T429D685K015CBTLVL7005

Description
Tantalum Capacitor, Polarized, Tantalum (dry/solid), 15V, 10% +Tol, 10% -Tol, 6.8uF, 1510,
CategoryPassive components    capacitor   
File Size2MB,20 Pages
ManufacturerKEMET
Websitehttp://www.kemet.com
Environmental Compliance
Download Datasheet Parametric View All

T429D685K015CBTLVL7005 Overview

Tantalum Capacitor, Polarized, Tantalum (dry/solid), 15V, 10% +Tol, 10% -Tol, 6.8uF, 1510,

T429D685K015CBTLVL7005 Parametric

Parameter NameAttribute value
JESD-609 codee4
GuidelineMIL-PRF-55365/11
Number of terminals2
Package formSMT
surface mountYES
Terminal surfaceGold (Au)
Terminal shapeJ BEND
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Is it Rohs certified?Yes
Objectid7058678934
Reach Compliance CodeCompliant
Country Of OriginMexico
YTEOL7.48
package instruction, 1510
ECCN codeEAR99
Is SamacsysN
ESR2000 mΩ
negative tolerance10%
polarityPOLARIZED
Rated (DC) voltage (URdc)15 V
capacitance6.8 µF
Capacitor typeTANTALUM CAPACITOR
dielectric materialsTANTALUM (DRY/SOLID)
Installation featuresSURFACE MOUNT
positive tolerance10%
size code1510
length3.81 mm
width2.54 mm
high1.27 mm
Tantalum Surface Mount Capacitors – MIL–PRF (CWR Style)
T429 Series MIL–PRF–55365/11 (CWR29 Style)
Overview
The KEMET T429 Series is approved to MIL–PRF–55365/11
(CWR29 Style) with Weibull failure rates of B level (0.1%
failures per 1,000 hours), C level (0.01% failures per 1,000
hours), D level (0.001% failures per 1,000 hours), or T level
(0.01% failures per 1,000 hours, Option C surge current,
DPA, Radiographic inspection, 100% visual inspection, DCL and
ESR measurements within +3 standard deviations, and Group C
inspection). This CWR29 product is a precision-molded device
with compliant terminations and indelible laser marking. Tape and
reeling per EIA 481 is standard.
Benefits
Established reliability options
Taped and reeled per EIA 481
Symmetrical, compliant terminations
Laser-marked case
100% surge current test available on all case sizes
Qualified to MIL–PRF–55365/11 (CWR29 Style)
Termination options B, C, H, K
Weibull failure options B, C, D, and T
Exponential failure rates M, P, R, S
Voltage rating of 4 – 50 VDC
Operating temperature range of −55˚C to +125˚C
Click image above for interactive 3D content
Open PDF in Adobe Reader for full functionality
Applications
Typical applications include decoupling and filtering in military and aerospace applications requiring CWR29 devices.
Environmental Compliance
RoHS Compliant (6/6) according to Directive 2002/95/EC when ordered with 100% Sn Solder.
K-SIM
For a detailed analysis of specific part numbers, please visit ksim.kemet.com to access KEMET’s K-SIM software. KEMET K-SIM is
designed to simulate behavior of components with respect to frequency, ambient temperature, and DC bias levels.
One world. One KEMET
© KEMET Electronics Corporation • P.O. Box 5928 • Greenville, SC 29606 (864) 963-6300 • www.kemet.com
T2003_T429 • 2/18/2016
1
[Help] I have two questions
First: The address of the first instruction executed after 430 reset or power on is 1100h, but I wrote a small assembly program. Why is the address of the first instruction of this program 0f000h? I t...
keane Microcontroller MCU
Low Power RF Low Noise Amplifier
In portable communication devices, such as cellular phones and digital cordless phones, high-frequency, low-power, low-noise amplifiers are needed to amplify . The GSM mobile communication RF receivin...
JasonYoo RF/Wirelessly
[NXP Rapid IoT Review] +1. Data preparation, first look at NXP Rapid IoT
[i=s]This post was last edited by chrisrh on 2018-12-29 18:32[/i] I received the Rapid IoT last night, so I couldn't wait to open it and try it out. It's full of functions and applications, and I was ...
chrisrh RF/Wirelessly
CLOCK_DEDICATED_ROUTE constraint applies
The Vivado tool usually automatically identifies the clock network in the design during compilation and assigns it to the dedicated clock placement and routing resources. By setting the CLOCK_DEDICATE...
ove学习使我快乐 FPGA/CPLD
EEWORLD University Hall ---- Automatic Control Principles Shiqun
Principles of Automatic Control Shiqun : https://training.eeworld.com.cn/course/5219The most detailed, practical and postgraduate entrance examination standard "Automatic Control Principles (including...
JFET Industrial Control Electronics
Noise Interference Problems in Industrial Measurement
Q: What are the most likely problems I will encounter when instrumenting an industrial system ? A: According to customers of ADI 's I/O Subsystems (IOS) division , the following five problems are most...
fighting Test/Measurement

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2272  2010  134  429  1274  46  41  3  9  26 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号