EEWORLDEEWORLDEEWORLD

Part Number

Search

2641LHCB3901L380V3

Description
Rocker Switch, On-off, 10A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size333KB,8 Pages
ManufacturerAPEM
Download Datasheet Parametric View All

2641LHCB3901L380V3 Overview

Rocker Switch, On-off, 10A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount

2641LHCB3901L380V3 Parametric

Parameter NameAttribute value
YTEOL8.89
Objectid312982754
Reach Compliance CodeCompliant
Country Of OriginUK
ECCN codeEAR99
Is SamacsysN
surface mountNO
Actuator colorORANGE
Actuator materialPOLYAMIDE
center contact materialCOPPER
Shell materialPOLYAMIDE
Installation featuresPANEL MOUNT
Center contact platingSILVER
End contact materialCOPPER
Termination typeSCREW
Actuator length0.354 inch
body width24.9936 mm
body height16.9926 mm
Body length or diameter32.004 mm
Terminal length0.437 inch
Contact (AC) maximum rated power R load0.16HP@250VAC
Contact (AC) maximum rated R load10A@250VAC
Contact (DC) maximum rated R load10A@24VDC
Contact functionON-OFF
Insulation resistance1000000000 Ω
Switch typeROCKER SWITCH
Actuator typeROCKER
Other features380VAC FLUORESCENT LAMP
Maximum contact current (AC)10 A
Maximum contact voltage (AC)250 V
Dielectric withstand voltage2500VRMS V
Electrical life10000 Cycle(s)
End contact platingSILVER
Maximum contact current (DC)10 A
Contact resistance0.01 mΩ
Maximum contact voltage (DC)24 V
Maximum operating temperature55 °C
Minimum operating temperature-10 °C
2600 series
Power rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
Illuminated or non-illuminated
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max.
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
3.000 Vrms 50 Hz min. between terminals and metal panel
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA (double pole)
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL (double pole)
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +85°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-45
Solution to PLC interference problem
The fault phenomenon is that the production line or equipment controlled by PLC often stops inexplicably. After checking many places, it has not been completely solved. After careful thinking and anal...
eeleader Industrial Control Electronics
A minimal system for making a F2812
I've been learning DSP recently, and I drew a minimum system. This is the second version. The first version tested the LED and it worked fine....
elvike Microcontroller MCU
How to accurately measure the active power consumption of the voltage winding of the electric energy meter
I would like to ask you a question, how can we accurately measure the active power consumption of the voltage winding of the electric energy meter?...
绿茶 Test/Measurement
ir2110 drives MOS tube. Help
ir2110 drives MOS tube, and requires Vcc to be connected to 24V battery. What should I do? 24V is too high. Is there any solution? Or use another driver chip? Please give me some advice....
电子小白abc Motor Drive Control(Motor Control)
Problems with displaying non-modal dialog boxes
A non-modal settings dialog is created in a dialog box, CProgressShow *pShow = new CProgressShow; if(NULL == pShow) { return; } pShow->Create(IDD_PROGRESS); pShow->ShowWindow(SW_SHOW); Only an outline...
syly Embedded System
Counting the number of people around you using ESP32
In this project, a simple people counter is made using ESP32 to count the number of people around you.ESP32 works in a promiscuous mode, this clever chip allows to capture IEEE802.11 network packets f...
dcexpert MicroPython Open Source section

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1568  1722  489  406  1122  32  35  10  9  23 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号