EEWORLDEEWORLDEEWORLD

Part Number

Search

2646LPC83600L6V

Description
Rocker Switch, On-on, 10A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size333KB,8 Pages
ManufacturerAPEM
Download Datasheet Parametric View All

2646LPC83600L6V Overview

Rocker Switch, On-on, 10A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount

2646LPC83600L6V Parametric

Parameter NameAttribute value
ECCN codeEAR99
Is SamacsysN
YTEOL8.89
Objectid313030073
Reach Compliance CodeCompliant
Country Of OriginUK
Actuator colorRED
Actuator materialPOLYAMIDE
center contact materialCOPPER
Installation featuresPANEL MOUNT
surface mountNO
Termination typeSCREW
Center contact platingSILVER
End contact materialCOPPER
Shell materialPOLYAMIDE
Actuator length0.394 inch
body width24.9936 mm
body height16.9926 mm
Body length or diameter32.004 mm
Terminal length0.437 inch
Contact functionON-ON
Dielectric withstand voltage2500VRMS V
Actuator typeROCKER
Other features6V FILAMENT LAMP
Contact (AC) maximum rated power R load0.16HP@250VAC
Contact (DC) maximum rated R load10A@24VDC
Switch typeROCKER SWITCH
Contact (AC) maximum rated R load10A@250VAC
Maximum contact current (AC)10 A
Maximum contact voltage (AC)250 V
Insulation resistance1000000000 Ω
Maximum contact current (DC)10 A
Contact resistance0.01 mΩ
Maximum contact voltage (DC)24 V
Electrical life10000 Cycle(s)
End contact platingSILVER
Maximum operating temperature55 °C
Minimum operating temperature-10 °C
2600 series
Power rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
Illuminated or non-illuminated
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max.
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
3.000 Vrms 50 Hz min. between terminals and metal panel
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA (double pole)
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL (double pole)
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +85°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-45
How to deal with the obvious lag when using ScrollWindowEx?
When dragging the scroll bar, the page has a ghosting effect. How should I deal with it? Even if there are many files in the system, there is no such phenomenon. ? void C2MSetting::OnVScroll(UINT nSBC...
lzg2002nian Embedded System
MSP430F5438a uses BSL downloader to download program
When using BSL Downloader to download the program for MSP430F5438a, an error "test file exceeds the size limit" appears. Please help me take a look. Thank you....
栗子lanya Microcontroller MCU
[Word format] LabVIEW training materials, several relatively complete training materials, all in Chinese
The decompression password is: 129258 The following is the directory: Steps to display a digital signal.doc Data module.doc Analog input signal connection.doc Design topic.doc Formula node syntax.doc ...
lorant Test/Measurement
DXP schematic copied to WORD does not display completely
Please help me! I copied the schematic I drew in DXP to WORD format, but it is not fully displayed when copied to WORD. I need to copy the schematic. Is there any way to copy the schematic completely?...
foster Embedded System
Smurf Lecture 2: Introduction to STM32 firmware and MDK usage
This issue recorded a video of "Introduction to STM32 Firmware and Introduction to MDK Usage", I hope it will be helpful for stm32 beginners!...
飞嵌电子 stm32/stm8
About TI MCU selection
Which TI MCU with CAN has the lowest cost? Is there a big difference between the peripherals of MSP430 and C2000? - refers to the structure and programming method eeworldpostqq...
Zero Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2566  2615  2347  2561  1976  52  53  48  40  56 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号