EEWORLDEEWORLDEEWORLD

Part Number

Search

U538A-020014-035BG

Description
Peizoresistive Sensor, 0Psi Min, 500Psi Max, 0.1%, 1-6V, Cylindrical
CategoryThe sensor    Sensor/transducer   
File Size319KB,8 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Environmental Compliance
Download Datasheet Parametric View All

U538A-020014-035BG Overview

Peizoresistive Sensor, 0Psi Min, 500Psi Max, 0.1%, 1-6V, Cylindrical

U538A-020014-035BG Parametric

Parameter NameAttribute value
Installation featuresUNSPECIFIED MOUNT
Package Shape/FormCYLINDRICAL
Termination typeCONNECTOR
Maximum operating temperature125 °C
Minimum operating temperature-40 °C
Objectid145065941697
Reach Compliance CodeUnknown
Country Of OriginMainland China
Is SamacsysN
YTEOL7.73
Is it Rohs certified?Yes
Output range1-6V
Maximum pressure range500 Psi
Minimum pressure range
Pressure sensing modeGAUGE
Sensor/Transducer TypePRESSURE SENSOR,PIEZORESISTIVE
surface mountNO
Maximum accuracy(%)0.1%
shellSTAINLESS STEEL
Other featuresPort Height = 12.9 MM
Maximum working current5 mA
Output typeVOLTAGE OUTPUT
port typeTHREADED
Maximum supply voltage30 V
Minimum supply voltage8 V
body height79.1 mm
Body length or diameter24 mm
U5300
Industrial Pressure Transducer
SPECIFICATIONS
Superior Accuracy and Total Error Band
Instrument Grade and Compact
Variety of Pressure Ports and Electrical Configurations
Optional Stainless Steel Snubber
CE Compliant and Weatherproof
UL Certified
Gage, Sealed, Absolute, Compound
Expedite Configurations Available (10 Days)
FEATURES
Heavy Industrial CE Approval
10 V/m EMI Protection
Reverse Polarity Protection on Input
Short Circuit Protection on Output
±0.1% Accuracy
±0.5% Total Error Band
Compact Outline
-40°C to +125°C Operating Temperature
Weatherproof
The instrument grade U5300
pressure transducers from the UltraStable line
of MEAS, with their modular design, offer maximum flexibility for different
configurations. This latest series features superior accuracy and total error
band for demanding commercial and heavy industrial applications. This
series is suitable for measurement of liquid or gas pressure, even for difficult
media such as contaminated water, steam, and mildly corrosive fluids.
The wetted material is made of 316L stainless steel and the transducer’s
durability is excellent with no organics exposed to the pressure media. The
U5300 is weatherproof and exceeds the latest heavy industrial CE
requirements including surge protection. The circuit is protected from reverse
wiring at input and short circuit at output.
This product is geared to the OEM customer for low to mid volumes. MEAS
stands ready to provide a custom design of the U5300 where the volume and
application warrants. Additional configurations not listed are either available
or possible. Please inquire for further information.
APPLICATIONS
Military/Aerospace Test Stands
Automotive Test Stands
Calibration Equipment
High Accuracy Applications
Stationary Motor Fuel Control
High End Industrial Machinery
SENSOR SOLUTIONS
///U5300
10/2021
Page 1
Share CCS7.3 installation steps
[size=4]1. First, go to the TI official website to download the latest CCS7.3. [/size] [size=4]2. After the download is complete, double-click CCS_SETUP.EXE to install. Be careful not to have Chinese ...
Aguilera DSP and ARM Processors
spi driver 74hc595 problem
I use spi to drive 74hc595. 595 is connected to a common anode digital tube. When I use ckp=1//high level when idle cke=1//send data from low level to high level. The digital tube displays fine. When ...
king3306 Microchip MCU
Please ask the moderator again
Moderator, I am so confused about FSMC. I wonder if there is any information.Now the question is:How to determine the connection method of the 4 chip selects NE1~4 in bank1 of FSMC? For example, why s...
calvin83 stm32/stm8
Talking about WEBENCH, it is not just an event
Most of the brothers in the forum may know the WEBENCH tool through activities. I have been in contact with it for a long time. Because I have been using this tool since TI acquired National Semicondu...
starcool Analogue and Mixed Signal
Common Problems in PCB Circuit Layout Design
Question 2: What is the difference between wires, flying leads and networks?   Answer: Wires are also called copper film routing, or simply wires. They are used to connect various solder joints and ar...
fighting PCB Design
MSP430 MCU Development Record (4)
[b][color=#5E7384]This content is originally created by EEWORLD forum user [size=3]tiankai001[/size]. If you need to reprint or use it for commercial purposes, you must obtain the author's consent and...
tiankai001 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1365  127  778  123  2121  28  3  16  43  2 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号