Part Number

Search

3960IDC-07TB22-L

Description
Board Connector, 7 Contact(s), 1 Row(s), Female, 0.156 inch Pitch, IDC Terminal, Locking, Black Insulator
CategoryThe connector    The connector   
File Size674KB,1 Pages
ManufacturerRatioplast Electronics
Environmental Compliance
Download Datasheet Parametric View All

3960IDC-07TB22-L Overview

Board Connector, 7 Contact(s), 1 Row(s), Female, 0.156 inch Pitch, IDC Terminal, Locking, Black Insulator

3960IDC-07TB22-L Parametric

Parameter NameAttribute value
Contact completed and terminatedTIN
contact modeRECTANGULAR
Contact styleSQ PIN-SKT
Plug contact pitch0.156 inch
Mixed contactsNO
Installation option 1LOCKING
Insulator colorBLACK
Number of connectorsONE
Termination typeIDC
Dielectric withstand voltage1500VAC V
Filter functionNO
Insulation resistance1000000000 Ω
polarization keyPOLARIZED HOUSING
Maximum wire diameter22 AWG
Maximum operating temperature85 °C
Minimum operating temperature-25 °C
GuidelineUL
Is it Rohs certified?Yes
Objectid308893388
Reach Compliance CodeCompliant
Country Of OriginGermany
ECCN codeEAR99
Is SamacsysN
body width0.336 inch
subject depth0.772 inch
body length1.091 inch
Contact to complete cooperationSN
Contact point genderFEMALE
insulator materialPOLYAMIDE
Rated current (signal)5 A
Connector typeBOARD CONNECTOR
Installation typeCABLE
Number of rows loaded1
Total number of contacts7
Contact resistance10 mΩ
Ratioplast-Electronics H.Wiedemann GmbH
Jockweg 66, D-32312 Lübbecke
Tel:+49 (0) 5741 23661-0
Fax:+49 (0) 5741 23661-20
Ratioplast-Electronics
3.96mm Housing IDC Type & Cover
Current Rating: 5A AC,DC
Voltage Rating: 250V AC,DC
Temperature Range: -25°C to +85°C
Contact Resistance: 10mΩ Max
Insulation Resistance: 1000M
Ω
Min
Withstanding Voltage: 1500V AC/minute
Material: Nylon 66,UL94V-2
Specifications
No. of
Contacts
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
Dimensions
A
B
3.96
7.92
11.88
15.84
19.80
23.76
27.72
31.68
35.64
39.60
43.56
47.52
51.48
55.44
59.40
6.336
67.32
71.28
75.24
79.20
83.16
87.12
91.08
95.04
7.92
11.88
15.84
19.80
23.76
27.72
31.68
35.64
39.60
43.56
47.52
51.48
55.44
59.40
63.36
67.32
71.28
75.24
79.20
83.16
87.12
91.08
95.04
99.00
ORDER INFORMATION
3 9 6 0
Standard Recommend
T:Tin Plated
G:Gold Flash
GA:5u"
GB:10u"
GC:20u"
GD:30u"
S:Selective
SA:5u"
SB:10u"
SC:20u"
SD:30u"
W:Nylon natural
B:Black insulator
U:Blue insulator
R:Red insulator
G:Green insulator
I D C - X X
X
X
X
-
L
No. of contacts per row
(02~25)
18:18 AWG
20:20 AWG
22:22 AWG
24:24 AWG
26:26 AWG
L:RoHS + Nylon 66
COVER
Part No.:3960IDC-CXX-L
www.amtek-co.com.tw
www.amtek-co.com.tw
www.ratioplast.com
IIC program instance simulation does not respond
#include// Header file containing 51 MCU register definitions #include//Header file containing _nop_() function definition #define OP_READ 0xa1 // Device address and read operation, 0xa1 is 1010 0001B...
XCDZZR 51mcu
Update on Bluetooth Low Energy connection parameters
First of all, it should be clear that the connection parameters are determined by the host, and the slave can initiate a request to update the connection parameters. The host can directly send the con...
Jacktang Wireless Connectivity
Quiz draw: PlayerUnknown's Battlegrounds, challenge TI automotive technology solutions and win prizes
TI's automotive technology solutions theme event is back again. You can learn about the four major automotive electronics solutions: HEV/EV and powertrain, body electronics and lighting, infotainment ...
EEWORLD社区 Automotive Electronics
Asking for help on client issues
Hello everyone, I synthesized a TCP client example based on the examples on the forum. After downloading the program, I can ping it, but when I use the TCP server test program in the program to connec...
straw Microcontroller MCU
Design and Implementation of MPEG4 Encoder Based on TMS320DM642
[align=center][font=][b][size=7][size=25px][align=left]In recent years, with the development of network and multimedia technology, the importance and demand of video information communication have inc...
pony18 Embedded System
Do I need to configure the Include directory and import lib files every time I create a new project? Is there any way to save time?
Do I need to configure the Include directory and import lib files every time I create a new project? Is there any way to save it or save it as a template and create a new project from the template?...
经世致用 Microcontroller MCU

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1813  199  2503  1210  1350  37  5  51  25  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号