.140)
4.06 (0.160)
3.67 (0.144)
Typical
Weight (g)
0.016
0.025
0.035
0.045
0.065
0.125
0.205
0.335
0.420
MARKING
(White marking on black body)
Polarity Stripe (+)
Capacitance Code
Rated Voltage
A
B
C
D
E
F
G
H
X
2.54 (0.100) 1.27 (0.050) 1.27 (0.050)
3.81 (0.150) 1.27 (0.050) 1.27 (0.050)
5.08 (0.200) 1.27 (0.050) 1.27 (0.050)
3.81 (0.150) 2.54 (0.100) 1.27 (0.050)
5.08 (0.200) 2.54 (0.100) 1.27 (0.050)
5.59 (0.220) 3.43 (0.135) 1.78 (0.070)
6.73 (0.265) 2.79 (0.110)
7.24 (0.285) 3.81 (0.150)
6.93 (0.273) 5.41 (0.213)
2.79 (0.110)
2.79 (0.110)
2.74 (0.108)
CWR19-MIL-PRF 55365/11
CAPACITANCE AND RATED VOLTAGE, V
R
(VOLTAGE CODE) RANGE (LETTER DENOTES CASE SIZE)
Capacitance
µF
0.33
0.47
0.68
1.0
1.5
2.2
3.3
4.7
6.8
10
15
22
33
47
68
100
150
220
330
Code
334
474
684
105
155
225
335
475
685
106
156
226
336
476
686
107
157
227
337
4V (C)
6V (D)
Rated Voltage DC (V
R
) at 85ºC
10V (F)
15V (H)
20V (J)
25V (K)
A
B
D
E
F
G
G/H
H/X
G
H
X
35V (M)
A
A
A
A
B
B
B/D
D/E
E
E
F
G
H
H
A
A
B
B
B/D/E
D/E
E
F
F/G
G
G
H
H
A
A
B/C
B/C/D
B/C/D/E
D/E
E
F
F/G
G
G/H
H/X
H
A
A
A
B
B/C/D
D/E
D/E
E/F
F
F/G
G/H
G/H
H
A
A
B
B
D
E
E
E/F
F
G
H
H/X
12
The Important Information/Disclaimer is incorporated in the catalog where these specifications came from or
available online at www.avx.com/disclaimer/ by reference and should be reviewed in full before placing any order.
Please note that our OLED modules now have three options: dual color, pure blue, and pure white. For details, please see my shop: http://shop62103354.taobao.com/
OLED video address: http://v.youku.com...
The development of semiconductor LED industry presents three major characteristics2004-11-19 China Electronics News Since the use of semiconductor LED (light-emitting diode) lighting has the advantag...
I just came into contact with 51. It is generally believed that the timer is implemented in an interrupt manner. Yesterday I saw an example in a book: Org 0000h; Ljmp main; Org 0030h; Main:mov tmod,#0...
Company Name: Carrier Access Company Website: http://www.carrieraccess.com Email: lshi@carrieraccess.com, please indicate the source of your resume Work Location: Shanghai Foreign Language Requirement...
Step 1: Upgrade PB5.0 to the 2008 annual upgrade package. Based on the ARMSYS2410.pbxml provided by the Youlong 2410 development board data, add .net compact framework 2.0 to OS, compile successfully,...
Calibrators are widely used in university experiments. Among them, there are two experiments in nuclear physics experiments in modern physics experiments (GM counter and β absorption) that require ...[Details]
Although improper medical device product design is not always associated with medical device-related errors. Studies of users have shown that lack of adequate training accounts for 70% to 90% of suc...[Details]
The latest C language tools allow you to quickly complete the design of algorithm-intensive applications even if you are not proficient in hardware development.
Hardware designers have b...[Details]
Medical and industrial applications often require isolation voltages of 2500Vac or higher for patient and equipment operator safety. The isolation barrier must not only transmit power to the sensin...[Details]
For more than 10 years, analog-to-digital converters (ADCs) have been widely used in industrial process control, medical instruments, communication systems, radar and other products as a booster of in...[Details]
Basic principles of simulation
Simulation is a technology used in the field of embedded system development. It can bring system developers the controllability and visibility needed to integra...[Details]
1 Introduction
The intelligent meter reading system is a system that reads the data of multiple user meters in a centralized manner through the transmission media by the master station. It...[Details]
introduction
In engineering practice, ultrasonic waves are often used to measure distances because of their strong directivity, slow energy consumption, and long propagation distance in th...[Details]
According to In-Stat/MDR, the number of mobile phones with Bluetooth capabilities will reach at least 300 million by 2005. One of the clear evidences of the increasing adoption of Bluetooth is that...[Details]
Abstract: This paper introduces the origin and new features of MP4, and introduces the core audio compression technology MPEG-2 AAC (Advanced Audio Coding) based on MP4. Finally, it briefly summari...[Details]
IPTV (Internet Protocol TV or Interactive Personal TV), also known as interactive network television, is a new technology that uses broadband network infrastructure, takes home televisions or comp...[Details]
A correct circuit design cannot be manufactured 100% correctly when it is taken to the factory for manufacturing. It will always be affected by various uncertainties, such as deviations in manufact...[Details]
Introduction
High voltage power supply is an indispensable part of nuclear radiation detection instrument, which supplies high voltage to nuclear radiation detection devices (such as prop...[Details]
Multiple Input and Multiple Output (MIMO) technology is arguably the next most important development in wireless communication technology since the advent of digital communications. Many new wir...[Details]
1 Introduction to suction laminating machine
Suction laminating machine is a kind of woodworking machinery, which can realize the laminating function of wood boards and other materials. It i...[Details]